Literature DB >> 24301987

Highly-Integrated CMOS Interface Circuits for SiPM-Based PET Imaging Systems.

Samrat Dey1, Thomas K Lewellen, Robert S Miyaoka, Jacques C Rudell.   

Abstract

Recent developments in the area of Positron Emission Tomography (PET) detectors using Silicon Photomultipliers (SiPMs) have demonstrated the feasibility of higher resolution PET scanners due to a significant reduction in the detector form factor. The increased detector density requires a proportionally larger number of channels to interface the SiPM array with the backend digital signal processing necessary for eventual image reconstruction. This work presents a CMOS ASIC design for signal reducing readout electronics in support of an 8×8 silicon photomultiplier array. The row/column/diagonal summation circuit significantly reduces the number of required channels, reducing the cost of subsequent digitizing electronics. Current amplifiers are used with a single input from each SiPM cathode. This approach helps to reduce the detector loading, while generating all the necessary row, column and diagonal addressing information. In addition, the single current amplifier used in our Pulse-Positioning architecture facilitates the extraction of pulse timing information. Other components under design at present include a current-mode comparator which enables threshold detection for dark noise current reduction, a transimpedance amplifier and a variable output impedance I/O driver which adapts to a wide range of loading conditions between the ASIC and lines with the off-chip Analog-to-Digital Converters (ADCs).

Entities:  

Year:  2012        PMID: 24301987      PMCID: PMC3843353          DOI: 10.1109/nssmic.2012.6551814

Source DB:  PubMed          Journal:  IEEE Nucl Sci Symp Conf Rec (1997)        ISSN: 1095-7863


  4 in total

1.  Evolution of the Design of a Second Generation FireWire Based Data Acquisition System.

Authors:  T K Lewellen; R S Miyaoka; L R Macdonald; M Haselman; D Dewitt; S Hauck
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2010-10-30

2.  An 8×8 Row-Column Summing Readout Electronics for Preclinical Positron Emission Tomography Scanners.

Authors:  Y C Shih; F W Sun; L R Macdonald; B P Otis; R S Miyaoka; W McDougald; T K Lewellen
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2009-10-24

3.  Design and Characteristics of a Multichannel Front-End ASIC Using Current-Mode CSA for Small-Animal PET Imaging.

Authors:  N Ollivier-Henry; N A Mbow; D Brasse; B Humbert; C Hu-Guo; C Colledani
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2011-02       Impact factor: 3.833

4.  A CMOS ASIC Design for SiPM Arrays.

Authors:  Samrat Dey; Lushon Banks; Shaw-Pin Chen; Wenbin Xu; Thomas K Lewellen; Robert S Miyaoka; Jacques C Rudell
Journal:  IEEE Trans Nucl Sci       Date:  2011-12       Impact factor: 1.679

  4 in total
  1 in total

1.  A CMOS Front-End Interface ASIC for SiPM-based Positron Emission Tomography Imaging Systems.

Authors:  Samrat Dey; Jacques C Rudell; Thomas K Lewellen; Robert S Miyaoka
Journal:  IEEE Biomed Circuits Syst Conf       Date:  2018-03-29
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.