Literature DB >> 24372424

Pulse pressure variation does not reflect stroke volume variation in mechanically ventilated rats with lipopolysaccharide-induced pneumonia.

Thomas G V Cherpanath1, Lonneke Smeding, Wim K Lagrand, Alexander Hirsch, Marcus J Schultz, Johan A B Groeneveld.   

Abstract

1. The present study examined the relationship between centrally measured stroke volume variation (SVV) and peripherally derived pulse pressure variation (PPV) in the setting of increased total arterial compliance (CA rt ). 2. Ten male Wistar rats were anaesthetized, paralysed and mechanically ventilated before being randomized to receive intrapulmonary lipopolysaccharide (LPS) or no LPS. Pulse pressure (PP) was derived from the left carotid artery, whereas stroke volume (SV) was measured directly in the left ventricle. Values of SVV and PPV were calculated over three breaths. Balloon inflation of a catheter positioned in the inferior vena cava was used, for a maximum of 30 s, to decrease preload while the SVV and PPV measurements were repeated. Values of CA rt were calculated as SV/PP. 3. Intrapulmonary LPS increased CA rt and SV. Values of SVV and PPV increased in both LPS-treated and untreated rats during balloon inflation. There was a correlation between SVV and PPV in untreated rats before (r = 0.55; P = 0.005) and during (r = 0.69; P < 0.001) occlusion of the vena cava. There was no such correlation in LPS-treated rats either before (r = -0.08; P = 0.70) or during (r = 0.36; P = 0.08) vena cava occlusion. 4. In conclusion, under normovolaemic and hypovolaemic conditions, PPV does not reflect SVV during an increase in CA rt following LPS-induced pneumonia in mechanically ventilated rats. Our data caution against their interchangeability in human sepsis.
© 2013 Wiley Publishing Asia Pty Ltd.

Entities:  

Keywords:  arterial compliance; haemodynamic parameters; hypovolaemia; lipopolysaccharide; mechanical ventilation; pulse pressure; sepsis; stroke volume

Mesh:

Substances:

Year:  2014        PMID: 24372424     DOI: 10.1111/1440-1681.12187

Source DB:  PubMed          Journal:  Clin Exp Pharmacol Physiol        ISSN: 0305-1870            Impact factor:   2.557


  3 in total

Review 1.  Functional haemodynamic monitoring.

Authors:  Michael R Pinsky
Journal:  Curr Opin Crit Care       Date:  2014-06       Impact factor: 3.687

2.  Dynamic Arterial Elastance as a Ventriculo-Arterial Coupling Index: An Experimental Animal Study.

Authors:  Manuel Ignacio Monge García; Zhongping Jian; Feras Hatib; Jos J Settels; Maurizio Cecconi; Michael R Pinsky
Journal:  Front Physiol       Date:  2020-04-06       Impact factor: 4.566

3.  Comparison of Changes in PPV Using a Tidal Volume Challenge with a Passive Leg Raising Test to Predict Fluid Responsiveness in Patients Ventilated Using Low Tidal Volume.

Authors:  Ahmed I Elsayed; Khaled Aw Selim; Hanan E Zaghla; Hossam E Mowafy; Mohammed A Fakher
Journal:  Indian J Crit Care Med       Date:  2021-06
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.