Literature DB >> 24311473

Ultrasound estimation of birth weight in twin pregnancy: comparison of biometry algorithms in the STORK multiple pregnancy cohort.

A Khalil1, F D'Antonio, T Dias, D Cooper, B Thilaganathan.   

Abstract

OBJECTIVES: The aims of this study were first, to ascertain the accuracy of formulae for ultrasonographic birth-weight estimation in twin compared with singleton pregnancies and second, to assess the accuracy of sonographic examination in the prediction of birth-weight discordance in twin pregnancies.
METHODS: This was a retrospective cohort study including both singleton and twin pregnancies. Routine biometry was recorded and estimated fetal weight (EFW) calculated using 33 different formulae. Only pregnancies that delivered within 48 h of the ultrasound scan were included (4280 singleton and 586 twin fetuses). Differences between the EFW and actual birth weight (ABW) were assessed by percentage error, accuracy in predictions within ± 10% and ± 15% of error and use of the Bland-Altman method. The accuracy of prediction of the different cut-offs of birth-weight discordance in twin pregnancies was also assessed using the area under the receiver-operating characteristics curve (AUC).
RESULTS: The overall mean absolute percentage error was ≤ 10% for 25 formulae in singleton pregnancies compared with three formulae in twin pregnancies. The overall predictions within ± 10% and ± 15% of the ABW were 62.2% and 81.5% in singleton and 49.7% and 68.5% in twin pregnancies, respectively. When t e formulae were categorized according to the biometric parameters included, those based on a combination of head, abdomen and femur measurements showed the lowest mean absolute percentage error, in both singleton and twin pregnancies. The predictive accuracy for 25% birth-weight discordance using the Hadlock 2 formula, as assessed by the AUC, was 0.87.
CONCLUSIONS: Ultrasound estimation of birth weight is less accurate in twin than in singleton pregnancies. Formulae that include a combination of head, abdomen and femur measurements perform best in both singleton and twin pregnancies.
Copyright © 2013 ISUOG. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  algorithms; biometry; birth weight; formula; twin pregnancy; ultrasound

Mesh:

Year:  2014        PMID: 24311473     DOI: 10.1002/uog.13253

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  4 in total

Review 1.  Ultrasound surveillance in twin pregnancy: An update for practitioners.

Authors:  R Townsend; A Khalil
Journal:  Ultrasound       Date:  2018-08-22

2.  The accuracy of ultrasound estimation of fetal weight in comparison to birth weight: A systematic review.

Authors:  Julia Milner; Jane Arezina
Journal:  Ultrasound       Date:  2018-02-07

3.  Predictive value of prenatal ultrasound parameters for dichorionic growth discordant twins.

Authors:  Ting Yuan; Chao Li; Yan Yan Wang; Wei Wang; Xue Lan Li; Fen Li; Zhen Han
Journal:  BMC Pregnancy Childbirth       Date:  2020-07-29       Impact factor: 3.007

4.  The accuracy of prenatal diagnosis of selective fetal growth restriction with second trimester Doppler ultrasound in monochorionic diamniotic twin pregnancies.

Authors:  Yao Wang; Ai Zhang; Tineck Stock; Enrico Lopriore; Dick Oepkes; Qiuzhen Wang
Journal:  PLoS One       Date:  2021-08-09       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.