Literature DB >> 24321758

Liquid chromatography and ion trap mass spectrometry for simultaneous and multiclass analysis of antimicrobial residues in feed water.

Chusak Ardsoongnearn1, Ongart Boonbanlu1, Sunan Kittijaruwattana1, Leena Suntornsuk2.   

Abstract

This work firstly reported the development of liquid chromatography coupled to an ion trap mass spectrometer (LC-MS ion trap) for the simultaneous determination of nitrofurans (e.g. nitrofurazone (NFZ), nitrofurantoin (NFT), furazolidone (FZD) and furaltadone (FTD)), nitroimidazoles (e.g. metronidazole (MNZ), ronidazole (RNZ) and dimetridazole (DMZ)) and chloramphenicol (CAP) in feed water. Isotope-labeled internal standards for the corresponding target analytes were employed to prevent matrix effects that might lead to signal suppression/enhancement. High performance liquid chromatography (HPLC) analysis was performed on a Prodigy ODS-3 column, 2.0mm×150mm, 5μm with a guard cartridge at a flow rate of 0.2mL/min, column oven temperature of 40°C, and an injection volume of 10μL. Solid phase extraction (SPE) procedures, factors affecting HPLC separation (e.g. buffer pH and concentrations) and mass spectrometry (MS) parameters were optimized. After an off-line SPE by the OASIS HLB cartridges (with an enrichment factor of 400), the eight antimicrobial agents were separated in 18min using a gradient elution of acetonitrile in acidified water (pH 5.0). MS detection was by an ion trap MS coupled with electrospray ionization (ESI) in tandem mass spectrometry mode (MS/MS) using the nebulizer gas at 35psi, drying gas at 9L/min and drying temperature of 325°C. Method linearity was good (r(2)=0.979-0.999) with acceptable precision (% RSDs=3.4-26.6%) and accuracy (%recovery=88.4-110.1%). Very low limits of detection (LOD) and quantitation (LOQ) were achieved in ranges of 0.002-0.06μg/L and 0.005-0.25μg/L, respectively. The established method is successfully employed by the Department of Livestock Development of Thailand for the monitoring of the drug residues in feed waterbecause of its convenience, reliability and high sensitivity.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Chloramphenicol; Feed water; HPLC-MS; Nitrofurans; Nitroimidazoles

Mesh:

Substances:

Year:  2013        PMID: 24321758     DOI: 10.1016/j.jchromb.2013.11.034

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  1 in total

1.  New Method of Analysis of Nitrofurans and Nitrofuran Metabolites in Different Biological Matrices Using UHPLC-MS/MS.

Authors:  Tomasz Śniegocki; Marta Giergiel; Bartosz Sell; Andrzej Posyniak
Journal:  J Vet Res       Date:  2018-10-24       Impact factor: 1.744

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.