Literature DB >> 24333933

A novel fluorescent nanosensor for detection of heparin and heparinase based on CuInS2 quantum dots.

Ziping Liu1, Qiang Ma1, Xinyan Wang2, Zihan Lin1, Hao Zhang1, Linlin Liu1, Xingguang Su3.   

Abstract

In this work, a novel fluorescence "turn off-on" nanosensor for the determination of heparin and heparinase based on CuInS2 quantum dots (QDs) was established. CuInS2 QDs (modified by l-cysteine) featuring amino groups were directly prepared in aqueous solution via a hydrothermal synthesis method. The amino groups on the surface of CuInS2 QDs can interact with sulfate and carboxylate groups in heparin via electrostatic interactions and hydrogen bonding, which led the fluorescence of CuInS2 QDs to "turn-off". However, the heparin could be hydrolyzed into small fragments in the presence of heparinase, which resulted in the fluorescence of CuInS2 QDs being recovered. Therefore, the addition of heparinase to the heparin/CuInS2 QDs system activated the fluorescence of CuInS2 QDs to "turn-on" state. Thus, the determination of heparin and heparinase could be achieved by monitoring the fluorescence "turn off-on". Under the optimum conditions, there was a good linear relationship between I/I0 (I and I0 were the fluorescence intensity of CuInS2 QDs in the presence and absence of heparin, respectively) and heparin concentration in the range of 0.05-15 μmol L(-1) with the detection limit of 12.46 nmol L(-1). The linear detection for heparinase was in the range of 0.2-5 μg mL(-1) with the detection limit of 0.07 μg mL(-1). The proposed nanosensor was employed for the detection of heparin in fetal bovine serum samples with satisfactory results.
© 2013 The Authors. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  CuInS(2) QDs; Electrostatic interaction; Fluorescence “turn off–on”; Heparin; Heparinase; Nanosensor

Mesh:

Substances:

Year:  2013        PMID: 24333933     DOI: 10.1016/j.bios.2013.11.050

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

1.  Colorimetric and fluorometric aggregation-based heparin assay by using gold nanoclusters and gold nanoparticles.

Authors:  Zhipeng Zhang; Sha Li; Pengcheng Huang; Jiayu Feng; Fang-Ying Wu
Journal:  Mikrochim Acta       Date:  2019-11-16       Impact factor: 5.833

2.  Enhanced Photoacoustic Detection of Heparin in Whole Blood via Melanin Nanocapsules Carrying Molecular Agents.

Authors:  Wonjun Yim; Kathryn Takemura; Jiajing Zhou; Jingcheng Zhou; Zhicheng Jin; Raina M Borum; Ming Xu; Yong Cheng; Tengyu He; William Penny; Bill R Miller; Jesse V Jokerst
Journal:  ACS Nano       Date:  2021-12-28       Impact factor: 18.027

3.  A ratiometric fluorometric heparin assay based on the use of CdTe and polyethyleneimine-coated carbon quantum dots.

Authors:  Si-Si Liang; Xu Deng; Yao-Yao Fan; Jun Li; Man Wang; Zhi-Qi Zhang
Journal:  Mikrochim Acta       Date:  2018-10-25       Impact factor: 5.833

Review 4.  Ternary Quantum Dots in Chemical Analysis. Synthesis and Detection Mechanisms.

Authors:  Raybel Muñoz; Eva M Santos; Carlos A Galan-Vidal; Jose M Miranda; Aroa Lopez-Santamarina; Jose A Rodriguez
Journal:  Molecules       Date:  2021-05-08       Impact factor: 4.411

  4 in total