First full-beam PET acquisitions in proton therapy with a modular dual-head dedicated system.

G Sportelli1, N Belcari, N Camarlinghi, G A P Cirrone, G Cuttone, S Ferretti, A Kraan, J E Ortuño, F Romano, A Santos, K Straub, A Tramontana, A Del Guerra, V Rosso.   

Abstract

During particle therapy irradiation, positron emitters with half-lives ranging from 2 to 20 min are generated from nuclear processes. The half-lives are such that it is possible either to detect the positron signal in the treatment room using an in-beam positron emission tomography (PET) system, right after the irradiation, or to quickly transfer the patient to a close PET/CT scanner. Since the activity distribution is spatially correlated with the dose, it is possible to use PET imaging as an indirect method to assure the quality of the dose delivery. In this work, we present a new dedicated PET system able to operate in-beam. The PET apparatus consists in two 10 cm × 10 cm detector heads. Each detector is composed of four scintillating matrices of 23 × 23 LYSO crystals. The crystal size is 1.9 mm × 1.9 mm × 16 mm. Each scintillation matrix is read out independently with a modularized acquisition system. The distance between the two opposing detector heads was set to 20 cm. The system has very low dead time per detector area and a 3 ns coincidence window, which is capable to sustain high single count rates and to keep the random counts relatively low. This allows a new full-beam monitoring modality that includes data acquisition also while the beam is on. The PET system was tested during the irradiation at the CATANA (INFN, Catania, Italy) cyclotron-based proton therapy facility. Four acquisitions with different doses and dose rates were analysed. In all cases the random to total coincidences ratio was equal or less than 25%. For each measurement we estimated the accuracy and precision of the activity range on a set of voxel lines within an irradiated PMMA phantom. Results show that the inclusion of data acquired during the irradiation, referred to as beam-on data, improves both the precision and accuracy of the range measurement with respect to data acquired only after irradiation. Beam-on data alone are enough to give precisions better than 1 mm when at least 5 Gy are delivered.

Entities:  

Mesh:

Year:  2013        PMID: 24321855     DOI: 10.1088/0031-9155/59/1/43

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  9 in total

Review 1.  Innovations in Instrumentation for Positron Emission Tomography.

Authors:  Eric Berg; Simon R Cherry
Journal:  Semin Nucl Med       Date:  2018-03-12       Impact factor: 4.446

2.  INSIDE in-beam positron emission tomography system for particle range monitoring in hadrontherapy.

Authors:  Maria Giuseppina Bisogni; Andrea Attili; Giuseppe Battistoni; Nicola Belcari; Niccolo' Camarlinghi; Piergiorgio Cerello; Silvia Coli; Alberto Del Guerra; Alfredo Ferrari; Veronica Ferrero; Elisa Fiorina; Giuseppe Giraudo; Eleftheria Kostara; Matteo Morrocchi; Francesco Pennazio; Cristiana Peroni; Maria Antonietta Piliero; Giovanni Pirrone; Angelo Rivetti; Manuel D Rolo; Valeria Rosso; Paola Sala; Giancarlo Sportelli; Richard Wheadon
Journal:  J Med Imaging (Bellingham)       Date:  2016-12-02

Review 3.  In vivo range verification in particle therapy.

Authors:  Katia Parodi; Jerimy C Polf
Journal:  Med Phys       Date:  2018-11       Impact factor: 4.071

Review 4.  Latest developments in in-vivo imaging for proton therapy.

Authors:  Katia Parodi
Journal:  Br J Radiol       Date:  2019-12-12       Impact factor: 3.039

5.  Modelling the transport of optical photons in scintillation detectors for diagnostic and radiotherapy imaging.

Authors:  Emilie Roncali; Mohammad Amin Mosleh-Shirazi; Aldo Badano
Journal:  Phys Med Biol       Date:  2017-10-04       Impact factor: 3.609

6.  Online proton therapy monitoring: clinical test of a Silicon-photodetector-based in-beam PET.

Authors:  Veronica Ferrero; Elisa Fiorina; Matteo Morrocchi; Francesco Pennazio; Guido Baroni; Giuseppe Battistoni; Nicola Belcari; Niccolo' Camarlinghi; Mario Ciocca; Alberto Del Guerra; Marco Donetti; Simona Giordanengo; Giuseppe Giraudo; Vincenzo Patera; Cristiana Peroni; Angelo Rivetti; Manuel Dionisio da Rocha Rolo; Sandro Rossi; Valeria Rosso; Giancarlo Sportelli; Sara Tampellini; Francesca Valvo; Richard Wheadon; Piergiorgio Cerello; Maria Giuseppina Bisogni
Journal:  Sci Rep       Date:  2018-03-06       Impact factor: 4.379

7.  Localization of anatomical changes in patients during proton therapy with in-beam PET monitoring: A voxel-based morphometry approach exploiting Monte Carlo simulations.

Authors:  Aafke Christine Kraan; Andrea Berti; Alessandra Retico; Guido Baroni; Giuseppe Battistoni; Nicola Belcari; Piergiorgio Cerello; Mario Ciocca; Micol De Simoni; Damiano Del Sarto; Marco Donetti; Yunsheng Dong; Alessia Embriaco; Veronica Ferrero; Elisa Fiorina; Marta Fischetti; Gaia Franciosini; Giuseppe Giraudo; Francesco Laruina; Davide Maestri; Marco Magi; Giuseppe Magro; Carlo Mancini Terracciano; Michela Marafini; Ilaria Mattei; Enrico Mazzoni; Paolo Mereu; Riccardo Mirabelli; Alfredo Mirandola; Matteo Morrocchi; Silvia Muraro; Alessandra Patera; Vincenzo Patera; Francesco Pennazio; Angelo Rivetti; Manuel Dionisio Da Rocha Rolo; Valeria Rosso; Alessio Sarti; Angelo Schiavi; Adalberto Sciubba; Elena Solfaroli Camillocci; Giancarlo Sportelli; Sara Tampellini; Marco Toppi; Giacomo Traini; Serena Marta Valle; Francesca Valvo; Barbara Vischioni; Viviana Vitolo; Richard Wheadon; Maria Giuseppina Bisogni
Journal:  Med Phys       Date:  2021-12-22       Impact factor: 4.506

Review 8.  Range Verification Methods in Particle Therapy: Underlying Physics and Monte Carlo Modeling.

Authors:  Aafke Christine Kraan
Journal:  Front Oncol       Date:  2015-07-07       Impact factor: 6.244

9.  New Digital Plug and Imaging Sensor for a Proton Therapy Monitoring System Based on Positron Emission Tomography.

Authors:  Nicola D'Ascenzo; Min Gao; Emanuele Antonecchia; Paolo Gnudi; Hsien-Hsin Chen; Fang-Hsin Chen; Ji-Hong Hong; Ing-Tsung Hsiao; Tzu-Chen Yen; Weidong Wang; Daoming Xi; Bo Zhang; Qingguo Xie
Journal:  Sensors (Basel)       Date:  2018-09-08       Impact factor: 3.576

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.