| Literature DB >> 24325935 |
Giampietro Farronato1, Lucia Giannini, Guido Galbiati, Elena Grillo, Cinzia Maspero.
Abstract
BACKGROUND: The aim of the present study was to assess the muscular variations at the electromyography (EMG) level for the anterior temporalis muscles and masseter muscles during treatment with Occlus-o-Guide® and Andresen activator appliances.Entities:
Mesh:
Year: 2013 PMID: 24325935 PMCID: PMC3847849 DOI: 10.1186/2196-1042-14-4
Source DB: PubMed Journal: Prog Orthod ISSN: 1723-7785 Impact factor: 2.750
Figure 1Intraoral frontal view of a patient wearing an Occlus-o-Guide® appliance
Figure 2Intraoral frontal view of a patient wearing an Andresen activator.
EMG clench measures while not wearing the appliances
| POC-ATM (%) | Occlus-o-Guide® | 87 ± 5 | 87 ± 3 | 87 ± 4 |
| Andresen activator | 89 ± 2 | 87 ± 7 | 88 ± 5 | |
| 0.16 | 0.82 | 0.05 | ||
| POC-MM (%) | Occlus-o-Guide® | 86 ± 5 | 86 ± 6 | 88 ± 4 |
| Andresen activator | 88 ± 3 | 85 ± 6 | 88 ± 3 | |
| 0.19 | 0.68 | 0.88 | ||
| %RATM | Occlus-o-Guide® | 112 ± 27 | 105 ± 22 | 101 ± 24 |
| Andresen activator | 112 ± 30 | 108 ± 21 | 108 ± 28 | |
| 0.85 | 0.09 | 0.13 | ||
| %LATM | Occlus-o-Guide® | 113 ± 24 | 109 ± 24 | 107 ± 22 |
| Andresen activator | 112 ± 25 | 116 ± 23 | 108 ± 28 | |
| 0.71 | 0.18 | 0.90 | ||
| %RMM | Occlus-o-Guide® | 102 ± 27 | 101 ± 25 | 102 ± 18 |
| Andresen activator | 111 ± 34 | 112 ± 24 | 109 ± 25 | |
| 0.53 | 0.01 | 0.15 | ||
| %LMM | Occlus-o-Guide® | 105 ± 27 | 104 ± 30 | 104 ± 21 |
| Andresen activator | 111 ± 24 | 115 ± 36 | 109 ± 30 | |
| 0.30 | 0.15 | 0.97 | ||
Data are means ± standard deviation. T0, first use; T1, after 6 months; T2, after 12 months; POC-ATM, percent overlapping coefficient of the anterior temporalis muscles; POC-MM, percent overlapping coefficient of the masseter muscles; %RATM, %LATM, %RMM, %LMM, clench percentages for each muscle; p, significance between appliances (Mann–Whitney test).
EMG clench measures while wearing the appliances
| POC-ATM (%) | Occlus-o-Guide® | 79 ± 13 | 82 ± 7 | 83 ± 4 |
| Andresen activator | 73 ± 17 | 81 ± 10 | 82 ± 16 | |
| 0.25 | 0.72 | 0.09 | ||
| POC-MM (%) | Occlus-o-Guide® | 84 ± 8 | 85 ± 7 | 86 ± 4 |
| Andresen activator | 80 ± 8 | 84 ± 6 | 84 ± 12 | |
| 0.02 | 0.05 | 0.11 | ||
| %RATM | Occlus-o-Guide® | 60 ± 29 | 64 ± 19 | 68 ± 23 |
| Andresen activator | 46 ± 27 | 68 ± 36 | 88 ± 37 | |
| 0.05 | 0.96 | 0.001 | ||
| %LATM | Occlus-o-Guide® | 66 ± 39 | 65 ± 18 | 71 ± 26 |
| Andresen activator | 52 ± 28 | 58 ± 26 | 86 ± 24 | |
| 0.10 | 0.04 | 0.009 | ||
| %RMM | Occlus-o-Guide® | 87 ± 36 | 89 ± 26 | 99 ± 36 |
| Andresen activator | 60 ± 30 | 90 ± 32 | 99 ± 29 | |
| 0.001 | 0.92 | 0.40 | ||
| %LMM | Occlus-o-Guide® | 85 ± 43 | 88 ± 24 | 95 ± 31 |
| Andresen activator | 60 ± 30 | 87 ± 29 | 98 ± 32 | |
| 0.005 | 0.77 | 0.16 | ||
Data are means ± standard deviation. T0, first use; T1, after 6 months; T2, 12 after months; POC-ATM, percent overlapping coefficient of the anterior temporalis muscles; POC-MM, percent overlapping coefficient of the masseter muscles; %RATM, %LATM, %RMM, %LMM, clench percentages for each muscle; p, significance between appliances (Mann–Whitney test).