Literature DB >> 14671753

[Serum protein electrophoresis: comparison of capillary zone electrophoresis Capillarys (Sebia) and agarose gel electrophoresis Hydrasys (Sebia)].

B Lissoir1, P Wallemacq, D Maisin.   

Abstract

Since several years, serum proteins electrophoresis became a routine analysis, mainly performed by agarose gel electrophoresis, frequently semi-automated. We compared the new fully automated capillary electrophoresis system from Sebia, Capillarys, with our reference method, agarose gel electrophoresis Hydrasys (Sebia). This study focused on the evaluation of both the analytical performances and some practical aspects such as ease of use, rapidity, costs. It appears clearly from that study that both methods give similar results for the detection of monoclonal proteins. We notice that the capillary electrophoresis (Capillarys) displays higher sensitivity (97.2%) than the agarose gel electrophoresis Hydrasys (93.5%), however with a lower specificity (93.7 versus 98.9%). On the other hand, the Capillarys method displays obvious practical advantages such as full automation, ease of use and rapidity.

Entities:  

Mesh:

Year:  2003        PMID: 14671753

Source DB:  PubMed          Journal:  Ann Biol Clin (Paris)        ISSN: 0003-3898            Impact factor:   0.459


  4 in total

1.  High false-positive rate for monoclonal gammopathy using capillary electrophoresis (CAPILLARYS 2) alone.

Authors:  Richard Sheng Poe Huang; Deanna Alicia Oleske; Ashok Tholpady; Brian N Chang; Amitava Dasgupta; Andy Nguyen; Amer Wahed
Journal:  J Clin Lab Anal       Date:  2013-12-27       Impact factor: 2.352

2.  Inability to Measure M-Protein With Capillary Zone Electrophoresis (CAPPILLARYS 2) in Tracings With NonDiscernable Peaks.

Authors:  Richard S P Huang; Amitava Dasgupta; Andy N D Nguyen; Amer Wahed
Journal:  J Clin Lab Anal       Date:  2014-08-17       Impact factor: 2.352

3.  Association of BAFF -871C/T Promoter Polymorphism with Hepatitis C-Related Mixed Cryoglobulinemia in a Cohort of Egyptian Patients.

Authors:  Mona Wagdy Ayad; Amany A Elbanna; Dalia A Elneily; Amany S Sakr
Journal:  Mol Diagn Ther       Date:  2015-04       Impact factor: 4.074

4.  Establishment of Reference Intervals for Serum Protein Electrophoresis of Apparently Healthy Adults in Addis Ababa, Ethiopia.

Authors:  Demiraw Bikila; Tadesse Lejisa; Yosef Tolcha; Chala Bashea; Mehari Meles; Tigist Getahun; Genet Ashebir; Wossene Habtu; Feyissa Challa; Ousman Mohammed; Melkitu Kassaw; Adisu Kebede; Letebrhan G/Egzeabher; Endalkachew Befekadu; Mistire Wolde; Aster Tsegaye
Journal:  Int J Gen Med       Date:  2022-08-23
  4 in total