Metallic or bioabsorbable interference screw for graft fixation in anterior cruciate ligament (ACL) reconstruction?

Rocco Papalia1, Sebastiano Vasta, Stefano D'Adamio, Antonino Giacalone, Nicola Maffulli, Vincenzo Denaro.   

Abstract

BACKGROUND: Approximately 100,000 anterior cruciate ligament (ACL) reconstructions are performed in the USA each year. Interference screw fixation is considered the standard for rigid fixation of the graft and provides higher fixation strength compared with other devices such as staples or buttons. The present study summarizes the latest evidence comparing the effectiveness of the available classes of interference screws for fixation of ACL grafts. SOURCES: A comprehensive search of the CINAHL, PubMed, Google Scholar, Embase Biomedical databases and the Cochrane Central Registry of Controlled Trials was performed in March 2013. Twelve studies met our inclusion criteria. AREAS OF AGREEMENT: Most studies showed no intergroup difference in terms of outcomes measured with validated clinical scores such as IKDC (International Knee Documentation Committee), Lysholm score and Tegner activity level. There was no significant difference regarding range of motion. Knee stability as evaluated with pivot shift and KT arthrometer showed a significant difference only in one study, favouring metallic interference screws. Tunnel widening is much more evident and marked patients who underwent ACL reconstruction with bioabsorbable screws, with no influence on the final clinical results achieved. Complication rates between the two screw classes were similar. The average modified Coleman methodology score was 74.67. AREAS OF UNCERTAINTY/RESEARCH NEED: The data comparing the outcomes achieved by two different materials for fixation, bioabsorbable and metallic, to be used during single-bundle ACL reconstruction, showed no significant difference in the final patient outcomes, in terms of clinical scores, clinical evaluation and imaging.

Entities:  

Keywords:  ACL fixation; ACL reconstruction; bioabsorbable screw; metallic screw

Mesh:

Substances:

Year:  2013        PMID: 24357733     DOI: 10.1093/bmb/ldt038

Source DB:  PubMed          Journal:  Br Med Bull        ISSN: 0007-1420            Impact factor:   4.291


  8 in total

1.  A Comparison of Functional Outcomes After Metallic and Bioabsorbable Interference Screw Fixations in Arthroscopic ACL Reconstructions.

Authors:  Atmananda S Hegde; Deepak K Rai; Antony J Kannampilly
Journal:  J Clin Diagn Res       Date:  2014-04-15

2.  Resorbable screw and sheath versus resorbable interference screw and staples for ACL reconstruction: a comparison of two tibial fixation methods.

Authors:  Christian Carulli; Fabrizio Matassi; Stefano Soderi; Luigi Sirleo; Giovanni Munz; Massimo Innocenti
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-04-27       Impact factor: 4.342

3.  Press-fit fixation in anterior cruciate ligament reconstruction yields low graft failure and revision rates: a systematic review and meta-analysis.

Authors:  Ajaykumar Shanmugaraj; Mathepan Mahendralingam; Chetan Gohal; Nolan Horner; Nicole Simunovic; Volker Musahl; Kristian Samuelsson; Olufemi R Ayeni
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-08-12       Impact factor: 4.342

4.  The REVision Using Imaging to Guide Staging and Evaluation (REVISE) in ACL Reconstruction Classification.

Authors:  Darren de Sa; Raphael J Crum; Stephen Rabuck; Olufemi Ayeni; Asheesh Bedi; Michael Baraga; Alan Getgood; Scott Kaar; Eric Kropf; Craig Mauro; Devin Peterson; Dharmesh Vyas; Volker Musahl; Bryson P Lesniak
Journal:  J Knee Surg       Date:  2019-09-30       Impact factor: 2.757

5.  Computed Tomography Imaging of BioComposite Interference Screw After ACL Reconstruction With Bone-Patellar Tendon-Bone Graft.

Authors:  Brian Scrivens; Melissa A Kluczynski; Marc S Fineberg; Leslie J Bisson
Journal:  Orthop J Sports Med       Date:  2021-05-06

Review 6.  Anatomic Outside-In Reconstruction of the Anterior Cruciate Ligament Using Femoral Fixation with Metallic Interference Screw and Surgical Staples (Agrafe) in the Tibia: An Effective Low-Cost Technique.

Authors:  Ariel de Lima Diego; de Vasconcelos Stemberg Martins; Leite José Alberto Dias; Pinto Dilamar Moreira; Teixeira Rogério Beltrão; de Léo Álvaro Coelho; Silveira Leonardo de Lima; Gonçalves Romeu Krause; Gonçalves Marcelo Carvalho Krause; de Vasconcelos Ana Carolina Leite; Filho Carlos Frederico Dias Costa; de Lima Lana Lacerda
Journal:  Open Orthop J       Date:  2017-10-31

7.  Does thread shape affect the fixation strength of the bioabsorbable interference screws for anterior cruciate ligament reconstructions? A biomechanical study.

Authors:  Gerardo L Garcés; Oscar Martel; Alejandro Yánez; Alberto Cuadrado
Journal:  BMC Musculoskelet Disord       Date:  2019-02-08       Impact factor: 2.362

8.  Clinical and radiological outcome after anterior cruciate ligament reconstruction using the T-lock Osteotrans resorbable tendon anchor: early experience and midterm follow-up.

Authors:  Y Bangert; A Jaber; F Wünnemann; G Berrsche; N Streich; C Rehnitz; H Ott; A Barié
Journal:  BMC Musculoskelet Disord       Date:  2020-12-18       Impact factor: 2.362