BACKGROUND: In critically ill children, monitoring of cardiac output (CO) is essential to guide haemodynamic management and facilitate cardiovascular therapy. The ultrasound dilution technique (UDT), a novel minimally invasive indicator method, was recently introduced to determine CO. We validated UDT against the 'gold standard' reference technique, the direct Fick principle, in infants and children. METHODS: Twenty-six children (median age: 6 yr 2 months; median weight: 19.2 kg) underwent diagnostic heart catheterization. In each child, CO was determined by the Fick principle using direct measurement of oxygen consumption and invasive oximetry. Consecutively, haemodynamically stable conditions provided; three independent measurements of CO were conducted with UDT. CO values were compared using bias and limits of agreement calculated using the Bland-Altman approach and linear regression analysis for the complete study group and for a subgroup with body weight <20 kg (n=14). RESULTS: The mean (standard deviation) CO values were 3.76 (1.73) litre min(-1) (range 1.38-6.97) for the direct Fick principle and 3.49 (1.72) litre min(-1) (range 1.31-7.00) for UDT. An excellent correlation (r=0.96) was found between both methods (P<0.0001). The Bland-Altman analysis demonstrated good clinical agreement with a mean bias of 0.26 litre min(-1), limits of agreement of -0.66 and 1.19 litre min(-1), and percentage error of 25.9%. Comparable results were obtained for patients <20 kg (mean bias=0.19 litre min(-1), percentage error=25.5%). CONCLUSIONS: CO measurements by UDT agree favourably with Fick-derived CO data and both techniques were found to be equivalent and interchangeable. UDT represents a valid and applicable method for repetitive CO determinations in infants and children.
BACKGROUND: In critically ill children, monitoring of cardiac output (CO) is essential to guide haemodynamic management and facilitate cardiovascular therapy. The ultrasound dilution technique (UDT), a novel minimally invasive indicator method, was recently introduced to determine CO. We validated UDT against the 'gold standard' reference technique, the direct Fick principle, in infants and children. METHODS: Twenty-six children (median age: 6 yr 2 months; median weight: 19.2 kg) underwent diagnostic heart catheterization. In each child, CO was determined by the Fick principle using direct measurement of oxygen consumption and invasive oximetry. Consecutively, haemodynamically stable conditions provided; three independent measurements of CO were conducted with UDT. CO values were compared using bias and limits of agreement calculated using the Bland-Altman approach and linear regression analysis for the complete study group and for a subgroup with body weight <20 kg (n=14). RESULTS: The mean (standard deviation) CO values were 3.76 (1.73) litre min(-1) (range 1.38-6.97) for the direct Fick principle and 3.49 (1.72) litre min(-1) (range 1.31-7.00) for UDT. An excellent correlation (r=0.96) was found between both methods (P<0.0001). The Bland-Altman analysis demonstrated good clinical agreement with a mean bias of 0.26 litre min(-1), limits of agreement of -0.66 and 1.19 litre min(-1), and percentage error of 25.9%. Comparable results were obtained for patients <20 kg (mean bias=0.19 litre min(-1), percentage error=25.5%). CONCLUSIONS: CO measurements by UDT agree favourably with Fick-derived CO data and both techniques were found to be equivalent and interchangeable. UDT represents a valid and applicable method for repetitive CO determinations in infants and children.
Entities:
Keywords:
cardiac output; children; direct Fick principle; ultrasound dilution technique
Authors: Martin Boehne; Mathias Baustert; Verena Paetzel; Dietmar Boethig; Harald Köditz; Nils Dennhardt; Philipp Beerbaum; Harald Bertram Journal: Pediatr Cardiol Date: 2016-11-08 Impact factor: 1.655
Authors: Javier Urbano; Jorge López; Rafael González; María José Solana; Sarah N Fernández; José M Bellón; Jesús López-Herce Journal: Pediatr Cardiol Date: 2014-09-02 Impact factor: 1.655
Authors: Javier Urbano; Jorge López; Rafael González; Sarah N Fernández; María José Solana; Blanca Toledo; Ángel Carrillo; Jesús López-Herce Journal: Intensive Care Med Exp Date: 2016-06-03