Use of a pocket-sized ultrasound machine (PUM) for routine examinations in the third trimester of pregnancy.

S Galjaard1, S Baeck, L Ameye, T Bourne, D Timmerman, R Devlieger.   

Abstract

OBJECTIVES: To evaluate the application of a pocket-sized ultrasound machine (PUM) in a routine antenatal third-trimester scan compared with a high-specification ultrasound machine (HSUM).
METHODS: This was an observational cohort study of 53 unselected women who came for their routine third-trimester ultrasound scan. The first scan was performed by an experienced ultrasonographer on an HSUM for fetal growth, fetal wellbeing and placental location. A second experienced operator performed the measurements on the PUM. Both operators were blinded to the other's findings and measurement results.
RESULTS: Fifty-one patients were eligible and scanned at a median gestational age of 31 + 1 (range, 27 + 2 to 36 + 0) weeks. Mean pregestational body mass index was 22.9 ± 3.1 (range, 17.6-35.7) kg/m(2) . In the comparison between measurements made using the PUM and HSUM, perfect agreement was found for fetal position, fetal bladder and stomach visualization (all κ 1.0) and very good agreement was found for placental position (κ 0.86). Measurements of deepest vertical pocket correlated moderately (intraclass correlation coefficient (ICC) 0.38 (95% CI, 0.12-0.59); Bland-Altman bias, 2.43 (95% limits of agreement (LoA), -22.65 to 27.51)). For fetal growth measurements there was very good agreement for biparietal diameter (ICC, 0.93 (95% CI, 0.88-0.96), Bland-Altman bias, -1.06 (95% LoA, -5.07 to 2.95)), and good agreement for femur length (ICC, 0.66 (95% CI, 0.48-0.79), Bland-Altman bias 0.56 (95% LoA, -5.97 to 7.08)) and transcerebellar diameter (ICC, 0.65 (95% CI, 0.46-0.78), Bland-Altman bias, -0.84 (95% LoA, -7.77 to 6.09)).
CONCLUSION: A battery-driven PUM can be used in third-trimester obstetrics for routine assessment of fetal growth (biparietal diameter, transcerebellar diameter and femur length) and for assessment of fetal wellbeing.
Copyright © 2013 ISUOG. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  fetal growth; hand-scanner; pocket-sized; third trimester; ultrasound

Mesh:

Year:  2014        PMID: 24357339     DOI: 10.1002/uog.13285

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  3 in total

Review 1.  Point-of-care ultrasound in obstetrics and gynecology.

Authors:  Florian Recker; Eva Weber; Brigitte Strizek; Ulrich Gembruch; Susan Campbell Westerway; Christoph F Dietrich
Journal:  Arch Gynecol Obstet       Date:  2021-02-08       Impact factor: 2.344

2.  Color Doppler Ultrasonography to Evaluate Hypoechoic Areas in Pressure Ulcers: A Report of Two Cases.

Authors:  Koichi Yabunaka; Gojiro Nakagami; Tomomitsu Miyagaki; Sanae Sasaki; Chieko Hayashi; Hiromi Sanada
Journal:  J Med Ultrasound       Date:  2018-09-14

3.  Evaluating sensitivity and specificity of handheld point-of-care ultrasound testing for gynecologic pathology: a pilot study for use in low resource settings.

Authors:  Marika Toscano; Kam Szlachetka; Natalie Whaley; Loralei L Thornburg
Journal:  BMC Med Imaging       Date:  2020-10-27       Impact factor: 1.930

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.