Literature DB >> 24323332

Liver fat quantification using a multi-step adaptive fitting approach with multi-echo GRE imaging.

Xiaodong Zhong1, Marcel D Nickel, Stephan A R Kannengiesser, Brian M Dale, Berthold Kiefer, Mustafa R Bashir.   

Abstract

PURPOSE: The purpose of this study was to develop a multi-step adaptive fitting approach for liver proton density fat fraction (PDFF) and R(2)* quantification, and to perform an initial validation on a broadly available hardware platform. THEORY AND METHODS: The proposed method uses a multi-echo three-dimensional gradient echo acquisition, with initial guesses for the fat and water signal fractions based on a Dixon decomposition of two selected echoes. Based on magnitude signal equations with a multi-peak fat spectral model, a multi-step nonlinear fitting procedure is then performed to adaptively update the fat and water signal fractions and R(2)* values. The proposed method was validated using numeric phantoms as ground truth, followed by preliminary clinical validation of PDFF calculations against spectroscopy in 30 patients.
RESULTS: The results of the proposed method agreed well with the ground truth of numerical phantoms, and were relatively insensitive to changes in field strength, field homogeneity, monopolar/bipolar readout, signal to noise ratio, and echo time selections. The in vivo patient study showed excellent consistency between the PDFF values measured with the proposed approach compared with spectroscopy.
CONCLUSION: This multi-step adaptive fitting approach performed well in both simulated and initial clinical evaluation, and shows potential in the quantification of hepatic steatosis.
Copyright © 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  Dixon; fat quantification; iron quantification; liver; water fat separation

Mesh:

Year:  2013        PMID: 24323332     DOI: 10.1002/mrm.25054

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  64 in total

1.  Quantification of early fatty infiltration of the rotator cuff muscles: comparison of multi-echo Dixon with single-voxel MR spectroscopy.

Authors:  Christoph A Agten; Andrea B Rosskopf; Christian Gerber; Christian W A Pfirrmann
Journal:  Eur Radiol       Date:  2015-12-17       Impact factor: 5.315

2.  Hepatic fat quantification using the proton density fat fraction (PDFF): utility of free-drawn-PDFF with a large coverage area.

Authors:  Kun Young Kim; Ji Soo Song; Stephan Kannengiesser; Young Min Han
Journal:  Radiol Med       Date:  2015-05-08       Impact factor: 3.469

3.  Validation of Peripheral Quantitative Computed Tomography-Derived Thigh Adipose Tissue Subcompartments in Young Girls Using a 3 T MRI Scanner.

Authors:  Robert M Blew; Vinson R Lee; Jennifer W Bea; Megan C Hetherington-Rauth; Jean-Phillipe Galons; Maria I Altbach; Timothy G Lohman; Scott B Going
Journal:  J Clin Densitom       Date:  2018-03-23       Impact factor: 2.617

4.  Sensitivity of chemical shift-encoded fat quantification to calibration of fat MR spectrum.

Authors:  Xiaoke Wang; Diego Hernando; Scott B Reeder
Journal:  Magn Reson Med       Date:  2015-04-04       Impact factor: 4.668

5.  Automated two-point dixon screening for the evaluation of hepatic steatosis and siderosis: comparison with R2-relaxometry and chemical shift-based sequences.

Authors:  B Henninger; H Zoller; S Rauch; M Schocke; S Kannengiesser; X Zhong; G Reiter; W Jaschke; C Kremser
Journal:  Eur Radiol       Date:  2014-12-14       Impact factor: 5.315

Review 6.  [CT and MRI of the liver: when, what, why?]

Authors:  J Budjan; S O Schoenberg; U I Attenberger
Journal:  Radiologe       Date:  2017-05       Impact factor: 0.635

7.  Free-breathing quantification of hepatic fat in healthy children and children with nonalcoholic fatty liver disease using a multi-echo 3-D stack-of-radial MRI technique.

Authors:  Tess Armstrong; Karrie V Ly; Smruthi Murthy; Shahnaz Ghahremani; Grace Hyun J Kim; Kara L Calkins; Holden H Wu
Journal:  Pediatr Radiol       Date:  2018-05-04

8.  A randomized, placebo-controlled trial of diindolylmethane for breast cancer biomarker modulation in patients taking tamoxifen.

Authors:  Cynthia A Thomson; H H Sherry Chow; Betsy C Wertheim; Denise J Roe; Alison Stopeck; Gertraud Maskarinec; Maria Altbach; Pavani Chalasani; Chuan Huang; Meghan B Strom; Jean-Philippe Galons; Patricia A Thompson
Journal:  Breast Cancer Res Treat       Date:  2017-05-30       Impact factor: 4.872

9.  Chemical Shift magnetization transfer magnetic resonance imaging.

Authors:  Weiguo Li; Xifu Wang; Frank H Miller; Andrew C Larson
Journal:  Magn Reson Med       Date:  2016-08-31       Impact factor: 4.668

10.  Effect of microscopic susceptibility gradients on chemical-shift-based fat fraction quantification in supraclavicular fat.

Authors:  Drew McCallister; Le Zhang; Alex Burant; Laurence Katz; Rosa Tamara Branca
Journal:  J Magn Reson Imaging       Date:  2018-10-04       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.