Literature DB >> 24297040

Continuous flow real-time PCR device using multi-channel fluorescence excitation and detection.

Andrew C Hatch1, Tathagata Ray, Kelly Lintecum, Cody Youngbull.   

Abstract

High throughput automation is greatly enhanced using techniques that employ conveyor belt strategies with un-interrupted streams of flow. We have developed a 'conveyor belt' analog for high throughput real-time quantitative Polymerase Chain Reaction (qPCR) using droplet emulsion technology. We developed a low power, portable device that employs LED and fiber optic fluorescence excitation in conjunction with a continuous flow thermal cycler to achieve multi-channel fluorescence detection for real-time fluorescence measurements. Continuously streaming fluid plugs or droplets pass through tubing wrapped around a two-temperature zone thermal block with each wrap of tubing fluorescently coupled to a 64-channel multi-anode PMT. This work demonstrates real-time qPCR of 0.1-10 μL droplets or fluid plugs over a range of 7 orders of magnitude concentration from 1 × 10(1) to 1 × 10(7). The real-time qPCR analysis allows dynamic range quantification as high as 1 × 10(7) copies per 10 μL reaction, with PCR efficiencies within the range of 90-110% based on serial dilution assays and a limit of detection of 10 copies per rxn. The combined functionality of continuous flow, low power thermal cycling, high throughput sample processing, and real-time qPCR improves the rates at which biological or environmental samples can be continuously sampled and analyzed.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24297040     DOI: 10.1039/c3lc51236c

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  10 in total

Review 1.  A review on microscale polymerase chain reaction based methods in molecular diagnosis, and future prospects for the fabrication of fully integrated portable biomedical devices.

Authors:  Nae Yoon Lee
Journal:  Mikrochim Acta       Date:  2018-05-08       Impact factor: 5.833

2.  A BODIPY-Based Donor/Donor-Acceptor System: Towards Highly Efficient Long-Wavelength-Excitable Near-IR Polymer Dots with Narrow and Strong Absorption Features.

Authors:  Lei Chen; Dandan Chen; Yifei Jiang; Jicheng Zhang; Jiangbo Yu; Christopher C DuFort; Sunil R Hingorani; Xuanjun Zhang; Changfeng Wu; Daniel T Chiu
Journal:  Angew Chem Int Ed Engl       Date:  2019-04-12       Impact factor: 15.336

Review 3.  Nucleic Acids Analysis.

Authors:  Yongxi Zhao; Xiaolei Zuo; Qian Li; Feng Chen; Yan-Ru Chen; Jinqi Deng; Da Han; Changlong Hao; Fujian Huang; Yanyi Huang; Guoliang Ke; Hua Kuang; Fan Li; Jiang Li; Min Li; Na Li; Zhenyu Lin; Dingbin Liu; Juewen Liu; Libing Liu; Xiaoguo Liu; Chunhua Lu; Fang Luo; Xiuhai Mao; Jiashu Sun; Bo Tang; Fei Wang; Jianbin Wang; Lihua Wang; Shu Wang; Lingling Wu; Zai-Sheng Wu; Fan Xia; Chuanlai Xu; Yang Yang; Bi-Feng Yuan; Quan Yuan; Chao Zhang; Zhi Zhu; Chaoyong Yang; Xiao-Bing Zhang; Huanghao Yang; Weihong Tan; Chunhai Fan
Journal:  Sci China Chem       Date:  2020-12-02       Impact factor: 9.445

4.  Diameter-definable tubing-microchips for applications in both continuous-flow and TEC-modulated on-chip qPCRs with reaction signal analyzed between different types of Teflon-polymers: PTFE and FEP.

Authors:  Yangyang Jiang; Guizhu Wu; Yuanming Li; Wenming Wu
Journal:  RSC Adv       Date:  2019-01-21       Impact factor: 3.361

5.  Miniaturized Continuous-Flow Digital PCR for Clinical-Level Serum Sample Based on the 3D Microfluidics and CMOS Imaging Device.

Authors:  Bin Li; Yuanming Li; Andreas Manz; Wenming Wu
Journal:  Sensors (Basel)       Date:  2020-04-28       Impact factor: 3.576

6.  Compressed Air-Driven Continuous-Flow Thermocycled Digital PCR for HBV Diagnosis in Clinical-Level Serum Sample Based on Single Hot Plate.

Authors:  Kangning Wang; Bin Li; Wenming Wu
Journal:  Molecules       Date:  2020-11-30       Impact factor: 4.411

7.  Heat and pressure-resistant room temperature irreversible sealing of hybrid PDMS-thermoplastic microfluidic devices via carbon-nitrogen covalent bonding and its application in a continuous-flow polymerase chain reaction.

Authors:  Rajamanickam Sivakumar; Kieu The Loan Trinh; Nae Yoon Lee
Journal:  RSC Adv       Date:  2020-04-25       Impact factor: 3.361

Review 8.  Microfluidic Devices for Forensic DNA Analysis: A Review.

Authors:  Brigitte Bruijns; Arian van Asten; Roald Tiggelaar; Han Gardeniers
Journal:  Biosensors (Basel)       Date:  2016-08-05

Review 9.  Lab-on-Chip for Exosomes and Microvesicles Detection and Characterization.

Authors:  Maria Serena Chiriacò; Monica Bianco; Annamaria Nigro; Elisabetta Primiceri; Francesco Ferrara; Alessandro Romano; Angelo Quattrini; Roberto Furlan; Valentina Arima; Giuseppe Maruccio
Journal:  Sensors (Basel)       Date:  2018-09-20       Impact factor: 3.576

10.  A digital PCR system based on the thermal cycled chip with multi helix winding capillary.

Authors:  Bin Li; Yuanming Li; Yangyang Jiang; Andreas Manz; Wenming Wu
Journal:  Sci Rep       Date:  2020-10-20       Impact factor: 4.379

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.