Literature DB >> 24312720

Performance characteristics of a new flexible nitinol 19-gauge endoscopic ultrasound-guided fine needle aspiration needle.

Disaya Chavalitdhamrong1, Peter V Draganov.   

Abstract

Entities:  

Mesh:

Year:  2013        PMID: 24312720      PMCID: PMC3848537          DOI: 10.5009/gnl.2013.7.6.756

Source DB:  PubMed          Journal:  Gut Liver        ISSN: 1976-2283            Impact factor:   4.519


× No keyword cloud information.
We would like to report out results with the use of new flexible nitinol 19 gauge (G) endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) needle. We studied the performance characteristics of this new EUS needle (Expect™ 19 Flex; Boston Scientific, Natick, MA, USA) in cases considered difficult to perform with traditional stainless steel 19 G needles. Inclusion criteria were 1) lesion in the pancreatic head, 2) nondiagnostic prior EUS-FNA, 3) subepithelial lesion in proximal stomach, and 4) passage of 0.035" wire needed to facilitate EUS-guided therapeutic procedure. Ten EUS procedures were done in 10 patients. We experienced technical success in all patients (100%). Adequate for cytologic evaluation specimen was obtained by mean of 1.2 (range, 1 to 2) passes in all eight patients (100%: six pancreatic head mass, one prior nondiagnostic EUS-FNA, and one gastric subepithelial lesion). One pseudocyst drainage and one pancreatic duct drainage were both successful. In one patient we were unable to achieve the final diagnosis despite the adequate specimen for evaluation by our cytologist. Of the seven cases in which final tissue diagnosis was achieved, FNA established the diagnosis in five (71%), and the remaining two required surgical biopsy. For all patients, the diagnostic yield of FNA was five out of eight (63%). Performance characteristics needle scores (1, best; 3, same; 5, worst compare with stainless steel 19 G needle) were passability through the scope 1.67±0.5, sharpness 1.55±0.53, visualization 2.22±0.44, durability 2.33±0.71, connection to the scope 2.44±0.73, ergonomics 2.44±0.53, and overall performance 1.89±0.33. There were no complications. In summary, our findings further expand on the data reported by Varadarajulu et al.1 We demonstrate that in cases considered difficult to perform with traditional stainless steel 19 G needles, the new flexible 19 G nitinol EUS needle provides high procedure success rate. In most cases requiring tissue sampling, cytologic diagnosis was achieved with a single needle pass. Performance characteristics of the new flexible needle were superior to the traditional 19 G needles, but the diagnostic yield remained the same. The limitations of our study are the subjectively-rated needle performance characteristics by one endoscopist and a small sample size. Further studies are required to better validate these findings and evaluate the new needle's abilities to obtain histologic samples.
  1 in total

1.  Assessment of the technical performance of the flexible 19-gauge EUS-FNA needle.

Authors:  Shyam Varadarajulu; Ji Young Bang; Shantel Hebert-Magee
Journal:  Gastrointest Endosc       Date:  2012-08       Impact factor: 9.427

  1 in total
  2 in total

1.  Interventional EUS Using a Flexible 19-Gauge Needle: An International Multicenter Experience in 162 Patients.

Authors:  Vivek Kumbhari; Irene Peñas; Alan H Tieu; Carlos De la Serna-Higuera; Manie Juneja; Fuad Maufa; Saowanee Ngamruengphong; Mohamad H El-Zein; Nadim Haddad; Sandeep Krishnan; Susana Gonzalez; Peter V Renny; Payal Saxena; Linda Howard; Christopher J DiMaio; Jonathan M Buscaglia; Manuel Perez-Miranda; Mouen A Khashab
Journal:  Dig Dis Sci       Date:  2016-10-06       Impact factor: 3.199

2.  Multicenter, randomized comparison of the diagnostic accuracy of 19-gauge stainless steel and nitinol-based needles for endoscopic ultrasound-guided fine-needle biopsy of solid pancreatic masses.

Authors:  Alexander Hann; Sonja Epp; Lothar Veits; Ulrich Rosien; Julian Siegel; Oliver Möschler; Wolfram Bohle; Alexander Meining
Journal:  United European Gastroenterol J       Date:  2019-11-07       Impact factor: 4.623