Literature DB >> 24362927

Design and characterization of an optimized simultaneous color and near-infrared fluorescence rigid endoscopic imaging system.

Vivek Venugopal1, Minho Park2, Yoshitomo Ashitate3, Florin Neacsu1, Frank Kettenring1, John V Frangioni4, Sidhu P Gangadharan5, Sylvain Gioux1.   

Abstract

We report the design, characterization, and validation of an optimized simultaneous color and near-infrared (NIR) fluorescence rigid endoscopic imaging system for minimally invasive surgery. This system is optimized for illumination and collection of NIR wavelengths allowing the simultaneous acquisition of both color and NIR fluorescence at frame rates higher than 6.8 fps with high sensitivity. The system employs a custom 10-mm diameter rigid endoscope optimized for NIR transmission. A dual-channel light source compatible with the constraints of an endoscope was built and includes a plasma source for white light illumination and NIR laser diodes for fluorescence excitation. A prism-based 2-CCD camera was customized for simultaneous color and NIR detection with a highly efficient filtration scheme for fluorescence imaging of both 700- and 800-nm emission dyes. The performance characterization studies indicate that the endoscope can efficiently detect fluorescence signal from both indocyanine green and methylene blue in dimethyl sulfoxide at the concentrations of 100 to 185 nM depending on the background optical properties. Finally, we performed the validation of this imaging system in vivo during a minimally invasive procedure for thoracic sentinel lymph node mapping in a porcine model.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24362927      PMCID: PMC3875528          DOI: 10.1117/1.JBO.18.12.126018

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  48 in total

Review 1.  Image-guided surgery in head and neck cancer: current practice and future directions of optical imaging.

Authors:  S Keereweer; H J C M Sterenborg; J D F Kerrebijn; P B A A Van Driel; R J Baatenburg de Jong; C W G M Löwik
Journal:  Head Neck       Date:  2011-01-31       Impact factor: 3.147

Review 2.  Lymph node dissection for lung cancer: significance, strategy, and technique.

Authors:  Shun-ichi Watanabe; Hisao Asamura
Journal:  J Thorac Oncol       Date:  2009-05       Impact factor: 15.609

3.  Near-infrared fluorescence imaging in patients undergoing pancreaticoduodenectomy.

Authors:  M Hutteman; J R van der Vorst; J S D Mieog; B A Bonsing; H H Hartgrink; P J K Kuppen; C W G M Löwik; J V Frangioni; C J H van de Velde; A L Vahrmeijer
Journal:  Eur Surg Res       Date:  2011-06-30       Impact factor: 1.745

Review 4.  A review of NIR dyes in cancer targeting and imaging.

Authors:  Shenglin Luo; Erlong Zhang; Yongping Su; Tianmin Cheng; Chunmeng Shi
Journal:  Biomaterials       Date:  2011-07-02       Impact factor: 12.479

5.  Fluorescence lifetime imaging microscopy for brain tumor image-guided surgery.

Authors:  Yinghua Sun; Nisa Hatami; Matthew Yee; Jennifer Phipps; Daniel S Elson; Fredric Gorin; Rudolph J Schrot; Laura Marcu
Journal:  J Biomed Opt       Date:  2010 Sep-Oct       Impact factor: 3.170

6.  Concurrent video-rate color and near-infrared fluorescence laparoscopy.

Authors:  Jürgen Glatz; Júlia Varga; Pilar Beatriz Garcia-Allende; Maximilian Koch; Florian R Greten; Vasilis Ntziachristos
Journal:  J Biomed Opt       Date:  2013-10       Impact factor: 3.170

7.  Near-infrared (NIR) laparoscopy for intraoperative lymphatic road-mapping and sentinel node identification during definitive surgical resection of early-stage colorectal neoplasia.

Authors:  Ronan A Cahill; Mark Anderson; Lai Mun Wang; Ian Lindsey; Chris Cunningham; Neil J Mortensen
Journal:  Surg Endosc       Date:  2011-08-19       Impact factor: 4.584

Review 8.  Fluorescence detection of bladder cancer: a review.

Authors:  Marie-Ange D'Hallewin; Lina Bezdetnaya; François Guillemin
Journal:  Eur Urol       Date:  2002-11       Impact factor: 20.096

9.  First-in-human pilot study of a spatial frequency domain oxygenation imaging system.

Authors:  Sylvain Gioux; Amaan Mazhar; Bernard T Lee; Samuel J Lin; Adam M Tobias; David J Cuccia; Alan Stockdale; Rafiou Oketokoun; Yoshitomo Ashitate; Edward Kelly; Maxwell Weinmann; Nicholas J Durr; Lorissa A Moffitt; Anthony J Durkin; Bruce J Tromberg; John V Frangioni
Journal:  J Biomed Opt       Date:  2011-08       Impact factor: 3.170

10.  The FLARE intraoperative near-infrared fluorescence imaging system: a first-in-human clinical trial in breast cancer sentinel lymph node mapping.

Authors:  Susan L Troyan; Vida Kianzad; Summer L Gibbs-Strauss; Sylvain Gioux; Aya Matsui; Rafiou Oketokoun; Long Ngo; Ali Khamene; Fred Azar; John V Frangioni
Journal:  Ann Surg Oncol       Date:  2009-07-07       Impact factor: 5.344

View more
  14 in total

1.  Target-to-background enhancement in multispectral endoscopy with background autofluorescence mitigation for quantitative molecular imaging.

Authors:  Chenying Yang; Vivian W Hou; Emily J Girard; Leonard Y Nelson; Eric J Seibel
Journal:  J Biomed Opt       Date:  2014       Impact factor: 3.170

2.  Image overlay solution based on threshold detection for a compact near infrared fluorescence goggle system.

Authors:  Shengkui Gao; Suman B Mondal; Nan Zhu; RongGuang Liang; Samuel Achilefu; Viktor Gruev
Journal:  J Biomed Opt       Date:  2015-01       Impact factor: 3.170

3.  Rapid pathology of lumpectomy margins with open-top light-sheet (OTLS) microscopy.

Authors:  Ye Chen; Weisi Xie; Adam K Glaser; Nicholas P Reder; Chenyi Mao; Suzanne M Dintzis; Joshua C Vaughan; Jonathan T C Liu
Journal:  Biomed Opt Express       Date:  2019-02-19       Impact factor: 3.732

4.  Multicolor fluorescence imaging using a single RGB-IR CMOS sensor for cancer detection with smURFP-labeled probiotics.

Authors:  Gyungseok Oh; Hong Jun Cho; SeungBeum Suh; Deukhee Lee; Keri Kim
Journal:  Biomed Opt Express       Date:  2020-05-08       Impact factor: 3.732

5.  Real-time endoscopic optical properties imaging.

Authors:  Joseph P Angelo; Martijn van de Giessen; Sylvain Gioux
Journal:  Biomed Opt Express       Date:  2017-10-19       Impact factor: 3.732

6.  Real-Time Visualization of Tissue Surface Biochemical Features Derived From Fluorescence Lifetime Measurements.

Authors:  Dimitris Gorpas; Dinglong Ma; Julien Bec; Diego R Yankelevich; Laura Marcu
Journal:  IEEE Trans Med Imaging       Date:  2016-02-15       Impact factor: 10.048

7.  In vivo fluorescence imaging of hepatocellular carcinoma xenograft using near-infrared labeled epidermal growth factor receptor (EGFR) peptide.

Authors:  Z Li; Q Zhou; J Zhou; X Duan; J Zhu; T D Wang
Journal:  Biomed Opt Express       Date:  2016-08-01       Impact factor: 3.732

8.  Intraoperative Near-Infrared Fluorescence Imaging of Thymus in Preclinical Models.

Authors:  Hideyuki Wada; Hoon Hyun; Homan Kang; Julien Gravier; Maged Henary; Mark W Bordo; Hak Soo Choi; John V Frangioni
Journal:  Ann Thorac Surg       Date:  2016-12-10       Impact factor: 4.330

Review 9.  Real-Time Imaging of Brain Tumor for Image-Guided Surgery.

Authors:  Shuang Hu; Homan Kang; Yoonji Baek; Georges El Fakhri; Anren Kuang; Hak Soo Choi
Journal:  Adv Healthc Mater       Date:  2018-05-02       Impact factor: 9.933

10.  Electrically tunable fluidic lens imaging system for laparoscopic fluorescence-guided surgery.

Authors:  Davide Volpi; Iain D C Tullis; Paul R Barber; Edyta M Augustyniak; Sean C Smart; Katherine A Vallis; Borivoj Vojnovic
Journal:  Biomed Opt Express       Date:  2017-06-13       Impact factor: 3.562

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.