Literature DB >> 24373022

Stability of paramedian inserted palatal mini-implants at the initial healing period: a controlled clinical study.

Manuel Nienkemper1, Alexander Pauls2, Björn Ludwig3, Dieter Drescher1.   

Abstract

OBJECTIVES: To assess the stability development of paramedian in comparison with midpalatal inserted mini-implants.
MATERIAL AND METHODS: The test group consisted of 21 consecutively treated patients (13.7 ± 4.6 years). In each patient, a mini-implant was inserted paramedian in the anterior palate. Measurement of the insertion depth (ID), the maximum insertion torque (IT), and resonance frequency analysis (RFA) was performed at T0. RFA was repeated after 2 weeks (T1), 4 weeks (T2), and 6 weeks (T3). Correlations between measuring methods were calculated. RFA values at different times were tested for statistical differences. Data were compared with a group of patients who received median mini-implants of the same size.
RESULTS: Initial stability was 14.06 ± 4.35 Ncm (IT) and 26.60 ± 5.28 ISQ (RFA) with an ID of 7.02 ± 1.04 mm. RFA and IT (r = 0.49, P = 0.023) showed a moderate significant correlation. Stability remained relatively constant, showing no significant differences between measurement times. Overall, RFA values decreased non-significantly by 2.25 ± 6.85 ISQ to a level of 24.35 ± 5.39 after 6 weeks. Comparing development of stability over time, it was found that significant differences were present at T0 and T1 (T0: -9.54 ISQ, P < 0.0001; T1: -3.69, P = 0.041).
CONCLUSIONS: Paramedian inserted mini-implants provided sufficient stability. Showing a lower primary stability, RFA values did not differ from the control group from week four on, as no significant decrease in stability occurred at the initial healing period.
© 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  healing; insertion site; mini-implants; palate; resonance frequency analysis; skeletal anchorage; stability

Mesh:

Substances:

Year:  2013        PMID: 24373022     DOI: 10.1111/clr.12321

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  5 in total

1.  Orthodontic mini-implant stability at different insertion depths : Sensitivity of three stability measurement methods.

Authors:  Manuel Nienkemper; Natascha Santel; Ralf Hönscheid; Dieter Drescher
Journal:  J Orofac Orthop       Date:  2016-06-07       Impact factor: 1.938

2.  Insertion torque values and success rates for paramedian insertion of orthodontic mini-implants : A retrospective study.

Authors:  Bruno Di Leonardo; Björn Ludwig; Jörg Alexander Lisson; Luca Contardo; Rossano Mura; Jan Hourfar
Journal:  J Orofac Orthop       Date:  2018-02-20       Impact factor: 1.938

3.  An interview with Benedict Wilmes.

Authors:  Guilherme Thiesen; Marcus Vinícius Neiva Nunes do Rego; Jorge Faber; Ki Beom Kim
Journal:  Dental Press J Orthod       Date:  2016 Nov-Dec

4.  Risk of root damage after using lateral cephalogram and intraoral scan for guided insertion of palatal miniscrews.

Authors:  Manuel Nienkemper; Björn Ludwig
Journal:  Head Face Med       Date:  2022-09-03       Impact factor: 2.246

5.  RFA measurements of survival midpalatal orthodontic mini-implants in comparison to initial healing period.

Authors:  Manuel Nienkemper; Jan H Willmann; Kathrin Becker; Dieter Drescher
Journal:  Prog Orthod       Date:  2020-02-17       Impact factor: 2.750

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.