Literature DB >> 24320527

High quality machine-robust image features: identification in nonsmall cell lung cancer computed tomography images.

Luke A Hunter1, Shane Krafft, Francesco Stingo, Haesun Choi, Mary K Martel, Stephen F Kry, Laurence E Court.   

Abstract

PURPOSE: For nonsmall cell lung cancer (NSCLC) patients, quantitative image features extracted from computed tomography (CT) images can be used to improve tumor diagnosis, staging, and response assessment. For these findings to be clinically applied, image features need to have high intra and intermachine reproducibility. The objective of this study is to identify CT image features that are reproducible, nonredundant, and informative across multiple machines.
METHODS: Noncontrast-enhanced, test-retest CT image pairs were obtained from 56 NSCLC patients imaged on three CT machines from two institutions. Two machines ("M1" and "M2") used cine 4D-CT and one machine ("M3") used breath-hold helical 3D-CT. Gross tumor volumes (GTVs) were semiautonomously segmented then pruned by removing voxels with CT numbers less than a prescribed Hounsfield unit (HU) cutoff. Three hundred and twenty eight quantitative image features were extracted from each pruned GTV based on its geometry, intensity histogram, absolute gradient image, co-occurrence matrix, and run-length matrix. For each machine, features with concordance correlation coefficient values greater than 0.90 were considered reproducible. The Dice similarity coefficient (DSC) and the Jaccard index (JI) were used to quantify reproducible feature set agreement between machines. Multimachine reproducible feature sets were created by taking the intersection of individual machine reproducible feature sets. Redundant features were removed through hierarchical clustering based on the average correlation between features across multiple machines.
RESULTS: For all image types, GTV pruning was found to negatively affect reproducibility (reported results use no HU cutoff). The reproducible feature percentage was highest for average images (M1 = 90.5%, M2 = 94.5%, M1∩M2 = 86.3%), intermediate for end-exhale images (M1 = 75.0%, M2 = 71.0%, M1∩M2 = 52.1%), and lowest for breath-hold images (M3 = 61.0%). Between M1 and M2, the reproducible feature sets generated from end-exhale images were relatively machine-sensitive (DSC = 0.71, JI = 0.55), and the reproducible feature sets generated from average images were relatively machine-insensitive (DSC = 0.90, JI = 0.87). Histograms of feature pair correlation distances indicated that feature redundancy was machine-sensitive and image type sensitive. After hierarchical clustering, 38 features, 28 features, and 33 features were found to be reproducible and nonredundant for M1∩M2 (average images), M1∩M2 (end-exhale images), and M3, respectively. When blinded to the presence of test-retest images, hierarchical clustering showed that the selected features were informative by correctly pairing 55 out of 56 test-retest images using only their reproducible, nonredundant feature set values.
CONCLUSIONS: Image feature reproducibility and redundancy depended on both the CT machine and the CT image type. For each image type, the authors found a set of cross-machine reproducible, nonredundant, and informative image features that would be useful for future image-based models. Compared to end-exhale 4D-CT and breath-hold 3D-CT, average 4D-CT derived image features showed superior multimachine reproducibility and are the best candidates for clinical correlation.

Entities:  

Mesh:

Year:  2013        PMID: 24320527      PMCID: PMC4108720          DOI: 10.1118/1.4829514

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  23 in total

1.  New guidelines to evaluate the response to treatment in solid tumors. European Organization for Research and Treatment of Cancer, National Cancer Institute of the United States, National Cancer Institute of Canada.

Authors:  P Therasse; S G Arbuck; E A Eisenhauer; J Wanders; R S Kaplan; L Rubinstein; J Verweij; M Van Glabbeke; A T van Oosterom; M C Christian; S G Gwyther
Journal:  J Natl Cancer Inst       Date:  2000-02-02       Impact factor: 13.506

2.  Fractal analysis of small peripheral pulmonary nodules in thin-section CT: evaluation of the lung-nodule interfaces.

Authors:  Shoji Kido; Keiko Kuriyama; Masahiko Higashiyama; Tsutomu Kasugai; Chikazumi Kuroda
Journal:  J Comput Assist Tomogr       Date:  2002 Jul-Aug       Impact factor: 1.826

3.  Acquiring 4D thoracic CT scans using a multislice helical method.

Authors:  P J Keall; G Starkschall; H Shukla; K M Forster; V Ortiz; C W Stevens; S S Vedam; R George; T Guerrero; R Mohan
Journal:  Phys Med Biol       Date:  2004-05-21       Impact factor: 3.609

4.  Five-year lung cancer screening experience: CT appearance, growth rate, location, and histologic features of 61 lung cancers.

Authors:  Rebecca M Lindell; Thomas E Hartman; Stephen J Swensen; James R Jett; David E Midthun; Henry D Tazelaar; Jayawant N Mandrekar
Journal:  Radiology       Date:  2007-02       Impact factor: 11.105

5.  A concordance correlation coefficient to evaluate reproducibility.

Authors:  L I Lin
Journal:  Biometrics       Date:  1989-03       Impact factor: 2.571

6.  Non-small cell lung cancer: histopathologic correlates for texture parameters at CT.

Authors:  Balaji Ganeshan; Vicky Goh; Henry C Mandeville; Quan Sing Ng; Peter J Hoskin; Kenneth A Miles
Journal:  Radiology       Date:  2012-11-20       Impact factor: 11.105

7.  Use of a realistic breathing lung phantom to evaluate dose delivery errors.

Authors:  Laurence E Court; Joao Seco; Xing-Qi Lu; Kazuyu Ebe; Charles Mayo; Dan Ionascu; Brian Winey; Nikos Giakoumakis; Michalis Aristophanous; Ross Berbeco; Joerg Rottman; Madeleine Bogdanov; Deborah Schofield; Tania Lingos
Journal:  Med Phys       Date:  2010-11       Impact factor: 4.071

8.  Automated medical image segmentation techniques.

Authors:  Neeraj Sharma; Lalit M Aggarwal
Journal:  J Med Phys       Date:  2010-01

9.  Cluster analysis and display of genome-wide expression patterns.

Authors:  M B Eisen; P T Spellman; P O Brown; D Botstein
Journal:  Proc Natl Acad Sci U S A       Date:  1998-12-08       Impact factor: 11.205

10.  Texture analysis of aggressive and nonaggressive lung tumor CE CT images.

Authors:  Omar S Al-Kadi; D Watson
Journal:  IEEE Trans Biomed Eng       Date:  2008-07       Impact factor: 4.538

View more
  49 in total

1.  Short-term reproducibility of radiomic features in liver parenchyma and liver malignancies on contrast-enhanced CT imaging.

Authors:  Thomas Perrin; Abhishek Midya; Rikiya Yamashita; Jayasree Chakraborty; Tome Saidon; William R Jarnagin; Mithat Gonen; Amber L Simpson; Richard K G Do
Journal:  Abdom Radiol (NY)       Date:  2018-12

2.  Radiomics robustness assessment and classification evaluation: A two-stage method demonstrated on multivendor FFDM.

Authors:  Kayla Robinson; Hui Li; Li Lan; David Schacht; Maryellen Giger
Journal:  Med Phys       Date:  2019-03-12       Impact factor: 4.071

Review 3.  Towards precision medicine: from quantitative imaging to radiomics.

Authors:  U Rajendra Acharya; Yuki Hagiwara; Vidya K Sudarshan; Wai Yee Chan; Kwan Hoong Ng
Journal:  J Zhejiang Univ Sci B       Date:  2018 Jan.       Impact factor: 3.066

4.  Influence of segmentation margin on machine learning-based high-dimensional quantitative CT texture analysis: a reproducibility study on renal clear cell carcinomas.

Authors:  Burak Kocak; Ece Ates; Emine Sebnem Durmaz; Melis Baykara Ulusan; Ozgur Kilickesmez
Journal:  Eur Radiol       Date:  2019-02-12       Impact factor: 5.315

5.  Investigating the Robustness Neighborhood Gray Tone Difference Matrix and Gray Level Co-occurrence Matrix Radiomic Features on Clinical Computed Tomography Systems Using Anthropomorphic Phantoms: Evidence From a Multivendor Study.

Authors:  Usman Mahmood; Aditya P Apte; Joseph O Deasy; C Ross Schmidtlein; Amita Shukla-Dave
Journal:  J Comput Assist Tomogr       Date:  2017 Nov/Dec       Impact factor: 1.826

6.  IBEX: an open infrastructure software platform to facilitate collaborative work in radiomics.

Authors:  Lifei Zhang; David V Fried; Xenia J Fave; Luke A Hunter; Jinzhong Yang; Laurence E Court
Journal:  Med Phys       Date:  2015-03       Impact factor: 4.071

7.  Systematic analysis of bias and variability of texture measurements in computed tomography.

Authors:  Marthony Robins; Justin Solomon; Jocelyn Hoye; Ehsan Abadi; Daniele Marin; Ehsan Samei
Journal:  J Med Imaging (Bellingham)       Date:  2019-07-12

8.  STAN-CT: Standardizing CT Image using Generative Adversarial Networks.

Authors:  Md Selim; Jie Zhang; Baowei Fei; Guo-Qiang Zhang; Jin Chen
Journal:  AMIA Annu Symp Proc       Date:  2021-01-25

Review 9.  Clinical applications of textural analysis in non-small cell lung cancer.

Authors:  Iain Phillips; Mazhar Ajaz; Veni Ezhil; Vineet Prakash; Sheaka Alobaidli; Sarah J McQuaid; Christopher South; James Scuffham; Andrew Nisbet; Philip Evans
Journal:  Br J Radiol       Date:  2017-10-27       Impact factor: 3.039

10.  Uncertainty analysis of quantitative imaging features extracted from contrast-enhanced CT in lung tumors.

Authors:  Jinzhong Yang; Lifei Zhang; Xenia J Fave; David V Fried; Francesco C Stingo; Chaan S Ng; Laurence E Court
Journal:  Comput Med Imaging Graph       Date:  2015-12-14       Impact factor: 4.790

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.