Literature DB >> 24300967

A simple cassette as point-of-care diagnostic device for naked-eye colorimetric bacteria detection.

Mohammadali Safavieh1, Minhaz Uddin Ahmed, Esen Sokullu, Andy Ng, Liliana Braescu, Mohammed Zourob.   

Abstract

Effective pathogen detection is necessary for treatment of infectious diseases. Point of care (POC) devices have tremendously improved the global human heath. However, design criteria for sample processing POC devices for pathogen detection in limited infrastructure are challenging and can make a significant contribution to global health by providing rapid and sensitive detection of bacteria in food, water, and patient samples. In this paper, we demonstrate a novel portable POC diagnostic device that is simple to assemble for genetic detection of bacterial pathogens by isothermal DNA amplification. The device is fabricated with very low production cost, using simple methods and easy-to-access materials on a flexible ribbon polyethylene substrate. We showed that the device is capable of detection of 30 CFU mL(-1) of E. coli and 200 CFU mL(-1) of S. aureus in less than 1 hour. Through numerical simulations, we estimated that the device can be extended to high-throughput detection simultaneously performing a minimum of 36 analyses. This robust and sensitive detection device can be assembled and operated by non-specialist personnel, particularly for multiple bacterial pathogen detections in low-resource settings.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24300967     DOI: 10.1039/c3an01859h

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  21 in total

1.  Surface cytometer for fluorescent detection and growth monitoring of bacteria over a large field-of-view.

Authors:  Rafaël Sibilo; Juan Miguel Pérez; Cedric Hurth; Valerio Pruneri
Journal:  Biomed Opt Express       Date:  2019-03-28       Impact factor: 3.732

2.  Emerging Loop-Mediated Isothermal Amplification-Based Microchip and Microdevice Technologies for Nucleic Acid Detection.

Authors:  Mohammadali Safavieh; Manoj K Kanakasabapathy; Farhang Tarlan; Minhaz U Ahmed; Mohammed Zourob; Waseem Asghar; Hadi Shafiee
Journal:  ACS Biomater Sci Eng       Date:  2016-01-21

3.  Engineering a simple lateral flow device for animal blood coagulation monitoring.

Authors:  Hua Li; Daewoo Han; Giovanni M Pauletti; Andrew J Steckl
Journal:  Biomicrofluidics       Date:  2018-01-23       Impact factor: 2.800

4.  Geometrical-optics approach to measure the optical density of bacterial cultures using a LED-based photometer.

Authors:  Massimiliano Lucidi; Marco Marsan; Francesco Pudda; Mattia Pirolo; Emanuela Frangipani; Paolo Visca; Gabriella Cincotti
Journal:  Biomed Opt Express       Date:  2019-10-08       Impact factor: 3.732

5.  Paper microchip with a graphene-modified silver nano-composite electrode for electrical sensing of microbial pathogens.

Authors:  Mohammadali Safavieh; Vivasvat Kaul; Sultan Khetani; Anupriya Singh; Karan Dhingra; Manoj Kumar Kanakasabapathy; Mohamed Shehata Draz; Adnan Memic; Daniel R Kuritzkes; Hadi Shafiee
Journal:  Nanoscale       Date:  2017-02-02       Impact factor: 7.790

6.  Rapid Real-Time Antimicrobial Susceptibility Testing with Electrical Sensing on Plastic Microchips with Printed Electrodes.

Authors:  Mohammadali Safavieh; Hardik J Pandya; Maanasa Venkataraman; Prudhvi Thirumalaraju; Manoj Kumar Kanakasabapathy; Anupriya Singh; Devbalaji Prabhakar; Manjyot Kaur Chug; Hadi Shafiee
Journal:  ACS Appl Mater Interfaces       Date:  2017-03-30       Impact factor: 9.229

Review 7.  Flexible Substrate-Based Devices for Point-of-Care Diagnostics.

Authors:  ShuQi Wang; Thiruppathiraja Chinnasamy; Mark A Lifson; Fatih Inci; Utkan Demirci
Journal:  Trends Biotechnol       Date:  2016-06-22       Impact factor: 19.536

8.  A fully battery-powered inexpensive spectrophotometric system for high-sensitivity point-of-care analysis on a microfluidic chip.

Authors:  Maowei Dou; Juan Lopez; Misael Rios; Oscar Garcia; Chuan Xiao; Michael Eastman; XiuJun Li
Journal:  Analyst       Date:  2016-05-04       Impact factor: 4.616

Review 9.  Point-of-Care Diagnostics: Recent Developments in a Connected Age.

Authors:  Samiksha Nayak; Nicole R Blumenfeld; Tassaneewan Laksanasopin; Samuel K Sia
Journal:  Anal Chem       Date:  2016-12-13       Impact factor: 6.986

10.  Quantitative determination of target gene with electrical sensor.

Authors:  Xuzhi Zhang; Qiufen Li; Xianshi Jin; Cheng Jiang; Yong Lu; Roya Tavallaie; J Justin Gooding
Journal:  Sci Rep       Date:  2015-07-24       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.