Literature DB >> 24332951

Surgical fixation of extra-articular distal humerus fractures with a posterolateral plate through a triceps-reflecting technique.

John A Scolaro1, Pramod Voleti2, Amun Makani2, Surena Namdari3, Amer Mirza4, Samir Mehta5.   

Abstract

BACKGROUND: Surgical management of extra-articular distal humerus fractures results in predictable fracture alignment. Open reduction and internal fixation also decrease the soft tissue complications and frequent follow-up required with functional bracing. A triceps-reflecting posterior approach provides excellent exposure to the humerus and minimizes trauma to the triceps. An anatomically precontoured plate on the posterolateral surface of the humerus provides stable fixation of these injuries and is placed directly through the interval developed by the triceps-reflecting approach.
METHODS: We retrospectively reviewed the trauma databases at 2 level I academic trauma institutions during a 5-year period for all patients with an extra-articular distal humerus fracture treated with a triceps-reflecting approach and an anatomically precontoured posterolateral distal humerus plate. Patient and fracture characteristics were recorded, as were QuickDASH functional scores and visual analog scale scores for pain, function, and quality of life.
RESULTS: Forty patients were eligible for our study. Average follow-up was 88 weeks. Thirty-eight (95%) patients went on to union. Seven (20%) patients required a secondary procedure. The average QuickDASH score was 17.5 (range, 2.6-56.8). The average visual analog scale scores were 1.9 (range, 0-7) for pain, 2.3 (range, 0-8) for function, and 1.6 (range, 0-5) for quality of life. Thirty-five (87.5%) patients reported satisfaction with the outcome of their surgery. DISCUSSION: Surgical fixation of extra-articular distal humerus fractures through a triceps-reflecting approach with an anatomically precontoured posterolateral distal humerus plate results in predictable osseous union and overall excellent functional results for patients with this injury.
Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

Entities:  

Keywords:  Case Series; Humeral fracture; Level IV; Treatment Study; distal humerus; extra-articular; posterolateral plate; triceps reflecting

Mesh:

Year:  2013        PMID: 24332951     DOI: 10.1016/j.jse.2013.09.020

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  10 in total

Review 1.  Best care paradigm to optimize functionality after extra-articular distal humeral fractures in the young patient.

Authors:  Mark S Ayoub; Ivan S Tarkin
Journal:  J Clin Orthop Trauma       Date:  2018-02-07

2.  Antero-lateral minimally invasive plate osteosynthesis (MIPO) with the radial nerve exploration for extra-articular distal-third diaphyseal fractures of the humerus.

Authors:  Wei Zhao; Wei Qu; Chongyang Fu; Huajun Jiang; Sida Liu; Chao Cheng
Journal:  Int Orthop       Date:  2017-06-02       Impact factor: 3.075

3.  Risk factors for hardware-related complications after extra-articular distal humerus fracture fixation using an anatomical locking plate.

Authors:  Hyoung-Seok Jung; Yoo-Sun Won; Yang-Seon Choi; Jae-Sung Lee
Journal:  Eur J Trauma Emerg Surg       Date:  2022-08-01       Impact factor: 2.374

4.  Retrospective analysis of extra-articular distal humerus shaft fractures treated with the use of pre-contoured lateral column metaphyseal LCP by triceps-sparing posterolateral approach.

Authors:  Yatinder Kharbanda; Yashwant Singh Tanwar; Vishal Srivastava; Vikas Birla; Ashok Rajput; Ramsagar Pandit
Journal:  Strategies Trauma Limb Reconstr       Date:  2016-11-03

5.  Outcome of anatomic locking plate in extraarticular distal humeral shaft fractures.

Authors:  Deepak Jain; Gurpreet S Goyal; Rajnish Garg; Pankaj Mahindra; Mohammad Yamin; Harpal S Selhi
Journal:  Indian J Orthop       Date:  2017 Jan-Feb       Impact factor: 1.251

6.  Outcome of Extra-Articular Distal Humerus Fractures Fixed by Single Column Extra-Articular Distal Humerus Locking Compression Plate Using Triceps Sparing Postero-Lateral Approach.

Authors:  Nadeem Ali; Naseer Ahmad Mir; Tahir Ahmad Dar; Mohmad Nawaz Rather; Wajahat Ahmad Mir; Senin S; Saheel Maajid
Journal:  Bull Emerg Trauma       Date:  2018-10

7.  Functional and Radiological Outcome in Distal Third Humerus Fracture Treated with Extra-articular Locking Plate: A Multicentric Retrospective Study.

Authors:  Ashis Kumar Gupta; Barada Prasanna Samal; Tushar Ranjan Dalei
Journal:  J Pharm Bioallied Sci       Date:  2021-11-10

8.  A NEW ANATOMICAL PLATE FOR EXTRA-ARTICULAR DISTAL HUMERAL FRACTURES: BIOMECHANICAL STUDY.

Authors:  Harun Mutlu; Abdulkadir Polat; Mehmet Ümit Çetin; Serhat Mutlu; Teyfik Demir; Atilla Sancar Parmaksizoğlu
Journal:  Acta Ortop Bras       Date:  2022-01-28       Impact factor: 0.513

9.  The evaluation of a de novo biplanar distal humerus plate: A biomechanical study.

Authors:  Nihat Acar; Ahmet Karakaşlı; Onur Gürsan; R Buğra Hüsemoğlu
Journal:  Jt Dis Relat Surg       Date:  2022-07-06

10.  Modified application of distal medial tibial locking plate as an alternative for fixation of an extraarticular distal-third diaphyseal humerus fracture.

Authors:  Babaji Thorat; Avtar Singh; Rajeev Vohra; Mohammad Arshad; Ravi Mavani
Journal:  Trauma Case Rep       Date:  2021-02-10
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.