Literature DB >> 24373656

Oral epithelial cell reaction after exposure to Invisalign plastic material.

Thyagaseely Premaraj1, Samantha Simet2, Mark Beatty3, Sundaralingam Premaraj4.   

Abstract

INTRODUCTION: Invisalign plastic aligners (Align Technology, Santa Clara, Calif) are used to correct malocclusions. The aligners wrap around the teeth and are in contact with gingival epithelium during treatment. The purpose of this study was to evaluate the cellular responses of oral epithelium exposed to Invisalign plastic in vitro.
METHODS: Oral epithelial cells were exposed to eluate obtained by soaking Invisalign plastic in either saline solution or artificial saliva for 2, 4, and 8 weeks. Cells grown in media containing saline solution or saliva served as controls. Morphologic changes were assessed by light microscopy. The 3-[4, 5-dimethythiazol- 2-yl]-2, 5-diphenyl tetrazolium bromide assay and flow cytometry were used to determine cell viability and membrane integrity, respectively. Cellular adhesion and micromotion of epithelial cells were measured in real time by electrical cell-substrate impedance sensing.
RESULTS: Cells exposed to saline-solution eluate appeared rounded, were lifted from the culture plates, and demonstrated significantly increased metabolic inactivity or cell death (P <0.05). Saliva eluates did not induce significant changes in cell viability compared with untreated cells. Flow cytometry and electric cell-substrate impedance sensing showed that cells treated with saline-solution eluate exhibited compromised membrane integrity, and reduced cell-to-cell contact and mobility when compared with saliva-eluate treatment.
CONCLUSIONS: Exposure to Invisalign plastic caused changes in viability, membrane permeability, and adhesion of epithelial cells in a saline-solution environment. Microleakage and hapten formation secondary to compromised epithelial integrity might lead to isocyanate allergy, which could be systemic or localized to gingiva. However, these results suggest that saliva might offer protection.
Copyright © 2014 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24373656     DOI: 10.1016/j.ajodo.2013.09.011

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  4 in total

1.  In vitro cytotoxicity of different thermoplastic materials for clear aligners.

Authors:  Stefano Martina; Roberto Rongo; Rosaria Bucci; Armando Viviano Razionale; Rosa Valletta; Vincenzo D'Antò
Journal:  Angle Orthod       Date:  2019-04-04       Impact factor: 2.079

2.  Patient survey on Invisalign® treatment comparing [corrected] the SmartTrack® material to the previously used [corrected] aligner material.

Authors:  Anne-Kathrin Bräscher; Dietmar Zuran; Robert E Feldmann; Justus Benrath
Journal:  J Orofac Orthop       Date:  2016-10-24       Impact factor: 1.938

3.  Cytotoxicity assessment of different clear aligner systems: An in vitro study.

Authors:  Aseel Alhendi; Rita Khounganian; Abdulazez Almudhi
Journal:  Angle Orthod       Date:  2022-06-07       Impact factor: 2.684

4.  Colour stabilities of three types of orthodontic clear aligners exposed to staining agents.

Authors:  Chen-Lu Liu; Wen-Tian Sun; Wen Liao; Wen-Xin Lu; Qi-Wen Li; Yunho Jeong; Jun Liu; Zhi-He Zhao
Journal:  Int J Oral Sci       Date:  2016-12-16       Impact factor: 6.344

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.