In vivo tomographic imaging with fluorescence and MRI using tumor-targeted dual-labeled nanoparticles.

Yue Zhang1, Bin Zhang1, Fei Liu2, Jianwen Luo3, Jing Bai1.   

Abstract

Dual-modality imaging combines the complementary advantages of different modalities, and offers the prospect of improved preclinical research. The combination of fluorescence imaging and magnetic resonance imaging (MRI) provides cross-validated information and direct comparison between these modalities. Here, we report on the application of a novel tumor-targeted, dual-labeled nanoparticle (NP), utilizing iron oxide as the MRI contrast agent and near infrared (NIR) dye Cy5.5 as the fluorescent agent. Results of in vitro experiments verified the specificity of the NP to tumor cells. In vivo tumor targeting and uptake of the NPs in a mouse model were visualized by fluorescence and MR imaging collected at different time points. Quantitative analysis was carried out to evaluate the efficacy of MRI contrast enhancement. Furthermore, tomographic images were also acquired using both imaging modalities and cross-validated information of tumor location and size between these two modalities was revealed. The results demonstrate that the use of dual-labeled NPs can facilitate the dual-modal detection of tumors, information cross-validation, and direct comparison by combing fluorescence molecular tomography (FMT) and MRI.

Entities:  

Keywords:  dual-modality; fluorescence molecular tomography (FMT); magnetic resonance imaging (MRI); nanoparticle

Mesh:

Substances:

Year:  2013        PMID: 24368885      PMCID: PMC3869830          DOI: 10.2147/IJN.S52492

Source DB:  PubMed          Journal:  Int J Nanomedicine        ISSN: 1176-9114


Introduction

Dual-modality imaging is a powerful method that combines the complementary advantages of different imaging modalities.1 The fusion of functional/molecular and anatomical modalities, including positron emission tomography/computed tomography (PET/CT), single-photon emission CT (SPECT)/CT, PET/magnetic resonance imaging (MRI), etc, has gained worldwide attention as providing more reliable and accurate disease detection.2 As a non-radiative functional imaging modality, fluorescence imaging is emerging as an important method and plays a significant role in tumor detection3 and drug development.4 Fluorescence imaging has several advantages over other modalities, such as high sensitivity and specificity, operational simplicity, safety and cost effectiveness.5 Lately, combined with the development of versatile fluorescent probes, especially the near-infrared fluorescent (NIRF) probes, fluorescence molecular tomography (FMT) is becoming a promising tool to noninvasively resolve three-dimensional (3D) spatial distribution of fluorescence probes associated with molecular and cellular functions.6 On the other hand, MRI provides high spatial resolution with outstanding contrast features in soft tissues,7 3D anatomic details throughout the body, and has been widely used in clinical oncology imaging.8 Novel contrast agents that modulate T1 and T2 relaxation have also rendered MRI a tool for visualizing cellular and subcellular events.9 In light of these recent advances, the combination of fluorescence imaging and MRI is particularly attractive, and has been utilized for tumor detection,8 imaging of myocardium,10 protein expression,11 etc. Recently, nanoparticle (NP)-based imaging has attracted considerable attention. NPs have been widely used as the imaging contrast agent for their potential for earlier diagnosis,12 greater biocompatibility, and reduced toxicity.13 To achieve enhanced specificity and sensitivity, tumor-targeted NPs have been developed, and their feasibility in tumor-targeted imaging has been demonstrated in vivo.8,14 Using monoclonal antibodies targeted against the receptor, epidermal growth factor receptor (EGFR) is under intense investigation, both as a prognostic marker and for therapy by means of optical imaging15 and MRI.16 The EGFR signaling pathway plays an important role in the regulation of cell proliferation, etc.17 EGFR is overexpressed in many solid tumors, including cancers of breast, brain, colon, etc,18 and the different levels of expression between normal cells and tumor cells make EGFR a potential marker for in vivo receptor-targeted molecular imaging.15 Furthermore, dual-labeled NPs have made a significant contribution to promoting the development of dual-modality imaging. By integrating several imaging agents with different properties, dual-labeled NPs can be used to evaluate the same molecular target with multiple imaging modalities,19 quantitatively assess tumor-targeting efficacy,20 and detect tumors at early stages with high accuracy.21 In order to facilitate the cross-validation and direct comparison between the tomographic images acquired by FMT and MRI, an EGFR-targeted, dual-labeled magnetic-fluorescent NP was synthesized. Fluorescence imaging and MRI were used to observe the dual-labeled NP distribution in a mouse mammary tumor model in vivo. A series of fluorescence images and MRI images were collected at different time points to observe tumor targeting and uptake of the NPs, and quantitative analysis was carried out. Tomographic images acquired from fluorescence imaging and MRI were also shown. The results from both imaging modalities showed high correspondence with each other. Finally, histological analysis was conducted to further confirm the imaging results.

Materials and methods

Materials

Iron(III) acetylacetonate (Fe(acac)3), oleylamine, 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC), N-hydroxysulfosuccinimide sodium salt (sulfo-NHS), fetal bovine serum, Penicillin-Streptomycin were purchased from Sigma-Aldrich (St Louis, MO, USA). Diphenyl ether was purchased from Sinopharm Chemical Reagent Beijing, Co, Ltd (Beijing, People’s Republic of China). The anti-EGFR monoclonal antibody (mAb) was purchased from Boehringer Ingelheim Pharma GmbH and Co. KG. (Ingelheim, Gemany), and Cy5.5-NHS ester was purchased from GE Healthcare Life Science (Buckinghamshire, UK).

Preparation of tumor-targeted dual-labeled NP

To achieve optimal dual-modality imaging contrast, paramagnetic iron oxide (IO) NPs conjugated with NIRF dye-labeled mAbs were synthesized. IO NPs were prepared as previously described.22–24 Typically, 2.1 g of Fe(acac)3, 7.9 mL of oleylamine, and 24 g of HOOC-PEG-COOH (12 mmol, Mn =2,000) were dissolved in 100 mL of diphenyl ether solution. After being purged with nitrogen, the reaction mixture was quickly heated and kept refluxing for 0.5 hours. After the reaction mixture was cooled to room temperature, ether was used to precipitate the resultant Fe3O4 nanocrystals out of it. The precipitate was then re-dissolved in ethanol followed by addition of ether as precipitant. This purifying procedure was repeated for three cycles. The polyethylene glycol (PEG)-coated Fe3O4 nanocrystals finally obtained were dissolved in phosphate-buffered saline (PBS; Sigma, St Louis, MO, USA). Anti-EGFR mAbs were selected as the ligand for EGFR to achieve targeted delivery of the NP to the mammary tumor. The anti-EGFR mAb was dialyzed against 1 L of 0.15 M sodium chloride for 4 hours at room temperature, and was dialyzed again overnight using a fresh liter of 0.15 M sodium chloride at 4°C. A 10 mg/mL solution of Cy5.5-NHS ester in dimethyl sulfoxide (DMSO) was then added gradually to the antibody solution while stirring in the dark. To separate the free dye, the mixture was dialyzed against 1 L of 0.15 M sodium chloride for 4 hours at room temperature. This dialysis was repeated using a fresh liter of 0.15 M sodium chloride overnight at 4°C. Finally, the labeled antibody solution was filtered through a 0.22 μm syringe filter. Cy5.5 dye-labeled anti-EGFR mAbs were conjugated to the surface of IO NPs via the classical EDC/sulfo-NHS method.23,24 Typically, EDC (2.50 μmol) and sulfo-NHS (6.25 μmol) were dissolved in 950 μL of a 0.01 M PBS solution containing 2.0 mg of Fe3O4 nanocrystals. After approximately 15 minutes, 50 μL of a 0.01 M PBS solution containing 1 mg of Cy5.5 labeled anti-EGFR antibody was introduced. The reaction was run overnight at 4°C. The resultant conjugates were collected at 13,000 rpm to remove the impurities and unreacted Cy5.5 labeled anti-EGFR antibody molecules and then re-dissolved in PBS (1 mL) and kept at 4°C. Transmission electron microscopy (TEM) of IO-anti-EGFR-Cy5.5 was used to estimate the diameter of the particle. In order to determine the concentration of iron in the probe, O-phenanthroline spectrophotometry was carried out. Firstly, the standard solution of iron was prepared and then diluted to different known concentrations. Then a 0.10% solution of O-phenanthroline and a 10% solution of hydroxylamine hydrochloride were added to the standard solutions of serial concentration. The standard curve was created by measuring the percent transmittance of the mixed solutions by using the spectrophotometer (Cary 50 UV−vis, Angilent Technologies, CA, USA). Third, the probe solution was processed as above, and the percent transmittance was also measured. Thus, the concentration of the probe could be determined according to the standard curve. The optical properties of anti-EGFR-Cy5.5 and IO-anti-EGFR-Cy5.5 were also investigated.

Cell lines

Human breast adenocarcinoma cell lines MDA-MB-231 (EGFR-positive) and MDA-MB-453 (EGFR-negative) were purchased from National Platform of Experimental Cell Resources for Sci-Tech (Beijing, People’s Republic of China), and were maintained at 37°C in a humidified atmosphere containing 5% CO2 in RPMI 1640, supplemented with 10% fetal bovine serum and 1% Penicillin- Streptomycin.

In vitro binding studies

Both cell lines cultured in a 35 mm confocal dish (Corning, New York City, NY, USA) were incubated with IO-anti-EGFR-Cy5.5 of the same concentration (containing 135 mg Fe) at 37°C for 1 hour. After washing with PBS three times, cells were fixed with 4% paraformaldehyde (Beijing Chemical Works, Beijing, People’s Republic of China) and cell nuclei were then stained with Hoechst 33342 (Sigma-Aldrich, St Louis, MO, USA) by incubating the cells with 10 mg/mL Hoechst 33342 solution for 15 minutes at 37°C. Cells were then washed again three times, and the dishes were mounted for microscopic examination using a confocal microscope (A1R MP, Nikon, Tokyo, Japan).

Mouse mammary tumor model

Animal experiments were approved by the Institutional Animal Care and Use Committee of Tsinghua University, Beijing. 5 × 106 MDA-MB-231 cells in 0.15 mL PBS were injected subcutaneously into the upper right mammary fat pad of five 5-week-old female BALB/c-nude mice. When the average diameter of tumors reached ~6 mm, the mice were imaged.

In vivo fluorescent imaging

All fluorescence imaging experiments were performed on a home-made fluorescence imaging system. A 300 W Xenon lamp (Asahi Spectra, Torrance, CA, USA) was employed as the excitation source. Both reflectance imaging and tomographic imaging were carried out in the experiments. A collimation lens was used in reflectance imaging to generate approximately uniform epi-illumination; in the tomographic imaging, a fiber was attached to the lamp to generate a light spot focused onto the surface of the mouse. A 512 × 512 pixel, electron-multiplying CCD (EMCCD) camera (iXon DU-897, Andor, Belfast, Northern Ireland, UK) was cooled to −70°C and used to detect the fluorescence signals. A 35 mm f/1.6 lens (C3514-M, Pentax, Tokyo, Japan) was coupled to the EMCCD camera. The EMCCD camera and the excitation light source were vertically rotated, while the mouse was horizontally fixed on an animal holder (Figure 1A and B). The same mouse positions were carefully maintained, and identical imaging parameters were used, throughout the experiments. Fluorescent images were acquired with a 670±5 excitation filter and a Cy5.5 emission filter (695–770 nm, Caliper Life Sciences, Hopkinton, MA, USA). The mice were anesthetized with an isoflurane-oxygen gas mixture during the imaging process.
Figure 1

The animal holder.

Notes: (A) Components of the holder: a plastic tube and two carbon sticks to hold the mouse. Fixation mode of the holder in the homemade fluorescence molecular tomography system (B) and in the customized rodent coil (C).

A total of 75 μL of IO-anti-EGFR-Cy5.5 NPs (1.14 nM Fe per kg of mouse body weight) was administered via the tail vein before imaging. Fluorescent reflectance images were collected for each mouse (n=5) at four different time points to monitor the changes in fluorescence intensity in the tumor over time; the exposure time of CCD was 4 seconds. Fluorescent images for FMT were collected 12 hours post-injection, utilizing 36 projections with an angular increment of 10°. The total scan time for FMT was about 10 minutes. In fluorescence reconstruction, only the tumor region was reconstructed; the resulting reconstruction had the dimensions 31 × 31 × 18 with a pixel size of 1 × 1 × 1 mm3. The surface of the mouse was first extracted from the white light images by an optimal radon transform.25 A 3D solid model was constructed using this information, and then discretized into finite elements in order to calculate the light transportation using the finite elements method (FEM).26,27 The weight matrix was subsequently established by mapping the excitation light and the fluorescent images of each angle into the corresponding position of the finite element meshes. Finally, the algebraic reconstruction technique (ART) method was adopted to reconstruct the 3D dual-labeled NP distribution.

In vivo MRI

MRI experiments were performed on a 3T MRI scanner (Achieva 3.0T TX; Philips Healthcare, Best, The Netherlands) using a customized rodent coil (Figure 1C). During the experiments, mice were fixed on the same holder as in the fluorescent imaging process, and were anesthetized with intraperitoneal injection of avertin (350 mg/kg). MR images of each mouse (n=5) were collected before and 12 hours after the NP injection. The imaging sequences included T1-weighted turbo field echo method with a repetition time (TR) of 7.8 ms, an echo time (TE) of 3.3 ms, T2-weighted turbo spin echo method with a TR of 2,900 ms, and a TE of 214.1 ms. Multi-echo spin echo with six different TE values ranging from 15 ms to 90 ms were also used to obtain T2 maps of the whole mouse. Multi-echo T2 images of slices were used for calculating T2 maps using a commercial software (Volume View, Philips Healthcare, Best, The Netherlands). To estimate the contrast enhancement of NPs in the tumor at different time points, MRI signal changes were measured before and 12 hours after the injection. Using the MRI signal level of muscle tissue as a baseline, relative signal intensity was determined as follows:

Statistical analysis

Quantitative data were expressed as mean ± standard deviation (SD). The paired Student’s t-test was used to compare data in the regions of interest (ROIs) drawn around the tumor on the T2-weighted images and T2 maps from the same animal before and after injection to evaluate the efficacy of contrast enhancement. P<0.05 was considered statistically significant.

Histological analysis

After the mice were sacrificed, tumor tissues were collected and embedded optimal cutting temperature compound (OCT) (Sakura Fine-tek, Torrance, CA, USA), and 10 μm-thick sections were cut. Frozen tissue sections were incubated with Prussian blue staining solution to confirm the presence of IO NPs in the tissue sections. The slides were examined under bright field microscopy (Eclipse 90i, Nikon, Tokyo, Japan) after counterstaining with eosin (Leagene Biotech, Beijing, People’s Republic of China).

Results

Characterization of IO-anti-EGFR-Cy5.5

The components of IO-anti-EGFR-Cy5.5 are schematically depicted in Figure 2A. The NP consists of an IO core coated with PEG and Cy5.5-labeled mAbs (Figure 2A). According to the TEM images of the NPs (Figure 2A), Fe3O4 magnetic NPs were approximately spherical, and the mean size was approximately 14 nm. The concentration of Fe in the probe was 1.7 mg/mL, determined by O-phenanthroline spectrophotometry.
Figure 2

Characteristics of the IO-anti-EGFR-Cy5.5 nanoparticle.

Notes: (A) Schematic representation of the nanoparticle and the TEM image of IO-anti-EGFR-Cy5.5. (B) Normalized emission spectrum of IO-anti-EGFR-Cy5.5. (C and D) Normalized absorbance and emission spectra of anti-EGFR-Cy5.5.

Abbreviations: EGFR, epidermal growth factor receptor; IO, iron oxide; PEG, polyethylene glycol; TEM, transmission electron microscopy.

The fluorescence emission spectrum of IO-anti-EGFR-Cy5.5 is shown in Figure 2B, while the fluorescence absorbance spectrum and emission spectrum of anti-EGFR-Cy5.5 are shown in Figure 2C and D, respectively. As shown in fluorescence spectra of anti-EGFR-Cy5.5, its absorbance peak is 670 nm, and its emission peak is ~700 nm; filters of the corresponding wavelength are used in the following in vivo fluorescence imaging. Furthermore, according to the product protocol of Cy5.5-NHS, the ratio of antibody to Cy5.5 is 1:2, calculated as follows: where A650 and A280 represent the absorbance of the Cy5.5-labeled anti-EGFR at the corresponding wavelengths (ie, 650 nm and 280 nm). The ratio of antibody to IO particle is 4:1. Thus, eight Cy5.5 molecules are labeled to each IO NP.

Specificity of IO-anti-EGFR-Cy5.5 to cancer cells

In vitro binding studies were carried out to evaluate the specificity of the dual-labeled NP to EGFR-expressing tumor cells. MDA-MB-231 and MDA-MB-453 cells were incubated with IO-anti-EGFR-Cy5.5 under identical circumstances. Fluorescence images of MDA-MB-231 cells (Figure 3A) indicated that a strong fluorescence signal (red) was detected in the cells. In contrast, a negligible signal was detected in MDA-MB-453 cells (Figure 3B). The cell nuclei were counterstained with Hoechst 33342 (blue).
Figure 3

Specific binding of IO-anti-EGFR-Cy5.5 to targeted tumor cells line.

Notes: Strong fluorescence signals (Red) were found on the cell surface of MDA-MB-231 which overexpress EGFR, while there are no evident fluorescence signals on the cell surface of MDA-MB-453. Blue: Hoechst 33342 counterstaining.

Abbreviations: EGFR, epidermal growth factor receptor; IO, iron oxide.

In vivo fluorescence reflectance imaging

Representative fluorescence reflectance imaging results from one mouse are shown in Figure 4; the accumulation of the NPs in the tumor area is detected, as evidenced by the changes in the fluorescent signals in serial NIR fluorescence images at four different time points. Meanwhile, strong fluorescent signals were also detected in the abdominal cavity, which was caused by the uptake of the NP by the liver and spleen.15
Figure 4

Reflectance fluorescence images at four time points after the nanoparticle injection. Pixel values are reported as CCD counts, which is in proportion to fluorescence intensity.

Note: Red arrows indicate the tumor.

In vivo FMT and MRI

To achieve the 3D distribution of the dual-labeled NP, in vivo tomographic imaging of the mammary xenograft mouse model was performed using both FMT and MRI. As shown in Figure 5A and B, the tumor can be visualized with high contrast in both axial and coronal slices. Meanwhile, reductions of T2 signal and values in T2-weighted images were observed in the area of the tumor 12 hours after the NP injection (Figure 5E–G), which suggests NP accumulation in tumors. Furthermore, signal changes in the tumor region are non-uniform, indicating the heterogeneous intratumoral distribution of the NPs. Using the MRI signal level of muscle tissue as a baseline, paired t-tests demonstrated that there was a significant change in relative magnetic signal intensity (P<0.05) 12 hours after the NP injection (Figure 6A). Similar results were obtained in the paired t-test for T2 values (Figure 6B), which further demonstrated the accumulation of the NP in the tumor. Tumor uptake of IO-anti-EGFR-Cy5.5 was confirmed by histology using Prussian blue staining. Cells with blue staining were found in tumor tissue sections (Figure 6C). At the same time, uptake of the NP in the liver was also significant, as evidenced by a conspicuous signal decrease detected in the liver (Figure 5D and H) and in liver tissue slices (Figure 6D).
Figure 5

In vivo MRI of MDA-MB-231 mammary tumor using IO-anti-EGFR-Cy5.5.

Notes: (A, B, E, and F) Representative axial and coronal slices through the tumor before and 12 hours after the injection of the nanoparticle. Tumors (indicated by red circles) were visualized with high contrast. (C and G) T2 maps before and after the injection of the nanoparticle. (D and H) Axial slices through the liver showing significant T2 signal changes in the liver.

Abbreviations: EGFR, epidermal growth factor receptor; IO, iron oxide; MRI, magnetic resonance imaging.

Figure 6

Tracking changes of T2 intensity and T2 values before and after the nanoparticle injection.

Notes: Changes of the T2 intensity (A) and T2 value (B) of tumors before and after the nanoparticle injection. Columns, mean; error bars, standard deviation. *indicates P<0.05. Results of Prussian blue staining of the iron oxide nanoparticles in tumor (C) and liver tissues (D).

Furthermore, 3D FMT reconstruction reveals the distribution of the NPs in the tumor region 12 hours after the injection. Figure 7 shows the axial MR images and the corresponding FMT images of the same mouse. As shown, NP distribution revealed in the fluorescence tomographic images corresponds well with that revealed in the MR images.
Figure 7

Tomographic images by FMT and MRI.

Notes: (A) and (D) position of the cross section (red line). (B, C, E and F) MRI and fluorescence tomographic images of the selected slice. Fluorescence reconstructed values of each image were normalized to the respective maximum value. The unit of fluorescence reconstructed values is arbitrary unit.

Abbreviations: au, arbitrary unit; FMT, fluorescence molecular tomography; MRI, magnetic resonance imaging.

Discussion

Fluorescence imaging, especially FMT, enables noninvasive detection and 3D reconstruction of specific molecular events, while MRI allows for imaging with high spatial resolution (0.5 mm herein) anatomic information. In this work, we acquired tomographic images of MRI and fluorescence imaging, which visualized the distribution of NIR dye-labeled, tumor-targeted NPs in vivo, and signal contrasts were detected and analyzed. As shown in the results, the new application, combining our homemade FMT system and the well-established MRI system, can provide cross-validated information and direct comparison between both modalities. The comparison and cross-validation may be further used for probe design28 and quantification.29 However, fluorescence and MR images were collected sequentially and separately. Accurate fusion of the images from different imaging modalities will need non-frigid registration, which is intrinsically difficult. In contrast, simultaneous image scanning by both modalities will benefit from the inherent registration due to fixed instrument geometry.30 According to our previous investigation,31 the spatial resolution achieved by hybrid FMT-CT was at least 1.2 mm. In our future work, we are planning to simultaneously implement FMT and MR imaging on a hybrid FMT-MRI system, which enables high accuracy FMT reconstruction21 and offers high soft-tissue contrast, high resolution, and high sensitivity.30 In comparison with other dual-labeled NPs, IO-anti-EGFR-Cy5.5 NPs show excellent biocompatibility, satisfying colloidal stability, and enhanced MR contrast.24 Furthermore, Cy5.5, as one representative NIRF dye, possesses the minimum absorbance spectra in the NIR region,32 and enables characterization of deep diseased tissues.18 Dual-modality magnetic-fluorescent NP, which imparts contrast in both imaging modalities, such as the one described herein, can extend the prospects of MRI-fluorescence imaging, and facilitate information cross-validation and direct comparison between different modalities. In addition, the toxicity of magnetic NPs is under intense investigation.33 According to our short-term (4.5 day) observation during the experiment, no side effects were observed on the mice after the probe injection. We will work on toxicity testing of the IO-anti-EGFR-Cy5.5 NP in the near future.

Conclusion

We synthesized a dual-labeled NP (IO-anti-EGFR-Cy5.5), which facilitates the tomographic visualization of tumor targeting on the macroscopic level with MRI and FMT. Information cross-validation and direct comparison between different modalities were achieved. Dual-modality imaging, combining fluorescence imaging and MRI, may have great potential in accurate 3D visualization of tumor targeting and other molecular processes in vivo.
  29 in total

1.  In vivo near-infrared fluorescence imaging of integrin alphavbeta3 in brain tumor xenografts.

Authors:  Xiaoyuan Chen; Peter S Conti; Rex A Moats
Journal:  Cancer Res       Date:  2004-11-01       Impact factor: 12.701

2.  Nanoparticle imaging of integrins on tumor cells.

Authors:  Xavier Montet; Karin Montet-Abou; Fred Reynolds; Ralph Weissleder; Lee Josephson
Journal:  Neoplasia       Date:  2006-03       Impact factor: 5.715

3.  Fluorescence tomography and magnetic resonance imaging of myocardial macrophage infiltration in infarcted myocardium in vivo.

Authors:  David E Sosnovik; Matthias Nahrendorf; Nikolaos Deliolanis; Mikhail Novikov; Elena Aikawa; Lee Josephson; Anthony Rosenzweig; Ralph Weissleder; Vasilis Ntziachristos
Journal:  Circulation       Date:  2007-03-05       Impact factor: 29.690

4.  Free-space fluorescence molecular tomography utilizing 360 degrees geometry projections.

Authors:  Nikolaos Deliolanis; Tobias Lasser; Damon Hyde; Antoine Soubret; Jorge Ripoll; Vasilis Ntziachristos
Journal:  Opt Lett       Date:  2007-02-15       Impact factor: 3.776

5.  Molecular imaging of tumor angiogenesis using alphavbeta3-integrin targeted multimodal quantum dots.

Authors:  Willem J M Mulder; Karolien Castermans; Judy R van Beijnum; Mirjam G A Oude Egbrink; Patrick T K Chin; Zahi A Fayad; Clemens W G M Löwik; Eric L Kaijzel; Ivo Que; Gert Storm; Gustav J Strijkers; Arjan W Griffioen; Klaas Nicolay
Journal:  Angiogenesis       Date:  2008-12-09       Impact factor: 9.596

Review 6.  Pre-clinical PET/MR: technological advances and new perspectives in biomedical research.

Authors:  Hans F Wehrl; Martin S Judenhofer; Stefan Wiehr; Bernd J Pichler
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03       Impact factor: 9.236

7.  Superparamagnetic iron oxide: pharmacokinetics and toxicity.

Authors:  R Weissleder; D D Stark; B L Engelstad; B R Bacon; C C Compton; D L White; P Jacobs; J Lewis
Journal:  AJR Am J Roentgenol       Date:  1989-01       Impact factor: 3.959

8.  Peptide-labeled near-infrared quantum dots for imaging tumor vasculature in living subjects.

Authors:  Weibo Cai; Dong-Woon Shin; Kai Chen; Olivier Gheysens; Qizhen Cao; Shan X Wang; Sanjiv S Gambhir; Xiaoyuan Chen
Journal:  Nano Lett       Date:  2006-04       Impact factor: 11.189

9.  Dual functional molecular imaging probe targeting CD20 with PET and optical imaging.

Authors:  Pramila Paudyal; Bishnuhari Paudyal; Yasuhiko Iida; Noboru Oriuchi; Hirofumi Hanaoka; Hideyuki Tominaga; Tomohiro Ishikita; Hiroki Yoshioka; Tetsuya Higuchi; Keigo Endo
Journal:  Oncol Rep       Date:  2009-07       Impact factor: 3.906

10.  Dual-function probe for PET and near-infrared fluorescence imaging of tumor vasculature.

Authors:  Weibo Cai; Kai Chen; Zi-Bo Li; Sanjiv S Gambhir; Xiaoyuan Chen
Journal:  J Nucl Med       Date:  2007-10-17       Impact factor: 10.057

View more
  15 in total

1.  Anatomical image-guided fluorescence molecular tomography reconstruction using kernel method.

Authors:  Reheman Baikejiang; Yue Zhao; Brett Z Fite; Katherine W Ferrara; Changqing Li
Journal:  J Biomed Opt       Date:  2017-05-01       Impact factor: 3.170

2.  An all-in-one nanoparticle (AION) contrast agent for breast cancer screening with DEM-CT-MRI-NIRF imaging.

Authors:  Jessica C Hsu; Pratap C Naha; Kristen C Lau; Peter Chhour; Renee Hastings; Brianna F Moon; Joel M Stein; Walter R T Witschey; Elizabeth S McDonald; Andrew D A Maidment; David P Cormode
Journal:  Nanoscale       Date:  2018-09-20       Impact factor: 7.790

3.  Self-prior strategy for organ reconstruction in fluorescence molecular tomography.

Authors:  Yuan Zhou; Maomao Chen; Han Su; Jianwen Luo
Journal:  Biomed Opt Express       Date:  2017-09-25       Impact factor: 3.732

4.  Differentiation of tumor vasculature heterogeneity levels in small animals based on total hemoglobin concentration using magnetic resonance-guided diffuse optical tomography in vivo.

Authors:  Tiffany C Kwong; Mitchell Hsing; Yuting Lin; David Thayer; Mehmet Burcin Unlu; Min-Ying Su; Gultekin Gulsen
Journal:  Appl Opt       Date:  2016-07-20       Impact factor: 1.980

5.  Gliomas: Motexafin Gadolinium-enhanced Molecular MR Imaging and Optical Imaging for Potential Intraoperative Delineation of Tumor Margins.

Authors:  Longhua Qiu; Feng Zhang; Yaoping Shi; Zhibin Bai; Jianfeng Wang; Yonggang Li; Donghoon Lee; Christopher Ingraham; Xiaoyuan Feng; Xiaoming Yang
Journal:  Radiology       Date:  2015-11-24       Impact factor: 11.105

6.  Spatiotemporally photoradiation-controlled intratumoral depot for combination of brachytherapy and photodynamic therapy for solid tumor.

Authors:  Ratul Mukerji; Jeffrey Schaal; Xinghai Li; Jayanta Bhattacharyya; Daisuke Asai; Michael R Zalutsky; Ashutosh Chilkoti; Wenge Liu
Journal:  Biomaterials       Date:  2015-12-02       Impact factor: 12.479

7.  Nanotoxic profiling of novel iron oxide nanoparticles functionalized with perchloric acid and SiPEG as a radiographic contrast medium.

Authors:  Muhamad Idham Mohamed; Mohd Khairul Amran Mohammad; Hairil Rashmizal Abdul Razak; Khairunisak Abdul Razak; Wan Mazlina Md Saad
Journal:  Biomed Res Int       Date:  2015-05-17       Impact factor: 3.411

8.  Iodinated oil-loaded, fluorescent mesoporous silica-coated iron oxide nanoparticles for magnetic resonance imaging/computed tomography/fluorescence trimodal imaging.

Authors:  Sihan Xue; Yao Wang; Mengxing Wang; Lu Zhang; Xiaoxia Du; Hongchen Gu; Chunfu Zhang
Journal:  Int J Nanomedicine       Date:  2014-05-21

9.  A robust and versatile signal-on fluorescence sensing strategy based on SYBR Green I dye and graphene oxide.

Authors:  Huazhang Qiu; Namei Wu; Yanjie Zheng; Min Chen; Shaohuang Weng; Yuanzhong Chen; Xinhua Lin
Journal:  Int J Nanomedicine       Date:  2014-12-22

10.  Transferrin-targeted magnetic/fluorescence micelles as a specific bi-functional nanoprobe for imaging liver tumor.

Authors:  Hui Qi; Zhengzheng Li; Kai Du; Ketao Mu; Qing Zhou; Shuyan Liang; Wenzhen Zhu; Xiangliang Yang; Yanhong Zhu
Journal:  Nanoscale Res Lett       Date:  2014-10-30       Impact factor: 4.703

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.