A μElution solid-phase extraction (SPE) liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous determination of diazepam, nordiazepam, oxazepam, oxazepam glucuronide, temazepam and temazepam glucuronide in human whole blood is presented. 200 μL of whole blood samples were loaded onto a Waters Oasis HLB 96-well μElution SPE plate using 75 μL of methanol as the elution solvent, and the eluents were injected into an Eclipse XDB C18 column. No hydrolysis, solvent transfer, evaporation or reconstitution was involved in the sample preparation procedures. Tandem mass spectrometric detection with Turbo Ion Spray was conducted via multiple reaction monitoring (MRM) under positive ionization mode. The method was validated and proved to be accurate (accuracy within 93-108%), precise (intra-day RSD<9.9% and inter-day RSD<7.2%) and sensitive with limits of detection (LOD) in the range of 0.05-0.25 ng/mL for all the compounds. Extraction recoveries were in the range of 31-80% for all the analytes. This method demonstrated to be reproducible and reliable. The applicability of the method was demonstrated by analysis of several forensic cases involving diazepam and its metabolites.
Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  96-Well μElution plate solid-phase extraction; Diazepam; Diazepam glucuronides; Human whole blood; LC–MS/MS

Mesh:

Substances:

Year:  2013        PMID: 24314534     DOI: 10.1016/j.forsciint.2013.10.004

Source DB:  PubMed          Journal:  Forensic Sci Int        ISSN: 0379-0738            Impact factor:   2.395


  4 in total

1.  Deposition of diazepam and its metabolites in hair following a single dose of diazepam.

Authors:  Xin Wang; Sys Stybe Johansen; Yurong Zhang; Jingying Jia; Yulan Rao; Fengli Jiang; Kristian Linnet
Journal:  Int J Legal Med       Date:  2016-08-17       Impact factor: 2.686

2.  A high-throughput bioanalytical assay to support pharmacokinetic interaction study of oxycodone and diazepam in Sprague Dawley rats.

Authors:  Nageswara R Pilli; Suresh Narayanasamy; Lin Xu; Ashok Chockalingam; Katherine I Shea; Sharron Stewart; Rodney Rouse; Vikram Patel; Murali K Matta
Journal:  RSC Adv       Date:  2020-01-03       Impact factor: 4.036

3.  Development of a Flow Injection System for Differential Pulse Amperometry and Its Application for Diazepam Determination.

Authors:  Vesna Antunović; Slavna Tešanović; Danica Perušković; Nikola Stevanović; Rada Baošić; Snežana Mandić; Aleksandar Lolić
Journal:  J Anal Methods Chem       Date:  2018-03-19       Impact factor: 2.193

4.  Development of a simple and sensitive HPLC-MS/MS method for determination of diazepam in human plasma and its application to a bioequivalence study.

Authors:  Do-Hyung Kim; Ji-Yoon Cho; Soo-In Chae; Bo-Kyung Kang; Tae-Gil An; Wang-Seob Shim; Young Su Noh; Se Jung Hwang; Eun Kyoung Chung; Kyung-Tae Lee
Journal:  Transl Clin Pharmacol       Date:  2017-12-20
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.