| Literature DB >> 24379528 |
Jaya Shukla1, Rakhee Vatsa1, Nitasha Garg1, Priya Bhusari1, Ankit Watts1, Bhagwant R Mittal1.
Abstract
PURPOSE OF THE STUDY: To study quality control parameters of routinely prepared positron emission tomography (PET) radiopharmaceuticals.Entities:
Keywords: Gas chromatography; half-life; multichannel analyzer; pyrogen; sterility
Year: 2013 PMID: 24379528 PMCID: PMC3866663 DOI: 10.4103/0972-3919.121963
Source DB: PubMed Journal: Indian J Nucl Med ISSN: 0974-0244
Figure 1Graphical demonstration of time-activity curve on semilogthermic graph for determination of T1/2 of (a) F-18, (b) N-13, and (c) Ga-68
Figure 2Spectra obtained by using MCA (a) F-18 FDG (b) N-13 NH3
Figure 3Spectra of Ga-68 obtained by using MCA (a) After elution, (b) 24 h after elution
Figure 4Instant thin layer chromatograms of (a) fluorine-18 fluorodeoxyglucose, (b) Ga-68 DOTATATE, and (c) N-13 NH3
Figure 5Gas chromatograms of (a) ethanol and acetonitrile standard and (b) fluorine-18 fluorodeoxyglucosesample
Figure 6Gas chromatograms of (a) ethanol standard and (b) Ga-68 DOTATATE sample
Figure 7Showing chromatograms of (a) Kryptofix standard (0.22 mg/ml), (b) F-18 FDG samples, developed in methanol: ammonia (9:1, V/V) and exposed to iodine vapors; (c) Iodine chamber
Summary of quality control parameters of positron emission tomographyradiopharmaceuticals