Literature DB >> 24343858

Respiratory-gated noncontrast SPACE MR angiography sequence at 3T for evaluation of the central veins of the chest: a feasibility study.

Charles Y Kim1, Mustafa R Bashir, Tobias Heye, Brian M Dale, Holly L Nichols, Elmar M Merkle.   

Abstract

PURPOSE: To evaluate the feasibility of a respiratory-gated noncontrast magnetic resonance angiography (MRA) sequence for imaging the central veins of the chest.
MATERIALS AND METHODS: Eleven healthy subjects underwent MRA of the central veins of the chest with a respiratory-gated noncontrast (SPACE) sequence. Qualitative visualization and signal homogeneity of each central venous segment were scored by two radiologists on a scale of 1-4. Signal-to-noise and contrast-to-noise ratios (SNR and CNR) were also calculated. Retrospective review of our imaging database revealed 13 patients with suspected pathology of the central veins who underwent a clinical MRA examination using the SPACE sequence as well as reference standard central venous imaging with contrast-enhanced MRA or conventional venography.
RESULTS: In healthy subjects, all central venous segments demonstrated good to excellent venous visualization and homogeneity scores with the noncontrast SPACE sequence. The mean SNR and CNR of the central venous system were 192.7 and 175.0, respectively. In the 13 clinical examinations, the sensitivity and specificity for detection of stenosis or occlusions was 100% and 100% for reader 1 and 95% and 91% for reader 2, respectively.
CONCLUSION: The respiratory-gated noncontrast SPACE sequence provided excellent imaging characteristics of the central veins in healthy subjects with promising diagnostic accuracy in patients with central venous pathology.
© 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  MRA; SPACE; central veins; noncontrast

Mesh:

Year:  2013        PMID: 24343858     DOI: 10.1002/jmri.24540

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  4 in total

Review 1.  Intraoperative Imaging and Image Fusion for Venous Interventions.

Authors:  Ponraj Chinnadurai; Jean Bismuth
Journal:  Methodist Debakey Cardiovasc J       Date:  2018 Jul-Sep

2.  Assessment of thoracic vasculature in patients with central bronchogenic carcinoma by unenhanced magnetic resonance angiography: comparison between 2D free-breathing TrueFISP, 2D breath-hold TrueFISP and 3D respiratory-triggered SPACE.

Authors:  Lili Wang; Peng Lv; Shuohui Yang; Mengsu Zeng; Jiang Lin
Journal:  J Thorac Dis       Date:  2017-06       Impact factor: 2.895

Review 3.  SCMR Position Paper (2020) on clinical indications for cardiovascular magnetic resonance.

Authors:  Tim Leiner; Jan Bogaert; Matthias G Friedrich; Raad Mohiaddin; Vivek Muthurangu; Saul Myerson; Andrew J Powell; Subha V Raman; Dudley J Pennell
Journal:  J Cardiovasc Magn Reson       Date:  2020-11-09       Impact factor: 5.364

4.  Paget-Schroetter syndrome: An unfamiliar cause of upper-limb deep venous thrombosis.

Authors:  Bhushan Sudhakar Wankhade; Adel Elsaid ElKhouly; Zeyad Faoor Alrais; Mohamed Hamed Ibrahim Ali El Kholi
Journal:  Int J Crit Illn Inj Sci       Date:  2022-03-24
  4 in total