Use of containers with sterilizing filter in autologous serum eyedrops.

José S López-García1, Isabel García-Lozano.   

Abstract

OBJECTIVE: To assess the effect of the use of containers with an adapted sterilizing filter on the contamination of autologous serum eyedrops.
DESIGN: Prospective, consecutive, comparative, and randomized study. PARTICIPANTS: Thirty patients with Sjögren syndrome.
METHODS: One hundred seventy-six autologous serum containers used in home therapy were studied; 48 of them included an adapted filter (Hyabak; Thea, Clermont-Ferrand, France), and the other 128 were conventional containers. Containers equipped with a filter were tested at 7, 14, 21, and 28 days of use, whereas conventional containers were studied after 7 days of use. In addition, testing for contamination was carried out in 14 conventional containers used during in-patient therapy every week for 4 weeks. In all cases, the preparation of the autologous serum was similar. Blood agar and chocolate agar were used as regular culture media for the microbiologic studies, whereas Sabouraud agar with chloramphenicol was the medium for fungal studies. MAIN OUTCOMES MEASURES: Microbiologic contamination of containers with autologous serum eyedrops.
RESULTS: Only one of the containers with an adapted sterilizing filter (2.1%) became contaminated with Staphylococcus epidermidis after 1 month of treatment, whereas the contamination rate among conventional containers reached 28.9% after 7 days of treatment. The most frequent germs found in the samples were coagulase-negative Staphylococcus (48.6%). With regard the containers used in the in-patient setting, 2 (14.3%) became contaminated after 2 weeks, 5 (35.7%) became contaminated after 3 weeks, and 5 (50%) became contaminated after 4 weeks, leaving 7 (50%) that did not become contaminated after 1 month of treatment.
CONCLUSIONS: Using containers with an adapted filter significantly reduces the contamination rates in autologous serum eyedrops, thus extending the use of such container by the patients for up to 4 weeks with virtually no contamination risks.
Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22867978     DOI: 10.1016/j.ophtha.2012.06.028

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  4 in total

1.  Assessment of dry eye signs and symptoms and ocular tolerance of a preservative-free lacrimal substitute (Hylabak®) versus a preserved lacrimal substitute (Systane®) used for 3 months in patients after LASIK.

Authors:  Yuri S Astakhov; Sergei Y Astakhov; Alla B Lisochkina
Journal:  Clin Ophthalmol       Date:  2013-12-09

2.  Evaluation of the efficacy of 50% autologous serum eye drops in different ocular surface pathologies.

Authors:  Francesco Semeraro; Eliana Forbice; Osvaldo Braga; Alessandro Bova; Attilio Di Salvatore; Claudio Azzolini
Journal:  Biomed Res Int       Date:  2014-07-22       Impact factor: 3.411

Review 3.  Application of Novel Drugs for Corneal Cell Regeneration.

Authors:  Sang Beom Han; Yu-Chi Liu; Karim Mohamed-Noriega; Jodhbir S Mehta
Journal:  J Ophthalmol       Date:  2018-05-02       Impact factor: 1.909

4.  Use of preservative-free hyaluronic acid (Hylabak(®)) for a range of patients with dry eye syndrome: experience in Russia.

Authors:  Vladimir Vsevolodovich Brjesky; Yury Fedorovich Maychuk; Alexey Vladimirovich Petrayevsky; Peter Gerrievich Nagorsky
Journal:  Clin Ophthalmol       Date:  2014-06-18
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.