Ex Vivo characterization of canine liver tissue viscoelasticity after high-intensity focused ultrasound ablation.

Danial Shahmirzadi1, Gary Y Hou1, Jiangang Chen1, Elisa E Konofagou2.   

Abstract

The potential of elasticity imaging to detect high-intensity focused ultrasound (HIFU) lesions on the basis of their distinct biomechanical properties is promising. However, information on the quantitative mechanical properties of the tissue and the optimal intensity at which to determine the best contrast parameters is scarce. In this study, fresh canine livers were ablated using combinations of ISPTA intensities of 5.55, 7.16 and 9.07 kW/cm(2) and durations of 10 and 30 s ex vivo, resulting in six groups of ablated tissues. Biopsy samples were then interrogated using dynamic shear mechanical testing within the range of 0.1-10 Hz to characterize the tissue's post-ablation viscoelastic properties. All mechanical parameters were found to be frequency dependent. Compared with unablated cases, all six groups of ablated tissues had statistically significant higher complex shear modulus and shear viscosity. However, among the ablated groups, both complex shear modulus and shear viscosity were found to monotonically increase in groups 1-4 (5.55 kW/cm(2) for 10 s, 7.16 kW/cm(2) for 10 s, 9.07 kW/cm(2) for 10 s, and 5.55 kW/cm(2) for 30 s, respectively), but to decrease in groups 5 and 6 (7.16 kW/cm(2) for 30 s, and 9.07 kW/cm(2) for 30 s, respectively). For groups 5 and 6, the temperature was expected to exceed the boiling point, and therefore, the decreased stiffening could be due to the compromised integrity of the tissue microstructure. Future studies will entail estimation tissue mechanical properties in vivo and perform real-time monitoring of tissue alterations during ablation.
Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Canine liver; Elasticity imaging; Harmonic motion imaging for focused ultrasound; High-intensity focused ultrasound; Thermal ablation; Viscoelasticity

Mesh:

Year:  2013        PMID: 24315395      PMCID: PMC4005882          DOI: 10.1016/j.ultrasmedbio.2013.09.016

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  68 in total

1.  Assessment of thermal tissue ablation with MR elastography.

Authors:  T Wu; J P Felmlee; J F Greenleaf; S J Riederer; R L Ehman
Journal:  Magn Reson Med       Date:  2001-01       Impact factor: 4.668

2.  Production of focal destructive lesions in the central nervous system with ultrasound.

Authors:  W J FRY; W H MOSBERG; J W BARNARD; F J FRY
Journal:  J Neurosurg       Date:  1954-09       Impact factor: 5.115

3.  Controlled tissue emulsification produced by high intensity focused ultrasound shock waves and millisecond boiling.

Authors:  Tatiana D Khokhlova; Michael S Canney; Vera A Khokhlova; Oleg A Sapozhnikov; Lawrence A Crum; Michael R Bailey
Journal:  J Acoust Soc Am       Date:  2011-11       Impact factor: 1.840

4.  Effects of acoustic parameters on bubble cloud dynamics in ultrasound tissue erosion (histotripsy).

Authors:  Zhen Xu; Timothy L Hall; J Brian Fowlkes; Charles A Cain
Journal:  J Acoust Soc Am       Date:  2007-07       Impact factor: 1.840

5.  Monitoring of thermal therapy based on shear modulus changes: II. Shear wave imaging of thermal lesions.

Authors:  Bastien Arnal; Mathieu Pernot; Mickael Tanter
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-08       Impact factor: 2.725

6.  Tissue response to mechanical vibrations for "sonoelasticity imaging".

Authors:  K J Parker; S R Huang; R A Musulin; R M Lerner
Journal:  Ultrasound Med Biol       Date:  1990       Impact factor: 2.998

7.  Ultrasound-stimulated vibro-acoustic spectrography.

Authors:  M Fatemi; J F Greenleaf
Journal:  Science       Date:  1998-04-03       Impact factor: 47.728

8.  Elastographic imaging of low-contrast elastic modulus distributions in tissue.

Authors:  F Kallel; J Ophir; K Magee; T Krouskop
Journal:  Ultrasound Med Biol       Date:  1998-03       Impact factor: 2.998

9.  Elastography: elasticity imaging using ultrasound with application to muscle and breast in vivo.

Authors:  I Céspedes; J Ophir; H Ponnekanti; N Maklad
Journal:  Ultrason Imaging       Date:  1993-04       Impact factor: 1.578

10.  High intensity focused ultrasound for the treatment of rat tumours.

Authors:  G ter Haar; I Rivens; L Chen; S Riddler
Journal:  Phys Med Biol       Date:  1991-11       Impact factor: 3.609

View more
  8 in total

1.  High intensity focused ultrasound as a tool for tissue engineering: Application to cartilage.

Authors:  Adam B Nover; Gary Y Hou; Yang Han; Shutao Wang; Grace D O'Connell; Gerard A Ateshian; Elisa E Konofagou; Clark T Hung
Journal:  Med Eng Phys       Date:  2015-12-24       Impact factor: 2.242

Review 2.  Thermometry and ablation monitoring with ultrasound.

Authors:  Matthew A Lewis; Robert M Staruch; Rajiv Chopra
Journal:  Int J Hyperthermia       Date:  2015-03-10       Impact factor: 3.914

Review 3.  Heating technology for malignant tumors: a review.

Authors:  H Petra Kok; Erik N K Cressman; Wim Ceelen; Christopher L Brace; Robert Ivkov; Holger Grüll; Gail Ter Haar; Peter Wust; Johannes Crezee
Journal:  Int J Hyperthermia       Date:  2020       Impact factor: 3.914

4.  Bubble-Induced Color Doppler Feedback for Histotripsy Tissue Fractionation.

Authors:  Ryan M Miller; Xi Zhang; Adam D Maxwell; Charles A Cain; Zhen Xu
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-02-04       Impact factor: 2.725

5.  High-intensity focused ultrasound monitoring using harmonic motion imaging for focused ultrasound (HMIFU) under boiling or slow denaturation conditions.

Authors:  Gary Y Hou; Fabrice Marquet; Shutao Wang; Iason-Zacharias Apostolakis; Elisa E Konofagou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-07       Impact factor: 2.725

6.  Multi-parametric monitoring and assessment of high-intensity focused ultrasound (HIFU) boiling by harmonic motion imaging for focused ultrasound (HMIFU): an ex vivo feasibility study.

Authors:  Gary Y Hou; Fabrice Marquet; Shutao Wang; Elisa E Konofagou
Journal:  Phys Med Biol       Date:  2014-02-20       Impact factor: 3.609

7.  Monitoring Radiofrequency Ablation Using Ultrasound Envelope Statistics and Shear Wave Elastography in the Periablation Period: An In Vitro Feasibility Study.

Authors:  Po-Hsiang Tsui; Chiao-Yin Wang; Zhuhuang Zhou; Yung-Liang Wan
Journal:  PLoS One       Date:  2016-09-07       Impact factor: 3.240

8.  Viscoelastic biomarker for differentiation of benign and malignant breast lesion in ultra- low frequency range.

Authors:  Alireza Nabavizadeh; Mahdi Bayat; Viksit Kumar; Adriana Gregory; Jeremy Webb; Azra Alizad; Mostafa Fatemi
Journal:  Sci Rep       Date:  2019-04-05       Impact factor: 4.379

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.