Literature DB >> 24332815

The effect of guided flapless implant procedure on heat generation from implant drilling.

Seung-Mi Jeong1, Je-Hyeon Yoo1, Yiqin Fang1, Byung-Ho Choi2, Jeong-Seog Son1, Ji-Hyeon Oh1.   

Abstract

The objective of this study was to evaluate the heat generation in vitro during the flapless drilling procedure using surgical drill guides. Ten resin models with bilateral edentulous tooth spaces in the first and second molars in the mandible were used in this study. On one side of the mandible, drilling was performed with a flapless approach using a surgical drill guide. On the other side of the mandible, drilling was performed with a flap approach. The temperature changes were measured during final drilling by thermocouples. The mean maximum temperatures during drilling with guided flapless procedures were 29.5 °C and 32.6 °C at the depths of 3 and 6 mm, respectively, whereas for flap procedures they were 29.4 °C and 31.3 °C. There was no statistically significant difference between the groups. These findings suggest that drilling with external irrigation in an up-and-down pumping motion may not lead to a significant increase the bone temperature during a flapless procedure using surgical drill guides.
Copyright © 2013 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Dental implant; Drilling; Flapless; Surgical guide; Thermocouple

Mesh:

Substances:

Year:  2013        PMID: 24332815     DOI: 10.1016/j.jcms.2013.11.002

Source DB:  PubMed          Journal:  J Craniomaxillofac Surg        ISSN: 1010-5182            Impact factor:   2.078


  8 in total

Review 1.  Flapless dental implant surgery and use of cone beam computer tomography guided surgery.

Authors:  D P Laverty; J Buglass; A Patel
Journal:  Br Dent J       Date:  2018-04-06       Impact factor: 1.626

Review 2.  Heat Development During Medical Drilling: Influencing Factors and Examination Methods - Overview and First Results.

Authors:  Ole Jung; Carolin Lindner; Sven Pantermehl; Mike Barbeck
Journal:  In Vivo       Date:  2021 Nov-Dec       Impact factor: 2.155

3.  A survey of the satisfaction of patients who have undergone implant surgery with and without employing a computer-guided implant surgical template.

Authors:  Shin-Young Youk; Jee-Ho Lee; Ji-Man Park; Seong-Joo Heo; Hyun-Ki Roh; Eun-Jin Park; Im Hee Shin
Journal:  J Adv Prosthodont       Date:  2014-10-21       Impact factor: 1.904

4.  The effect of low-speed drilling without irrigation on heat generation: an experimental study.

Authors:  Ji-Hyeon Oh; Yiqin Fang; Seung-Mi Jeong; Byung-Ho Choi
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2016-02-15

5.  Comparison of the Bone Harvesting Capacity of an Intraoral Bone Harvesting Device and Three Different Implant Drills.

Authors:  Hyun-Chang Lim; Kyung-In Ha; Ji-Youn Hong; Ji-Young Han; Seung-Il Shin; Seung-Yun Shin; Yeek Herr; Jong-Hyuk Chung
Journal:  Biomed Res Int       Date:  2017-12-14       Impact factor: 3.411

6.  Comparison of peri-implant bone loss between conventional drilling with irrigation versus low-speed drilling without irrigation.

Authors:  H Pellicer-Chover; D Peñarrocha-Oltra; A Aloy-Prosper; J-C Sanchis-Gonzalez; M-A Peñarrocha-Diago; M Peñarrocha-Diago
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2017-11-01

7.  Minimally Invasive Ponto Surgery Versus the Linear Incision Technique With Soft Tissue Preservation for Bone Conduction Hearing Implants: A Multicenter Randomized Controlled Trial.

Authors:  Tim G A Calon; Martin L Johansson; Arthur J G de Bruijn; Herbert van den Berge; Mariet Wagenaar; Edwin Eichhorn; Miranda M L Janssen; Janny R Hof; Jan-Wouter Brunings; Manuela A Joore; Sofia Jonhede; Joost van Tongeren; Marcus Holmberg; Robert-Jan Stokroos
Journal:  Otol Neurotol       Date:  2018-08       Impact factor: 2.311

8.  Ridge augmentation-The new field of computerized guided surgery: A technical note for minimal-invasive bone splitting.

Authors:  Vasilios Alevizakos; Gergo Mitov; Marcus Schiller; Constantin von See
Journal:  Clin Case Rep       Date:  2021-03-20
  8 in total