Literature DB >> 24286131

Ultrasound elastography is a reproducible and feasible tool for the evaluation of the patellar tendon in healthy subjects.

F Porta1, N Damjanov, F Galluccio, A Iagnocco, M Matucci-Cerinic.   

Abstract

OBJECTIVE: To evaluate the feasibility and reproducibility of ultrasound elastography (UE) in the assessment of healthy patellar tendon and to describe its UE pattern.
METHODS: Twenty-two patellar tendons of 11 out of 16 healthy subjects who met the inclusion criteria were evaluated three times by ultrasound (US) and UE at their proximal, middle and distal portions, by two separate sonographers with different experiences in UE.
RESULTS: In all tendon portions the color map analysis showed a predominance of green (highly elastic), with good values of intra-observer (Operator 1: P-values = 0.790, 0.864, 0.865; Operator 2: P = 0.642, 0.882, 0.613 for proximal, middle and distal portions, respectively) and inter-observer (P = 0.657) agreement. For both operators the intra-observer analysis of the elasticity ratio (ER) between the tendon and the subcutis showed high agreement values (P < 0.001 for both operators). The inter-observer analysis showed also high agreement values (P < 0.001 at proximal, P = 0.001 at middle, P = 0.005 at distal portions). The overall analysis of the ER of the tendon portions showed values of (mean ± SD): 1.47 ± 0.64, 4.38 ± 1.36, 3.32 ± 1.20 for proximal, middle and distal portions, respectively. The mean time to perform the UE evaluation for the inexperienced operator was 5 min at the beginning of the study but decreased to 2 min after a few examinations were done. The mean time for the expert was 2 min for the entire study.
CONCLUSIONS: UE is a feasible and reproducible tool for the evaluation of the healthy patellar tendon and further data are needed to define its role in the assessment of tendon pathology.
© 2013 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.

Keywords:  feasibility; healthy subjects; patellar tendon; reproducibility; ultrasound elastography

Mesh:

Year:  2013        PMID: 24286131     DOI: 10.1111/1756-185X.12241

Source DB:  PubMed          Journal:  Int J Rheum Dis        ISSN: 1756-1841            Impact factor:   2.454


  14 in total

1.  Non-uniform Stiffness within Gastrocnemius-Achilles tendon Complex Observed after Static Stretching.

Authors:  Jiping Zhou; Chunlong Liu; Zhijie Zhang
Journal:  J Sports Sci Med       Date:  2019-08-01       Impact factor: 2.988

2.  Measuring stiffness of normal medial collateral ligament in healthy volunteers via shear wave elastography.

Authors:  Enes Gürün; Mehmet Aksakal; İsmail Akdulum
Journal:  Surg Radiol Anat       Date:  2021-04-19       Impact factor: 1.246

Review 3.  Ultrasound elastography in tendon pathology: state of the art.

Authors:  Romain Domenichini; Jean-Baptiste Pialat; Andrea Podda; Sébastien Aubry
Journal:  Skeletal Radiol       Date:  2017-08-01       Impact factor: 2.199

4.  Poor reproducibility of compression elastography in the Achilles tendon: same day and consecutive day measurements.

Authors:  Catherine Payne; Nick Webborn; Peter Watt; Mara Cercignani
Journal:  Skeletal Radiol       Date:  2017-04-04       Impact factor: 2.199

5.  Assessment of knee collateral ligament stiffness by strain ultrasound elastography.

Authors:  Surangika Wadugodapitiya; Makoto Sakamoto; Masaei Tanaka; Yuta Sakagami; Yusuke Morise; Koichi Kobayashi
Journal:  Biomed Mater Eng       Date:  2022       Impact factor: 1.234

6.  Reliability of ultrasound strain elastography in the assessment of the quadriceps and patellar tendon in healthy adults.

Authors:  Diane M Dickson; Henrietta O Fawole; Lisa Newcombe; Stephanie L Smith; Gordon J Hendry
Journal:  Ultrasound       Date:  2019-06-24

Review 7.  Ultrasound elastography: compression elastography and shear-wave elastography in the assessment of tendon injury.

Authors:  Rui Prado-Costa; João Rebelo; João Monteiro-Barroso; Ana Sofia Preto
Journal:  Insights Imaging       Date:  2018-08-17

8.  Real-time sonoelastography: principles and clinical applications in tendon disorders. A systematic review.

Authors:  Federico Fusini; Francesco Langella; Alberto Busilacchi; Cosimo Tudisco; Antonio Gigante; Alessandro Massé; Salvatore Bisicchia
Journal:  Muscles Ligaments Tendons J       Date:  2018-01-10

9.  Objective Assessment of Regional Stiffness in Vastus Lateralis with Different Measurement Methods: A Reliability Study.

Authors:  Alfredo Bravo-Sánchez; Pablo Abián; Jorge Sánchez-Infante; Paula Esteban-Gacía; Fernando Jiménez; Javier Abián-Vicén
Journal:  Sensors (Basel)       Date:  2021-05-06       Impact factor: 3.576

10.  Analisys of pectoralis major tendon in weightlifting athletes using ultrasonography and elastography.

Authors:  Alberto de Castro Pochini; Mario Ferretti; Eduardo Felipe Kin Ito Kawakami; Artur da Rocha Corrêa Fernandes; Andre Fukunishi Yamada; Gabriela Clemente de Oliveira; Moisés Cohen; Carlos Vicente Andreoli; Benno Ejnisman
Journal:  Einstein (Sao Paulo)       Date:  2015 Oct-Dec
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.