CURVATURE EFFECT QUANTIFICATION FOR IN-VIVO IR THERMOGRAPHY.

Tze-Yuan Cheng, Daxiang Deng, Cila Herman.   

Abstract

Medical Infrared (IR) Imaging has become an important diagnostic tool over recent years. However, one underlying problem in medical diagnostics is associated with accurate quantification of body surface temperatures. This problem is caused by the artifacts induced by the curvature of objects, which leads to inaccurate temperature mapping and biased diagnostic results. Therefore, in our study, an experiment-based analysis is conducted to address the curvature effects toward the 3D temperature reconstruction of the IR thermography image. For quantification purposes, an isothermal copper plate with flat surface, and a cylindrical metal container filled with water are imaged. For the flat surface, the tilting angle measured from camera axis was varied incrementally from 0° to 60 °, such that the effects of surface viewing angle and travel distance on the measured temperature can be explored. On the cylindrical curved surface, the points viewed from 0° to 90° with respect to the camera axis are simultaneously imaged at different temperature levels. The experimental data obtained for the flat surface indicate that both viewing angle and distance effects become noticeable for angles over 40 °. The travel distance contributes a minor change when compared with viewing angle. The experimental results from the curved surface indicate that the curvature effect becomes pronounced when the viewing angle is larger than 60 °. The measurement error on the curved surface is compared with the simulation using the non-dielectric model, and the normalized temperature difference relative to 0° viewing angle was analyzed at six temperature levels. These results indicate that the linear formula associated with directional emissivity is a reasonable approximation for the measurement error, and the normalized error curves change consistently with viewing angle at various temperatures. Therefore, the analysis in this study implies that the directional emissivity based on the non-dielectric model can be applied for the calibration of measurement error. The normalized error curve serves as a consistent basis to correct the measurement error due to curvature artifacts.

Entities:  

Keywords:  curvature artifacts; medical infrared thermography

Year:  2012        PMID: 24380084      PMCID: PMC3874242          DOI: 10.1115/IMECE2012-88105

Source DB:  PubMed          Journal:  Int Mech Eng Congress Expo


  3 in total

1.  Thermography of the curved living skin surface.

Authors:  C J Ash; E Gotti; C H Haik
Journal:  Mo Med       Date:  1987-11

2.  Apparent temperature degradation in thermograms of human anatomy viewed obliquely.

Authors:  D W Lewis; H O Goller; C D Teates
Journal:  Radiology       Date:  1973-01       Impact factor: 11.105

3.  The thermal scanning of a curved isothermal surface: implications for clinical thermography.

Authors:  D J Watmough; P W Fowler; R Oliver
Journal:  Phys Med Biol       Date:  1970-01       Impact factor: 3.609

  3 in total
  2 in total

Review 1.  Skin Cancer Detection Using Infrared Thermography: Measurement Setup, Procedure and Equipment.

Authors:  Jan Verstockt; Simon Verspeek; Filip Thiessen; Wiebren A Tjalma; Lieve Brochez; Gunther Steenackers
Journal:  Sensors (Basel)       Date:  2022-04-26       Impact factor: 3.847

2.  Thermographic Microstructure Monitoring in Electron Beam Additive Manufacturing.

Authors:  J Raplee; A Plotkowski; M M Kirka; R Dinwiddie; A Okello; R R Dehoff; S S Babu
Journal:  Sci Rep       Date:  2017-03-03       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.