OBJECTIVES: Balloon valvuloplasty (BV) before transcatheter aortic implantation has been thought to be mandatory before the valve is implanted. We have explored the feasibility and safety of direct implantation of balloon expandable Edwards SAPIEN XT valve without prior balloon dilatation. BACKGROUND: Some complications after transcatheter aortic valve replacement (TAVR) have been associated with unwanted effects of BV, mainly the contribution to stroke and severe aortic regurgitation (AR) before the valve is implanted. Direct implantation with a self-expanding aortic valve has been recently reported. METHODS: From November 2011 to April 2012, ten patients were selected that met the following criteria in the transesophageal echocardiography (TEE): moderate calcification, homogeneous distribution of calcium, symmetrical opening of the valve, and some degree of aortic insufficiency. RESULTS: All patients had symptomatic aortic stenosis of a native valve and high surgical risk; six patients had the valve mildly calcified, in four patients the degree of calcification was moderate. The native valve was crossed and the prosthetic aortic valve was properly positioned in all cases and implanted in the correct position. No patient underwent post-dilatation and trivial AR was present in four patients. There were no adverse events (death, need for pacemaker, myocardial infarction, or stroke). At 30 days post-procedure, all patients were alive and had significant clinical improvement. CONCLUSIONS: Direct implantation of Edwards SAPIEN XT without prior BV in selected cases is feasible and safe. The number of patients in whom this technique would be applicable, and their impact on reducing complications has to be determined.
OBJECTIVES:Balloon valvuloplasty (BV) before transcatheter aortic implantation has been thought to be mandatory before the valve is implanted. We have explored the feasibility and safety of direct implantation of balloon expandable Edwards SAPIEN XT valve without prior balloon dilatation. BACKGROUND: Some complications after transcatheter aortic valve replacement (TAVR) have been associated with unwanted effects of BV, mainly the contribution to stroke and severe aortic regurgitation (AR) before the valve is implanted. Direct implantation with a self-expanding aortic valve has been recently reported. METHODS: From November 2011 to April 2012, ten patients were selected that met the following criteria in the transesophageal echocardiography (TEE): moderate calcification, homogeneous distribution of calcium, symmetrical opening of the valve, and some degree of aortic insufficiency. RESULTS: All patients had symptomatic aortic stenosis of a native valve and high surgical risk; six patients had the valve mildly calcified, in four patients the degree of calcification was moderate. The native valve was crossed and the prosthetic aortic valve was properly positioned in all cases and implanted in the correct position. No patient underwent post-dilatation and trivial AR was present in four patients. There were no adverse events (death, need for pacemaker, myocardial infarction, or stroke). At 30 days post-procedure, all patients were alive and had significant clinical improvement. CONCLUSIONS: Direct implantation of Edwards SAPIEN XT without prior BV in selected cases is feasible and safe. The number of patients in whom this technique would be applicable, and their impact on reducing complications has to be determined.
Authors: Lenard Conradi; Andreas Schaefer; Moritz Seiffert; Johannes Schirmer; Ulrich Schaefer; Gerhard Schön; Stefan Blankenberg; Hermann Reichenspurner; Hendrik Treede; Patrick Diemert Journal: Clin Res Cardiol Date: 2015-03-01 Impact factor: 5.460
Authors: Matteo Pagnesi; Luca Baldetti; Paolo Del Sole; Antonio Mangieri; Marco B Ancona; Damiano Regazzoli; Nicola Buzzatti; Francesco Giannini; Antonio Colombo; Azeem Latib Journal: Interv Cardiol Date: 2017-09
Authors: Anupama Shivaraju; Christian Thilo; Neal Sawlani; Ilka Ott; Heribert Schunkert; Wolfgang von Scheidt; Adnan Kastrati; Albert Markus Kasel Journal: Biomed Res Int Date: 2018-04-30 Impact factor: 3.411