Literature DB >> 26427892

Accuracy of four-dimensional CT angiography in detection and characterisation of arteriovenous malformations and dural arteriovenous fistulas.

Shubhabrata Biswas1, Arun Chandran2, Mark Radon2, Mani Puthuran2, Maneesh Bhojak2, Hans Christean Nahser2, Kumar Das2.   

Abstract

A retrospective review was made to assess the accuracy of four dimensional CT angiogram (4D-CTA) in diagnosis of arteriovenous malformations (AVM) and dural arteriovenous fistulas (DAVF), with catheter-based digital-subtraction angiogram (DSA) being gold standard. 33 pairs of investigations (DSA and 4D-CTA) were performed primarily for suspicion of AVM/DAVF. Based on blinded reports, sensitivity and specificity for detection of AVM/DAVF were 77% (95% CI: 46-95%) and 100% (95% CI: 83-100%) respectively. Positive predictive value was 100% (95% CI: 69-100%) and negative predictive value 87% (95% CI: 66-97%). 4D-CTA is a practical minimally-invasive technique for evaluating cerebrovascular pathologies. There is good agreement between the findings of 4D-CTA and DSA despite the differences in temporal and spatial resolutions. 4D-CTA may obviate the need for DSA in a subgroup of patients who would otherwise have undergone this invasive investigation, which carries a risk of important complications.
© The Author(s) 2015.

Entities:  

Keywords:  Four-dimensional CT angiogram; arteriovenous malformation; digital subtraction angiography; dural arteriovenous fistula

Mesh:

Substances:

Year:  2015        PMID: 26427892      PMCID: PMC4757303          DOI: 10.1177/1971400915604526

Source DB:  PubMed          Journal:  Neuroradiol J        ISSN: 1971-4009


  32 in total

1.  Multisection dynamic CT perfusion for acute cerebral ischemia: the "toggling-table" technique.

Authors:  H C Roberts; T P Roberts; W S Smith; T J Lee; N J Fischbein; W P Dillon
Journal:  AJNR Am J Neuroradiol       Date:  2001 Jun-Jul       Impact factor: 3.825

2.  Multi-slice CT angiography in the evaluation of patients with acute cerebrovascular disease--a promising new diagnostic tool.

Authors:  Randolf Klingebiel; Markus Busch; Georg Bohner; Claus Zimmer; Olaf Hoffmann; Florian Masuhr
Journal:  J Neurol       Date:  2002-01       Impact factor: 4.849

Review 3.  Spontaneous intracranial hemorrhage: which patients need diagnostic cerebral angiography? A prospective study of 206 cases and review of the literature.

Authors:  X L Zhu; M S Chan; W S Poon
Journal:  Stroke       Date:  1997-07       Impact factor: 7.914

4.  Posterior fossa dural arteriovenous fistulas: diagnosis and follow-up with time-resolved imaging of contrast kinetics (TRICKS) at 1.5T.

Authors:  Johanna Pekkola; Marko Kangasniemi
Journal:  Acta Radiol       Date:  2011-03-09       Impact factor: 1.990

5.  Risk of cerebral angiography in patients with subarachnoid hemorrhage, cerebral aneurysm, and arteriovenous malformation: a meta-analysis.

Authors:  H J Cloft; G J Joseph; J E Dion
Journal:  Stroke       Date:  1999-02       Impact factor: 7.914

6.  Multi-section CT angiography for detection of cerebral aneurysms.

Authors:  Mehmet Teksam; Alexander McKinney; Sean Casey; Martin Asis; Stephen Kieffer; Charles L Truwit
Journal:  AJNR Am J Neuroradiol       Date:  2004-10       Impact factor: 3.825

Review 7.  Brain perfusion-CT in acute stroke patients.

Authors:  Max Wintermark
Journal:  Eur Radiol       Date:  2005-11       Impact factor: 5.315

Review 8.  Neurologic complications of cerebral angiography: prospective analysis of 2,899 procedures and review of the literature.

Authors:  Robert A Willinsky; Steve M Taylor; Karel TerBrugge; Richard I Farb; George Tomlinson; Walter Montanera
Journal:  Radiology       Date:  2003-03-13       Impact factor: 11.105

9.  Cerebral dural arteriovenous fistulas: clinical and angiographic correlation with a revised classification of venous drainage.

Authors:  C Cognard; Y P Gobin; L Pierot; A L Bailly; E Houdart; A Casasco; J Chiras; J J Merland
Journal:  Radiology       Date:  1995-03       Impact factor: 11.105

10.  The value of cerebral CT angiography with low tube voltage in detection of intracranial aneurysms.

Authors:  Kun Tang; Rui Li; Jie Lin; Xiangwu Zheng; Ling Wang; Weiwei Yin
Journal:  Biomed Res Int       Date:  2015-02-01       Impact factor: 3.411

View more
  10 in total

1.  Role of time-resolved-CTA in intracranial arteriovenous malformation evaluation at 128-slice CT in comparison with digital subtraction angiography.

Authors:  Rupinder Singh; Vivek Gupta; Chirag Ahuja; Ajay Kumar; Kanchan K Mukherjee; Niranjan Khandelwal
Journal:  Neuroradiol J       Date:  2018-01-25

Review 2.  Targeted endovascular treatment for ruptured brain arteriovenous malformations.

Authors:  Kun Hou; Kan Xu; Xuan Chen; Tiefeng Ji; Yunbao Guo; Jinlu Yu
Journal:  Neurosurg Rev       Date:  2019-11-13       Impact factor: 3.042

3.  Diagnostic value of four-dimensional CT angiography in arterial erectile dysfunction using 320-detector row dynamic volume CT.

Authors:  Cheng-Cheng Xu; Xin-Zhong Ruan; Yi-Fan Tang; Jiao-Hai Pan; Guo-Yao Wang; Qiu-Li Huang
Journal:  Biosci Rep       Date:  2017-08-21       Impact factor: 3.840

Review 4.  Imaging of Intracranial Hemorrhage.

Authors:  Jeremy J Heit; Michael Iv; Max Wintermark
Journal:  J Stroke       Date:  2016-12-12       Impact factor: 6.967

5.  High sensitivity and specificity of 4D-CTA in the detection of cranial arteriovenous shunts.

Authors:  Matthijs In 't Veld; Rolf Fronczek; Marlise P Dos Santos; Marianne A A van Walderveen; Frederick J A Meijer; Peter W A Willems
Journal:  Eur Radiol       Date:  2019-05-14       Impact factor: 5.315

6.  Dilated MMA sign in cDAVF and other arterial feeders on 3D TOF MRA.

Authors:  Sin Y Foo; Saravana K Swaminathan; Timo Krings
Journal:  Neuroradiol J       Date:  2021-08-27

7.  Feasibility of Metal Artifact Reduction on CT Angiography for Planning Direct Surgery of Tentorial dAVF after Onyx Embolization.

Authors:  Kanji Nakagawa; Shingo Toyota; Takeshi Shimizu; Tomoaki Murakami; Takuyu Taki
Journal:  Asian J Neurosurg       Date:  2022-08-25

8.  CT and DSA for evaluation of spontaneous intracerebral lobar bleedings.

Authors:  Jens-Christian Altenbernd; Sebastian Fischer; Wolfram Scharbrodt; Sebastian Schimrigk; Jens Eyding; Hannes Nordmeyer; Christine Wohlert; Nils Dörner; Yan Li; Karsten Wrede; Daniela Pierscianek; Martin Köhrmann; Benedikt Frank; Michael Forsting; Cornelius Deuschl
Journal:  Front Neurol       Date:  2022-10-03       Impact factor: 4.086

9.  Orbital arteriovenous fistula presenting with choroidal pulsations on optical coherence tomography.

Authors:  Akshay S Thomas; S Tammy Hsu; Lejla Vajzovic
Journal:  Am J Ophthalmol Case Rep       Date:  2018-08-19

Review 10.  Is four-dimensional CT angiography as effective as digital subtraction angiography in the detection of the underlying causes of intracerebral haemorrhage: a systematic review.

Authors:  C E Denby; K Chatterjee; R Pullicino; S Lane; M R Radon; K V Das
Journal:  Neuroradiology       Date:  2020-01-04       Impact factor: 2.804

  10 in total