Assessment of thermal tissue ablation with MR elastography.

T Wu1, J P Felmlee, J F Greenleaf, S J Riederer, R L Ehman.   

Abstract

An important part of thermal ablation therapy is the assessment of the spatial extent of tissue coagulation. In this work, the mechanical properties of thermally-ablated tissue were quantitatively evaluated using magnetic resonance elastography (MRE). This study shows that the mechanical properties of focused ultrasound ablated tissue are significantly different from normal tissue, and the difference can be imaged and measured using MRE. Repeated experiments revealed a reproducible pattern of tissue mechanical property change during thermal ablation in ex vivo bovine muscle. This pattern may reflect changes in intrinsic tissue structure and could be used to evaluate tissue coagulation during thermal ablation therapy. Magn Reson Med 45:80-87, 2001. Copyright 2001 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2001        PMID: 11146489     DOI: 10.1002/1522-2594(200101)45:1<80::aid-mrm1012>3.0.co;2-y

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  47 in total

1.  Harmonic Motion Imaging (HMI) for Tumor Imaging and Treatment Monitoring.

Authors:  Elisa E Konofagou; Caroline Maleke; Jonathan Vappou
Journal:  Curr Med Imaging Rev       Date:  2012

2.  Electrode displacement strain imaging of thermally-ablated liver tissue in an in vivo animal model.

Authors:  N Rubert; S Bharat; R J DeWall; A Andreano; C Brace; J Jiang; L Sampson; T Varghese
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

3.  High intensity focused ultrasound as a tool for tissue engineering: Application to cartilage.

Authors:  Adam B Nover; Gary Y Hou; Yang Han; Shutao Wang; Grace D O'Connell; Gerard A Ateshian; Elisa E Konofagou; Clark T Hung
Journal:  Med Eng Phys       Date:  2015-12-24       Impact factor: 2.242

4.  Radio-frequency ablation electrode displacement elastography: a phantom study.

Authors:  Shyam Bharat; Tomy Varghese; Ernest L Madsen; James A Zagzebski
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

5.  Real-time sonoelastography of hepatic thermal lesions in a swine model.

Authors:  Man Zhang; Benjamin Castaneda; Jared Christensen; Wael E Saad; Kevin Bylund; Kenneth Hoyt; John G Strang; Deborah J Rubens; Kevin J Parker
Journal:  Med Phys       Date:  2008-09       Impact factor: 4.071

6.  Magnetic resonance acoustic radiation force imaging.

Authors:  Nathan McDannold; Stephan E Maier
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

7.  Three-dimensional electrode displacement elastography using the Siemens C7F2 fourSight four-dimensional ultrasound transducer.

Authors:  Shyam Bharat; Ted G Fisher; Tomy Varghese; Timothy J Hall; Jingfeng Jiang; Ernest L Madsen; James A Zagzebski; Fred T Lee
Journal:  Ultrasound Med Biol       Date:  2008-03-28       Impact factor: 2.998

8.  Multi-parametric monitoring and assessment of high-intensity focused ultrasound (HIFU) boiling by harmonic motion imaging for focused ultrasound (HMIFU): an ex vivo feasibility study.

Authors:  Gary Y Hou; Fabrice Marquet; Shutao Wang; Elisa E Konofagou
Journal:  Phys Med Biol       Date:  2014-02-20       Impact factor: 3.609

9.  MR-guided transcranial brain HIFU in small animal models.

Authors:  B Larrat; M Pernot; J-F Aubry; E Dervishi; R Sinkus; D Seilhean; Y Marie; A-L Boch; M Fink; M Tanter
Journal:  Phys Med Biol       Date:  2009-12-17       Impact factor: 3.609

10.  Preliminary analysis of ultrasound elastography imaging-based thermometry on non-perfused ex vivo swine liver.

Authors:  Francesco Giurazza; Carlo Massaroni; Sergio Silvestri; Bruno Beomonte Zobel; Emiliano Schena
Journal:  J Ultrasound       Date:  2019-09-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.