Evaluation of surface topography changes in three NiTi file systems using rotary and reciprocal motion: An atomic force microscopy study.

Yalpi Fatma1, Uzun Ozgur.   

Abstract

AIM: To evaluate the surface topography changes in three nickel-titanium (NiTi) file systems using either rotary or reciprocal motion using atomic force microscopy (AFM), and to determine the effect of scanning area on the AFM results in this study.
METHODOLOGY: Five points on a F2 Protaper file, R25 Reciproc file, and a Primary file from WaveOne systems were scanned preoperatively in 1 × 1 and 5 × 5 µm(2) with an AFM device that can scan an intact (not sectioned) file. One standardized resin block was used for each instrument, according to the manufacturer's recommendations. Points were re-scanned postoperatively using the same AFM and settings. Root-mean-square (RMS) and roughness average (Ra) values were obtained. The preoperative and postoperative surface topographies were compared separately in terms of RMS and Ra values. The surface topography change scores were analyzed using Kruskal-Wallis and Mann-Whitney U tests using a 0.10 significance level.
RESULTS: There were no significant differences preoperatively among the NiTi file systems in 1 × 1 or 5 × 5 µm(2) areas. Postoperatively, the WaveOne Primary had more surface irregularities (significant for 5 × 5 µm(2) scan in Ra evaluation).
CONCLUSIONS: Three-dimensional AFM images of instrument surfaces showed topographic irregularities preoperatively and postoperatively. AFM results differ depending on the scanning area and file used.
Copyright © 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  atomic force microscope; endodontics; reciprocal motion; rotary motion

Mesh:

Substances:

Year:  2013        PMID: 24375725     DOI: 10.1002/jemt.22325

Source DB:  PubMed          Journal:  Microsc Res Tech        ISSN: 1059-910X            Impact factor:   2.769


  5 in total

1.  Effect of multiple autoclave cycles on the surface roughness of HyFlex CM and HyFlex EDM files: an atomic force microscopy study.

Authors:  K Yılmaz; G Uslu; T Özyürek
Journal:  Clin Oral Investig       Date:  2018-02-13       Impact factor: 3.573

2.  Qualitative Assessment of the Surface Topographic Changes of XP-endo Shaper and TruNatomy files after exposure to Sodium Hypochlorite and Ethylenediaminetetraacetic Acid.

Authors:  Jerry Jose; Akshay Khandelwal; Riluwan Siddique
Journal:  Eur Endod J       Date:  2021-08

3.  The effect of root canal preparation on the surface roughness of WaveOne and WaveOne Gold files: atomic force microscopy study.

Authors:  Taha Özyürek; Koray Yılmaz; Gülşah Uslu; Gianluca Plotino
Journal:  Restor Dent Endod       Date:  2018-02-02

4.  A new method for assessment of nickel-titanium endodontic instrument surface roughness using field emission scanning electronic microscope.

Authors:  Khoa Van Pham; Canh Quang Vo
Journal:  BMC Oral Health       Date:  2020-08-31       Impact factor: 2.757

Review 5.  Metallurgical Tests in Endodontics: A Narrative Review.

Authors:  Alessio Zanza; Marco Seracchiani; Rodolfo Reda; Gabriele Miccoli; Luca Testarelli; Dario Di Nardo
Journal:  Bioengineering (Basel)       Date:  2022-01-12
  5 in total