Literature DB >> 24375896

High false-positive rate for monoclonal gammopathy using capillary electrophoresis (CAPILLARYS 2) alone.

Richard Sheng Poe Huang1, Deanna Alicia Oleske, Ashok Tholpady, Brian N Chang, Amitava Dasgupta, Andy Nguyen, Amer Wahed.   

Abstract

BACKGROUND: Capillary zone electrophoresis (CZE) is a newer method of performing serum protein electrophoresis and is considered to be faster and more efficient than agarose gel method. We decided to evaluate CZE as an efficient screening tool for monoclonal gammopathies, and we began recommending immunofixation studies in cases with such minor/subtle distortions to avoid missing monoclonal gammopathies.
METHODS: We evaluated 163 serum protein agarose gel electrophoresis (SPAGE) samples between October and November 2011, and 447 serum protein CZE (SPCZE) samples between January 2012 to February 2012 and August 2012 to September 2012.
RESULTS: Immunofixation studies were recommended in 51 of 163 cases (31.3%) performed by SPAGE, and in 274 of 447 cases (61.3%) performed by SPCZE. While using SPAGE, of the 51 cases recommended for immunofixation (24 were performed to date), six cases (25.0%) were positive for monoclonal gammopathy. In contrast, while using SPCZE, of the 274 cases recommended for immunofixation (118 were performed to date), 18 cases (15.2%) were positive for monoclonal gammopathy. Using the SPCZE method, of these 18 cases, five (27.8%) had minor/subtle distortions without obvious peaks. Our recommendation rate for immunofixation studies has thus almost doubled (61.3% vs. 31.3%) with the adoption of SPCZE. Yet, using SPCZE has not translated to detecting more cases of true monoclonal gammopathies.
CONCLUSION: Therefore, we conclude that there is a high false-positive rate for monoclonal gammopathy using CE alone.
© 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  agarose gel electrophoresis; capillary zone electrophoresis; immunofixation electrophoresis; monoclonal gammopathy

Mesh:

Substances:

Year:  2013        PMID: 24375896      PMCID: PMC6807474          DOI: 10.1002/jcla.21641

Source DB:  PubMed          Journal:  J Clin Lab Anal        ISSN: 0887-8013            Impact factor:   2.352


  17 in total

1.  [Serum protein electrophoresis: comparison of capillary zone electrophoresis Capillarys (Sebia) and agarose gel electrophoresis Hydrasys (Sebia)].

Authors:  B Lissoir; P Wallemacq; D Maisin
Journal:  Ann Biol Clin (Paris)       Date:  2003 Sep-Oct       Impact factor: 0.459

2.  Automated serum protein electrophoresis by Capillarys.

Authors:  Xavier Bossuyt; Bénédicte Lissoir; Godelieve Mariën; Diane Maisin; Jozef Vunckx; Norbert Blanckaert; Pierre Wallemacq
Journal:  Clin Chem Lab Med       Date:  2003-05       Impact factor: 3.694

Review 3.  Differential diagnosis of monoclonal gammopathies.

Authors:  R Alexanian; D Weber; F Liu
Journal:  Arch Pathol Lab Med       Date:  1999-02       Impact factor: 5.534

Review 4.  Understanding and interpreting serum protein electrophoresis.

Authors:  Theodore X O'Connell; Timothy J Horita; Barsam Kasravi
Journal:  Am Fam Physician       Date:  2005-01-01       Impact factor: 3.292

5.  Evaluation of a capillary zone electrophoresis system versus a conventional agarose gel system for routine serum protein separation and monoclonal component typing.

Authors:  L Roudiere; A M Boularan; A Bonardet; C Vallat; J P Cristol; A M Dupuy
Journal:  Clin Lab       Date:  2006       Impact factor: 1.138

6.  Serum and urine electrophoresis for detection and identification of monoclonal proteins.

Authors:  Margaret A Jenkins
Journal:  Clin Biochem Rev       Date:  2009-08

7.  Detection and identification of monoclonal gammopathies by capillary electrophoresis.

Authors:  Y Henskens; J de Winter; M Pekelharing; G Ponjee
Journal:  Clin Chem       Date:  1998-06       Impact factor: 8.327

8.  Detection and classification of paraproteins by capillary immunofixation/subtraction.

Authors:  X Bossuyt; A Bogaerts; G Schiettekatte; N Blanckaert
Journal:  Clin Chem       Date:  1998-04       Impact factor: 8.327

Review 9.  Capillary electrophoresis of serum proteins. Reproducibility, comparison with agarose gel electrophoresis and a review of the literature.

Authors:  P A Wijnen; M P van Dieijen-Visser
Journal:  Eur J Clin Chem Clin Biochem       Date:  1996-07

10.  Automated multicapillary electrophoresis for analysis of human serum proteins.

Authors:  Cécile Gay-Bellile; Djaouida Bengoufa; Pascal Houze; Didier Le Carrer; Mourad Benlakehal; Bernard Bousquet; Bernard Gourmel; Thierry Le Bricon
Journal:  Clin Chem       Date:  2003-11       Impact factor: 8.327

View more
  2 in total

1.  Inability to Measure M-Protein With Capillary Zone Electrophoresis (CAPPILLARYS 2) in Tracings With NonDiscernable Peaks.

Authors:  Richard S P Huang; Amitava Dasgupta; Andy N D Nguyen; Amer Wahed
Journal:  J Clin Lab Anal       Date:  2014-08-17       Impact factor: 2.352

2.  Development and validation of a deep learning-based protein electrophoresis classification algorithm.

Authors:  Nuri Lee; Seri Jeong; Kibum Jeon; Wonkeun Song; Min-Jeong Park
Journal:  PLoS One       Date:  2022-08-24       Impact factor: 3.752

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.