| Literature DB >> 24340058 |
Takayuki Shiroyama1, Norio Okamoto, Hidekazu Suzuki, Motohiro Tamiya, Tadahiro Yamadori, Naoko Morishita, Tomoyuki Otsuka, Satomu Morita, Kanako Kurata, Akira Okimura, Kunimitsu Kawahara, Shinji Sasada, Tomonori Hirashima, Ichiro Kawase.
Abstract
INTRODUCTION: The optimal suction pressure during endobronchial ultrasound guided transbronchial needle aspiration (EBUS-TBNA) remains to be determined. The aim of this study was to compare suction pressures for performance in collecting sufficient tissue specimens from mediastinal and hilar lymph nodes during EBUS-TBNA.Entities:
Mesh:
Year: 2013 PMID: 24340058 PMCID: PMC3855538 DOI: 10.1371/journal.pone.0082787
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Figure 1Suction pressure devices.
The upper syringe is a dedicated VacLok 20 mL syringe, as used in group C, and the lower syringe is a disposable 30 mL syringe, as used in group H.
Figure 2Flowchart of the 178 patients who underwent EBUS-TBNA.
Others included bronchogenic cyst, tuberculous lymphadenitis, inflammatory myofibroblastic tumor and leiomyoma. The determination of benign diseases was based on results of clinical follow-up of at least 6 months demonstrating reduction in size or lack of apparent radiologic disease progression.
Characteristics of patients who were initially diagnosed with lung cancer by EBUS-TBNA (n = 131).
|
|
|
| |
|---|---|---|---|
|
| 0.07 | ||
| Median (range) | 65(51-82) | 69(42-87) | |
|
| 0.46 | ||
| Female | 5(14%) | 20(21%) | |
| Male | 30(86%) | 76(79%) | |
|
| 0.70 | ||
| Adenocarcinoma | 11(31%) | 40(42%) | |
| Squamous cell carcinoma | 8(23%) | 24 | |
| Small cell carcinoma | 13(37%) | 26(27%) | |
| Large cell carcinoma | 1(3%) | 2(2%) | |
| NSCLC- NOS | 2(6%) | 4(4%) | |
|
| 0.14 | ||
| 2R | 3(9%) | 1(1%) | |
| 4R | 7(20%) | 32(33%) | |
| 4L | 3(9%) | 5(5%) | |
| 7 | 12(34%) | 35(37%) | |
| Others | 10(28%) | 23(24%) | |
|
| 0.56 | ||
| 1 station | 32(91%) | 82(85%) | |
| 2 stations ≤ | 3(9%) | 14(15%) | |
|
| |||
| Short axis | 23.7(11.3-49.0) | 20.9(10.1-39.4) | 0.13 |
| Long axis | 28.5(16.0-55.1) | 27.2(13.2-49.2) | 0.15 |
By Mann-Whitney U test. By Fisher’s exact test. Including 1 patient with combined squamous and small cell carcinoma. Size of the largest LN station on computed tomography.
Abbreviations: NSCLC- NOS, Non-small cell lung carcinoma- not otherwise specified; LN, Lymph node; CT, Computed Tomography.
Sensitivity, specificity, and rates of diagnostic accuracy of EBUS-TBNA.
|
|
| |
|---|---|---|
|
| 92.3 % | 94.2 % |
|
| 100 % | 100 % |
|
| 94.2 % | 95.1 % |
There was no significant difference between group C and group H.
Diagnostic method according to group.
|
|
|
| |
|---|---|---|---|
|
| 0.04[ | ||
| Cytology alone | 7 | 6 | |
| Cytology and Histology | 28 | 90 |
a By Fisher’s exact test.
There was a statistically significant difference between group C and group H in terms of the rate of sampling of sufficient histological specimens.