Literature DB >> 24332170

3D CT cerebral angiography technique using a 320-detector machine with a time-density curve and low contrast medium volume: comparison with fixed time delay technique.

K Das1, S Biswas2, S Roughley1, M Bhojak1, S Niven1.   

Abstract

AIM: To describe a cerebral computed tomography angiography (CTA) technique using a 320-detector CT machine and a small contrast medium volume (35 ml, 15 ml for test bolus). Also, to compare the quality of these images with that of the images acquired using a larger contrast medium volume (90 or 120 ml) and a fixed time delay (FTD) of 18 s using a 16-detector CT machine.
MATERIALS AND METHODS: Cerebral CTA images were acquired using a 320-detector machine by synchronizing the scanning time with the time of peak enhancement as determined from the time-density curve (TDC) using a test bolus dose. The quality of CTA images acquired using this technique was compared with that obtained using a FTD of 18 s (by 16-detector CT), retrospectively. Average densities in four different intracranial arteries, overall opacification of arteries, and the degree of venous contamination were graded and compared.
RESULTS: Thirty-eight patients were scanned using the TDC technique and 40 patients using the FTD technique. The arterial densities achieved by the TDC technique were higher (significant for supraclinoid and basilar arteries, p < 0.05). The proportion of images deemed as having "good" arterial opacification was 95% for TDC and 90% for FTD. The degree of venous contamination was significantly higher in images produced by the FTD technique (p < 0.001%).
CONCLUSION: Good diagnostic quality CTA images with significant reduction of venous contamination can be achieved with a low contrast medium dose using a 320-detector machine by coupling the time of data acquisition with the time of peak enhancement.
Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24332170     DOI: 10.1016/j.crad.2013.10.021

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  2 in total

1.  Optimal scan timing for artery-vein separation at whole-brain CT angiography using a 320-row MDCT volume scanner.

Authors:  Takashi Shirasaka; Akio Hiwatashi; Koji Yamashita; Masatoshi Kondo; Hiroshi Hamasaki; Yamato Shimomiya; Yasuhiko Nakamura; Yoshinori Funama; Hiroshi Honda
Journal:  Br J Radiol       Date:  2016-12-20       Impact factor: 3.039

2.  Accuracy of four-dimensional CT angiography in detection and characterisation of arteriovenous malformations and dural arteriovenous fistulas.

Authors:  Shubhabrata Biswas; Arun Chandran; Mark Radon; Mani Puthuran; Maneesh Bhojak; Hans Christean Nahser; Kumar Das
Journal:  Neuroradiol J       Date:  2015-10-01
  2 in total