Literature DB >> 24314823

Regadenoson-stress myocardial CT perfusion and single-photon emission CT: rationale, design, and acquisition methods of a prospective, multicenter, multivendor comparison.

Ricardo C Cury1, Therese M Kitt2, Kathleen Feaheny3, Jamie Akin3, Richard T George4.   

Abstract

Pharmacologic stress myocardial CT perfusion (CTP) has been reported to be a viable imaging modality for detection of myocardial ischemia compared with single-photon emission CT (SPECT) in several single-center studies. However, regadenoson-stress CTP has not previously been compared with SPECT in a multicenter, multivendor study. The rationale and design of a phase 2, randomized, cross-over study of regadenoson-stress myocardial perfusion imaging by CTP compared with SPECT are described herein. The study will be conducted at approximately 25 sites by using 6 different CT scanner models, including 64-, 128-, 256-, and 320-slice systems. Subjects with known/suspected coronary artery disease will be randomly assigned to 1 of 2 imaging procedure sequences; rest and regadenoson-stress SPECT on day 1, then regadenoson-stress CTP and rest CTP/coronary CT angiography (same acquisition) on day 2; or regadenoson-stress CTP and rest CTP/CT angiography on day 1, then rest and regadenoson-stress SPECT on day 2. The prespecified primary analysis examines the agreement rate between CTP and SPECT for detecting or excluding ischemia (≥2 or 0-1 reversible defects, respectively), as assessed by 3 independent blinded readers for each modality. Non-inferiority will be indicated if the lower boundary of the 95% CI for the agreement rate is within 0.15 of 0.78 (the observed agreement rate in the regadenoson pivotal trials). The protocol described herein will support the first evaluation of regadenoson-stress CTP by using multiple scanner types compared with SPECT.
Copyright © 2014 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  CT perfusion imaging; Cardiovascular imaging; Pharmacologic stress; Regadenoson; Single-photon emission CT; Study design

Mesh:

Substances:

Year:  2013        PMID: 24314823     DOI: 10.1016/j.jcct.2013.09.004

Source DB:  PubMed          Journal:  J Cardiovasc Comput Tomogr        ISSN: 1876-861X


  4 in total

Review 1.  Noninvasive Imaging to Evaluate Women With Stable Ischemic Heart Disease.

Authors:  Lauren A Baldassarre; Subha V Raman; James K Min; Jennifer H Mieres; Martha Gulati; Nanette K Wenger; Thomas H Marwick; Chiara Bucciarelli-Ducci; C Noel Bairey Merz; Dipti Itchhaporia; Keith C Ferdinand; Carl J Pepine; Mary Norine Walsh; Jagat Narula; Leslee J Shaw
Journal:  JACC Cardiovasc Imaging       Date:  2016-04

2.  Combined coronary angiography and myocardial perfusion by computed tomography in the identification of flow-limiting stenosis - The CORE320 study: An integrated analysis of CT coronary angiography and myocardial perfusion.

Authors:  Tiago A Magalhães; Satoru Kishi; Richard T George; Armin Arbab-Zadeh; Andrea L Vavere; Christopher Cox; Matthew B Matheson; Julie M Miller; Jeffrey Brinker; Marcelo Di Carli; Frank J Rybicki; Carlos E Rochitte; Melvin E Clouse; João A C Lima
Journal:  J Cardiovasc Comput Tomogr       Date:  2015-03-21

Review 3.  Functional relevance of coronary artery disease by cardiac magnetic resonance and cardiac computed tomography: myocardial perfusion and fractional flow reserve.

Authors:  Gianluca Pontone; Daniele Andreini; Andrea Baggiano; Erika Bertella; Saima Mushtaq; Edoardo Conte; Virginia Beltrama; Andrea Igoren Guaricci; Mauro Pepi
Journal:  Biomed Res Int       Date:  2015-01-27       Impact factor: 3.411

4.  Regadenoson-Stress Dynamic Myocardial Perfusion Improves Diagnostic Performance of CT Angiography in Assessment of Intermediate Coronary Artery Stenosis in Asymptomatic Patients.

Authors:  Jan Baxa; Milan Hromádka; Jakub Šedivý; Lucie Štěpánková; Jiří Moláček; Bernhard Schmidt; Thomas Flohr; Jiří Ferda
Journal:  Biomed Res Int       Date:  2015-07-05       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.