Literature DB >> 24353401

Assessment of dry eye signs and symptoms and ocular tolerance of a preservative-free lacrimal substitute (Hylabak®) versus a preserved lacrimal substitute (Systane®) used for 3 months in patients after LASIK.

Yuri S Astakhov1, Sergei Y Astakhov1, Alla B Lisochkina1.   

Abstract

Laser-assisted in situ keratomileusis (LASIK) is commonly used to correct refractive defects. The procedure frequently results in dry eye symptoms, usually of short but sometimes longer duration. This study was designed to assess dry eye and ocular tolerability after LASIK in patients treated with a preservative-free lacrimal substitute (Hylabak®) or preserved lacrimal substitute (Systane®). In a single-center, investigator-masked, prospective, noninferiority, clinical study, patients undergoing LASIK surgery were randomized to receive Hylabak or Systane eye drops (one drop in each eye four times daily for 3 months). Fluorescein test scores were the primary efficacy variable and were similar on day 1 (mean 0.26 and 0.28 for Hylabak and Systane, respectively). At the final visit (day 84 ± 3) the fluorescein scores had improved to 0.11 and 0.04, respectively. The difference was not significant and thus noninferiority was established. A trend of more rapid improvement in the Hylabak group was evident. Both treatments were well tolerated and there were no serious adverse events, discontinuations for adverse events or other safety-related reasons, and no systemic adverse events. The results suggest that Hylabak is not less effective than Systane in reducing the symptoms of dry eye after LASIK surgery.

Entities:  

Keywords:  dry eye; hyaluronate; laser-assisted in situ keratomileusis

Year:  2013        PMID: 24353401      PMCID: PMC3862698          DOI: 10.2147/OPTH.S50446

Source DB:  PubMed          Journal:  Clin Ophthalmol        ISSN: 1177-5467


Introduction

Laser-assisted in situ keratomileusis (LASIK) is an effective procedure used to correct refractive errors such as myopia, hyperopia, and astigmatism. It provides fast and relatively painless recovery of vision, has a low probability of regression of refractive correction, is not associated with subepithelial haze, and has become a common ophthalmologic procedure.1 Although complications are generally uncommon, dry eye (either temporary or permanent) has been reported in relatively high proportions of patients (up to 75% according to some reports)2 and LASIK is a recognized risk factor for the development of dry eye.1,3–5 Moreover, LASIK surgery can cause changes in the corneal environment, such as decreased corneal sensation,2,6 decreased tear secretion and quality, decreased corneal epithelial integrity, and reduced conjunctival goblet cell density.7 Tear film stability may be adversely affected, resulting in dry eye symptoms in the 6 months following surgery.1,4,6,7 In most patients, dry eye following LASIK surgery is disturbing but temporary, although some patients continue to suffer symptoms. First-line treatment for post-LASIK dry eye includes the same therapies as for dry eye of other etiologies, ie, artificial tears (preferably preservative-free where available), punctal occlusion, warm compresses, lid massage, and scrubs where meibomian gland dysfunction is a feature and treatment of inflammation with short courses of topical corticosteroids or cyclosporine A. Hyaluronate is a naturally occurring glycosaminoglycan polysaccharide found in skin, connective tissue, the joints, and several components of the eye. Biological roles for hyaluronate appear to include lubricant and water-retaining functions, and it is present in human tear fluid.8 It is widely employed in medicine in cataract surgery, dry eye treatment, lubrication of the joints in rheumatology, and in a wide range of skin preparations and antiaging creams.9 Hyaluronate has physicochemical properties that make it a valuable component of tear replacement therapies for dry eye, including useful viscoelastic properties and mucoadhesivity. It also has a powerful ability to retain water and can heal corneal wounds.10–14 The efficacy of hyaluronate in the treatment of dry eye of various etiologies is well established.15–21 Hylabak® (Laboratoires Thea, Clermont Ferrand, France) is a preparation containing 0.15% hyaluronate presented in a preservative-free multidose dispenser system.22 Until recently, preservatives (usually benzalkonium) have been required to limit microbial degradation of ophthalmic preparations. However, convincing evidence has accumulated to show that such preservatives have detrimental effects on the ocular surface.23 In particular, tear film stability, goblet cell function, apoptosis of conjunctival cells, and oxidative and inflammatory processes are adversely affected.23 Such changes are particularly unwelcome in patients with dry eye, and the availability of topical treatments without preservative is an important milestone in the treatment of the condition.24 In addition to in vitro and in vivo evidence, clinical studies have confirmed the detrimental effects of preservatives in ocular preparations.25–27 Guidelines now recommend the elimination of preservative from topical dry eye products.24 Systane® (Alcon Laboratories, Fort Worth, TX, USA) lubricant eye drops comprise polyethylene glycol 400 (0.4%) and propylene glycol (0.3%) demulcents, with hydroxypropyl guar polymer (0.4%) as a gelling agent and polidronium chloride (0.001%) as a preservative. An important difference between Systane and Hylabak is the presence of preservative in Systane; this may be of more importance in clinical practice than the different polymers used in the respective products.24 A randomized, investigator-masked, prospective study showed this preparation to be effective in relieving symptoms of dry eye in 30 patients undergoing LASIK surgery.28 The objective of the present study was to assess signs and symptoms of dry eye after LASIK in patients treated with a preservative-free lacrimal substitute (Hylabak) compared with those treated with a preserved lacrimal substitute (Systane) after 3 months. Ocular tolerability of the products was also compared between the groups.

Materials and methods

The study was conceived as a randomized, single-center, investigator-masked, prospective, noninferiority, parallel-group clinical study of 3 months’ duration. Patients undergoing bilateral LASIK surgery were randomized to receive 0.15% sodium hyaluronate preservative-free eye drops (Hylabak, in the ABAK® [Laboratoires Thea] dispenser system) or reference eye drops comprising polyethylene glycol 400, propylene glycol, and 0.001% polidronium chloride as the preservative (Systane). Each treatment was administered as one drop in each eye four times daily for 3 months. Both eyes were evaluated and treated with the same type of eye drop. The study was conducted in compliance with Good Clinical Practice according to International Conference on Harmonisation guidelines, European directive 2001/20/CE, and the Declaration of Helsinki (2004). Ethical approval was granted by the ethics committee at the State Educational Establishment of Higher Professional Education, Saint Petersburg State Medical University and of the Federal Service for Surveillance of Healthcare and Social Development of the Russian Federation.

Study design

Treatments were prepared according to a randomization code list, and were allocated to patients in predetermined order. Qualifying patients were assigned a specific treatment number allocated in ascending order. Differences in the dispensing form of the two treatments rendered masking treatment from the patients impractical; consequently treatment allocation was masked only from the investigators. Compliance was assessed by direct questioning.

Study visits

Inclusion (day −7)

Patient inclusion was assessed 7 ± 1 days prior to LASIK surgery and the commencement of study treatment.

Surgery (day 0)

Patients who fulfilled all inclusion and exclusion criteria were randomly assigned to receive the test or reference product in their left and right eyes. Treatment was commenced on the day of surgery.

Follow-up visits

Patients were followed up the day after surgery and then at 28 and 84 days after surgery (±3 days). At each visit, the following parameters were assessed: patients’ sensation of ocular surface dryness (burning, stinging, feeling of dryness, sandy and/or gritty sensation, light sensitivity) global tolerance (patient assessment) global efficacy and tolerance (investigator) best corrected visual acuity slit-lamp examination fluorescein test tear break-up time lid-parallel conjunctival folds (LIPCOF) test29 adverse events compliance assessment. A slit-lamp examination was also performed at the inclusion visit (day −7) and prior to surgery on day 0.

Patients

Patients aged 20–55 years and scheduled to undergo surgery to correct myopia, astigmatism, hyperopia, or a combination thereof, who had stable glasses or contact lens prescriptions for at least 2 years and who had sufficient corneal thickness (≥480 μm) were eligible for inclusion. Exclusion criteria were herpetic keratitis, glaucoma, cataract, anomalies related to eye lids or eye lid malformation, blepharitis, allergies, corneal dystrophy, history of ocular surgery, procedures such as LASIK, laser epithelial keratomileusis, or photorefractive keratectomy, moderate or serious dry eye, red eyes, keratoconus, any contraindication to LASIK surgery, known hypersensitivity to any component of the study medication, pregnancy, and premenopausal with no reliable method of birth control. Further grounds for exclusion were any medical or surgical history, disorder, or severe acute or chronic organic disease (eg, hepatic, endocrine, neoplastic, hematologic, immunosuppressive, infectious, severe psychiatric, or relevant cardiovascular abnormality), and/or any complicating or structural factor judged by the investigator to be incompatible with the study. Noncompliant patients, those unwilling or unable to give informed consent, those involved in a clinical trial in the previous 3 months, and those who were wards of the court were also excluded. Patients were similarly excluded if they had undergone ocular surgery during the previous 12 months, as were those who had received systemic nonsteroidal anti-inflammatory drugs, immunosuppressants, corticoids, or any medication that could interfere with lacrimal function during the 3 weeks prior to the study. No medications were permitted during the study period with the exception of drugs required in the surgical protocol (paracetamol, tobramycin, povidone-iodine, oxybuprocaine, and dexamethasone-neomycin-polymyxin B at approved doses).

Efficacy evaluation

The primary efficacy variable was reduction in mean score on the fluorescein test, evaluated using the Oxford scale,30 from day 1 to day 84 ± 3 in the worst eye in the per protocol population. A noninferiority test at the alpha level of 5% was applied to test the difference in mean change in score between the treatment groups, the null hypothesis being that 0.15% hyaluronate eye drops was more than 10% inferior to Systane eye drops. The secondary efficacy parameters were: ophthalmologic (including slit-lamp) examination in both eyes for meibomitis or other blepharitis (evaluated on a 0–3 scale) ocular symptoms, including sensation of dryness, burning or stinging sensations, sandy or gritty sensations, and photosensitivity were evaluated by the patient on a 0–3 scale LIPCOF test (degree of severity of dryness syndrome was scored on a scale of 0 [no parallel fold] to 3 [several parallel folds] with height >0.2 mm) best corrected visual acuity assessed using a Snellen chart global efficacy assessed by the investigator on a 0–3 scale tear film break-up time.

Assessment of safety

Safety was evaluated by global tolerance as assessed by the investigator (on a 0–3 scale) and patient questioning (“Are the eye drops comfortable?”, answered as “yes” or “no”). Ocular adverse events were recorded at all visits except on the recruitment visit (day −7). All adverse events regardless of severity that occurred between recruitment and completion were recorded, including at least a description of onset, duration, intensity, treatment required, outcome relationship to study medication, and narrative from the investigator.

Compliance and concomitant medication

Patients were questioned regarding compliance and concomitant medication at each visit after commencement of the study medication.

Statistical methods

A sample size of 42 subjects per arm was calculated to be necessary to provide an 80% probability of detecting a difference of 1 unit in mean score between the groups where the standard deviation of the scores was 2 units, the noninferiority margin was 10%, and the probability of type I error was 5%. Because each eye was to be evaluated individually and to allow for loss to follow-up, a target recruitment of 60 subjects was defined (60 eyes per arm). Noninferiority for the primary efficacy variable was considered established if the lower boundary of the 95% confidence interval (CI) for the difference in means between the two treatment groups calculated at day 84 was greater than −10%. Secondary efficacy variables were presented using descriptive statistics. Continuous efficacy variables were analyzed using the unpaired Student’s t-test and categorical efficacy variables using the chi-square test.

Results

Patient disposition and demographics

Fifty-four patients were screened and enrolled in the study, all of whom were randomized. Two patients were lost from the Systane group (one for a nonmedical reason and the other was lost to follow-up). Thus, the per protocol population comprised 27 patients in the Hylabak group and 25 patients in the Systane group (Figure 1). There were no protocol deviations and no withdrawals due to adverse events or lack of efficacy. Patient demographics and baseline characteristics are shown in Table 1. There were no statistically significant differences between the groups with regard to demographic parameters or baseline characteristics. There was a preponderance of females in both treatment groups.
Figure 1

Patient disposition.

Notes: Manufacturers details—Hylabak® (Laboratoires Thea, Clermont Ferrand, France); Systane® (Alcon Laboratories, Fort Worth, TX, USA).

Abbreviations: ITT, intention to treat; PP, per protocol.

Table 1

Patient demographics and baseline characteristics

ParameterHylabak® (n = 27)Systane® (n = 27)
Mean age ± standard deviation, years32 ± 930 ± 9
Sex
 Male (%)11 (41%)11 (41%)
 Female (%)16 (59%)16 (59%)

Notes: Manufacturers details—Hylabak® (Laboratoires Thea, Clermont Ferrand, France); Systane® (Alcon Laboratories, Fort Worth, TX, USA).

Primary efficacy variable

Fluorescein test scores were similar on day 1 (mean 0.26, 95% CI 0.11–0.41 and mean 0.28, 95% CI 0.12–0.44 for Hylabak and Systane, respectively). At the final visit (day 84 ± 3) the fluorescein scores had improved to 0.11 (95% CI 0.01–0.22) and 0.04 (95% CI −0.03 to 0.11), respectively. The improvement in fluorescein test score between baseline and day 84 ± 3 was statistically significant for Systane (P = 0.0308) but not for Hylabak; the difference between the two groups was not statistically significant, and noninferiority was achieved for Hylabak. The primary efficacy results are shown in Figure 2 and presented in full in Table 2.
Figure 2

Fluorescein test (Oxford scheme) score in the worst eye (per protocol sample).

Notes: Manufacturers details—Hylabak® (Laboratoires Thea, Clermont Ferrand, France); Systane® (Alcon Laboratories, Fort Worth, TX, USA).

Abbreviation: CI, confidence interval.

Table 2

Fluorescein test (Oxford scheme) score in the worst eye for per protocol population

Parameter/gradeHylabak® (n = 27)
Systane® (n = 25)
Visit 1 (day −7 ± 1)Visit 3 (baseline, day 1)Visit 4 (day 28 ± 3)Visit 5 (day 84 ± 3)Visit 1 (day −7 ± 1)Visit 3 (baseline, day 1)Visit 4 (day 28 ± 3)Visit 5 (day 84 ± 3)
Grade 0, n (%)19 (70.37)20 (74.07)25 (92.59)24 (88.89)21 (84)18 (72)21 (84)24 (96)
Grade 1, n (%)8 (29.63)7 (25.93)2 (7.41)3 (11.11)4 (16)7 (28)4 (16)1 (4)
Mean0.300.260.070.110.160.280.160.04
SD0.470.450.270.320.370.460.370.20
Median00000000
95% CI of mean0.14, 0.450.11, 0.41−0.01, 0.160.01, 0.220.03, 0.290.12, 0.440.03, 0.29−0.03, 0.11
Range, minimum, maximum0, 10, 10, 10, 10, 10, 10, 10, 1
Mean change−0.19−0.15−0.12−0.24
95% CI of mean change−0.34, −0.03−0.32, 0.03−0.27, 0.03−0.42, −0.06
P-value*0.05710.16120.18500.0308
P-value**0.25230.86940.34220.3460
Mean difference between groups0.0919
95% CI for difference in means between groups−0.09, 0.28

Notes: Percentages calculated based on number of eyes, in the worst eye of the corresponding treatment group

P-value for mean change was calculated using the paired t-test (two-tailed, α = 0.05)

P-value for mean change was calculated using the unpaired t-test (two-tailed, α = 0.05). Manufacturers details—Hylabak® (Laboratoires Thea, Clermont Ferrand, France); Systane® (Alcon Laboratories, Fort Worth, TX, USA).

Abbreviations: CI, confidence interval; SD, standard deviation.

The majority of the subjects in both groups were grade 0 at baseline (74.07% in the Hylabak group versus 72% in the Systane group). There was an improvement in both groups at day 84 (88.89% in the Hylabak group versus 96% in the Systane group). However, there was a trend (P = 0.0571) for a more rapid improvement in the Hylabak group than in the Systane group (reduction in the number of patients with grade 1 from 25.93% at baseline to 7.41% at day 28 in the Hylabak group versus a reduction from 25.93% to 14.81% in the Systane group).

Secondary efficacy variables

Ophthalmologic/slit-lamp examination

No subject in either group had palpebral signs (meibomitis), conjunctival discharge, chemosis, folliculopapillary conjunctivitis, filamentary keratitis, or conjunctival hyperemia at screening or during the study. Flap edema was present at baseline in two (7.41%) subjects (one with mild severity and the other with moderate severity) in the Hylabak group and in one (4%) subject (with mild severity) in the Systane group. No subjects had flap edema at the day 84 examination. One (3.7%) subject in the Hylabak group had mild but clinically nonsignificant flap folds at the day 84 examination.

Ocular symptoms

Improvement in ocular symptoms was observed in both groups during the study. In the Hylabak group, no subjects reported burning or stinging sensation. A sensation of dryness (3.7%), sandy and/or gritty feeling (11.11%), and photosensitivity (7.41%, score 1, not disturbing) were reported by very few subjects at baseline but not by any subject at days 28 and 84. In the Systane group, none of the subjects experienced stinging sensations. Similarly, burning sensation (8%), sandy and/or gritty sensation (12%), and photosensitivity (4%, score 1, not disturbing) were reported by very few subjects at baseline and none at days 28 and 84. A sensation of dryness was reported by two (8%) subjects at day 28 but by none at day 84.

LIPCOF test

Improvement in the severity of dry eye syndrome was observed in both groups during the study (Figure 3). In the Hylabak group, most of the subjects had either no parallel fold (55.56%) or one parallel fold (40.74%) at baseline. Improvement was seen at day 84, and 81.48% of subjects had no parallel fold; one subject in this group had severe parallel fold (score 3) at baseline and none had severe parallel fold at day 84. Similarly, in the Systane group at baseline, most of the subjects had either no parallel fold (64%) or one parallel fold (24%). Improvement was similarly observed at day 84, with most of the subjects (88%) having no parallel fold. None of the subjects in this group had severe parallel fold. The difference in LIPCOF test scores between the groups was not statistically significant (P > 0.05).
Figure 3

Evolution of LIPCOF score in the worst eye (per protocol population).

Notes: Manufacturers details—Hylabak® (Laboratoires Thea, Clermont Ferrand, France); Systane® (Alcon Laboratories, Fort Worth, TX, USA).

Abbreviation: LIPCOF, lid-parallel conjunctival folds.

Visual acuity

A majority of patients in each group had a best corrected visual acuity score of 6/6 in the worst eye at baseline (59.26% in the Hylabak group versus 64% in the Systane group). The proportion of subjects with a score of 6/6 in the worst eye improved from baseline in both groups; at day 84, 81.48% in the Hylabak group and 84% in the Systane group had a score of 6/6 in the worst eye. The difference between the treatment groups was not statistically significant (P > 0.05).

Global efficacy

The investigators rated a higher percentage of subjects in the Hylabak group to be “very satisfactory” than in the Systane group at day 1 through day 84 (Figure 4). One (3.7%) subject was reported as “not very satisfactory” at day 84 in the Hylabak group; two (8%) subjects on day 1 and one (4%) subject on day 28 were reported as “not very satisfactory” in the Systane group. Efficacy was assessed as “unsatisfactory” in only one (4%) subject at day 28 in the Systane group. Based on investigator rating, Hylabak was statistically superior to Systane on day 28 (P = 0.0113) but not on day 84 (P = 0.162).
Figure 4

Global efficacy assessment by investigator (per protocol population).

Notes: Manufacturers details—Hylabak® (Laboratoires Thea, Clermont Ferrand, France); Systane® (Alcon Laboratories, Fort Worth, TX, USA).

Tear film break-up time

Tear film break-up time had improved significantly from baseline (P < 0.0001) on day 84 in both groups. The difference between the groups in this regard was not statistically significant (P = 0.5619).

Safety

Fifty-two of the 54 enrolled subjects completed the study. There were no serious adverse events, no subject discontinued for adverse events or other safety-related reasons, and no adverse systemic events were reported. The safety population comprised all 54 randomized subjects. Overall, the study treatments were well tolerated, with only three adverse events (two of mild and one of moderate intensity) reported. All three adverse events were of corneal edema in both eyes. These comprised two adverse events (one mild and one moderate) in the Hylabak group and one adverse event (mild) in the Systane group. All three were assessed as unrelated to the study medication and were considered causally related to LASIK surgery. No systemic adverse events, serious adverse events, or deaths were reported during the course of the study. There were no discontinuations or withdrawals due to treatment-emergent adverse events. Both treatments were well tolerated by the study subjects. With the exception of one (3.7%) subject in the Hylabak group, all subjects reported the study treatments to be comfortable. The investigator rated tolerability as “not very satisfactory” for this subject. According to investigator assessment, a greater number of subjects scored “very satisfactory” in the Hylabak group than in the Systane group (62.96% each at day 28 and day 84, respectively, in the Hylabak group versus 37.04% each on day 28 and day 84, respectively, in the Systane group).

Discussion

The primary objective of the present study was to compare the effect of Hylabak and Systane eye drops on corneal fluorescein staining. The study indicates that Hylabak eye drops are not inferior to Systane eye drops and their overall efficacy appears to be similar, although there seem to be differences between treatments in terms of timing of the therapeutic effect. Both groups improved during the study; 74.07% and 72% of Hylabak patients and Systane patients, respectively, had grade 0 dry eye symptoms at baseline, a proportion that increased to 88.89% and 96%, respectively, by study completion. The reduction in fluorescein score from baseline to study end was statistically significant for Systane and the difference between the Hylabak and Systane groups was not. However, improvement in fluorescein staining seemed to be more rapid in the Hylabak group than in the Systane group. This trend toward a more rapid improvement in the Hylabak group compared with the Systane group was supported by other parameters. LIPCOF score and global efficacy assessment by the investigator were both reduced more at day 28 in the Hylabak group than in the Systane group. Clinical ocular signs were essentially absent at baseline and at study end. Although ocular symptoms of dry eye (sensation of dryness, sandy or gritty sensation, and photosensitivity) were relatively infrequent at baseline, the symptoms were reduced in both groups by the end of the study. The number of patients with an LIPCOF test score of 0 at study end was the same in Hylabak-treated and Systane-treated patients, but the scores in Hylabak-treated patients decreased more rapidly than in Systane-treated patients (percentage of patients with LIPCOF scores of 0 were 77.78% and 68%, respectively). However, the differences were small and did not reach statistical significance. Vision correction following laser surgery was similar in the two groups, as was tear film break-up time. Global efficacy as assessed by the investigator favored Hylabak at day 28; 66.67% of Hylabak-treated patients had a rating of “very satisfactory” compared with only 28% of Systane-treated patients, a difference that was statistically significant. Similarly, at day 84, 62.96% of Hylabak-treated patients had the highest rating for efficacy compared with 44% of Systane-treated patients, although this difference did not achieve statistical significance. Overall, the efficacy of the two treatments appears to be similar, and so far as the primary efficacy parameter is concerned, Hylabak is shown to be noninferior to Systane. There are some suggestions that Hylabak may act more rapidly than Systane, but more highly powered studies will be required to characterize the relative efficacy of the two preparations. Both treatments were well tolerated in this post-LASIK surgery population, even on the day after surgery. A number of topical treatments are used postoperatively in LASIK surgery patients (including antibiotics, anti-inflammatory drugs, and treatments for dry eye), and many of these formulations contain preservative. Several studies have demonstrated the cytotoxicity of preservatives,23 that increases with the duration of exposure, as well as the high prevalence of ocular disorders in patients treated with preserved eye drops.25 Since preservative-free products are now recommended for dry eye,24 the case for using them in the healing postoperative eye seems compelling. In conclusion, preservative-free Hylabak can be considered a welcome addition to the clinical armamentarium in dry eye for patients having recently undergone LASIK surgery and has been shown to be noninferior to Systane in this population. A preservative-free formulation is preferred for the treatment of dry eye, particularly in LASIK patients.
  29 in total

1.  Dry eye after laser in situ keratomileusis.

Authors:  I Toda; N Asano-Kato; Y Komai-Hori; K Tsubota
Journal:  Am J Ophthalmol       Date:  2001-07       Impact factor: 5.258

Review 2.  Management and therapy of dry eye disease: report of the Management and Therapy Subcommittee of the International Dry Eye WorkShop (2007).

Authors: 
Journal:  Ocul Surf       Date:  2007-04       Impact factor: 5.033

3.  Long term treatment with sodium hyaluronate-containing artificial tears reduces ocular surface damage in patients with dry eye.

Authors:  Pasquale Aragona; Vincenzo Papa; Antonio Micali; Marcello Santocono; Giovanni Milazzo
Journal:  Br J Ophthalmol       Date:  2002-02       Impact factor: 4.638

4.  Prospective, randomized comparison of self-reported postoperative dry eye and visual fluctuation in LASIK and photorefractive keratectomy.

Authors:  Yohko Murakami; Edward E Manche
Journal:  Ophthalmology       Date:  2012-08-11       Impact factor: 12.079

5.  Characterization of water retentive properties of hyaluronan.

Authors:  M Nakamura; M Hikida; T Nakano; S Ito; T Hamano; S Kinoshita
Journal:  Cornea       Date:  1993-09       Impact factor: 2.651

6.  [A comparative study of the ocular tolerance after administration of anti-allergic eye drops with or without a preservative].

Authors:  Cécile Beden; Laurent Helleboid; Farid Marmouz; François Liard
Journal:  Therapie       Date:  2004 Mar-Apr       Impact factor: 2.070

7.  Sodium hyaluronate (hyaluronic acid) promotes migration of human corneal epithelial cells in vitro.

Authors:  J A P Gomes; R Amankwah; A Powell-Richards; H S Dua
Journal:  Br J Ophthalmol       Date:  2004-06       Impact factor: 4.638

8.  The incidence and risk factors for developing dry eye after myopic LASIK.

Authors:  Cintia S De Paiva; Zhuo Chen; Douglas D Koch; M Bowes Hamill; Francis K Manuel; Sohela S Hassan; Kirk R Wilhelmus; Stephen C Pflugfelder
Journal:  Am J Ophthalmol       Date:  2006-03       Impact factor: 5.258

9.  Ocular symptoms and signs with preserved and preservative-free glaucoma medications.

Authors:  N Jaenen; C Baudouin; P Pouliquen; G Manni; A Figueiredo; T Zeyen
Journal:  Eur J Ophthalmol       Date:  2007 May-Jun       Impact factor: 2.597

10.  Use of containers with sterilizing filter in autologous serum eyedrops.

Authors:  José S López-García; Isabel García-Lozano
Journal:  Ophthalmology       Date:  2012-08-04       Impact factor: 12.079

View more
  4 in total

1.  The use of preservatives in dry eye drops.

Authors:  Karen Walsh; Lyndon Jones
Journal:  Clin Ophthalmol       Date:  2019-08-01

Review 2.  Impact of corneal refractive surgery on the precorneal tear film.

Authors:  Bhavana Sharma; Deepak Soni; Harsha Saxena; Louis J Stevenson; Samendra Karkhur; Brijesh Takkar; Rasik B Vajpayee
Journal:  Indian J Ophthalmol       Date:  2020-12       Impact factor: 1.848

3.  The Influence of Work Environment Factors on the OcularSurface in a One-Year Follow-Up Prospective Clinical Study.

Authors:  Edyta Chlasta-Twardzik; Aleksandra Górecka-Nitoń; Anna Nowińska; Edward Wylęgała
Journal:  Diagnostics (Basel)       Date:  2021-02-25

4.  Management of post-LASIK dry eye: a multicenter randomized comparison of a new multi-ingredient artificial tear to carboxymethylcellulose.

Authors:  Avi Wallerstein; W Bruce Jackson; Jeffrey Chambers; Amir M Moezzi; Hugh Lin; Peter A Simmons
Journal:  Clin Ophthalmol       Date:  2018-05-07
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.