Literature DB >> 24272142

Automated detection of perinatal hypoxia using time-frequency-based heart rate variability features.

Shiying Dong1, Boualem Boashash, Ghasem Azemi, Barbara E Lingwood, Paul B Colditz.   

Abstract

Perinatal hypoxia is a cause of cerebral injury in foetuses and neonates. Detection of foetal hypoxia during labour based on the pattern recognition of heart rate signals suffers from high observer variability and low specificity. We describe a new automated hypoxia detection method using time-frequency analysis of heart rate variability (HRV) signals. This approach uses features extracted from the instantaneous frequency and instantaneous amplitude of HRV signal components as well as features based on matrix decomposition of the signals' time-frequency distributions using singular value decomposition and non-negative matrix factorization. The classification between hypoxia and non-hypoxia data is performed using a support vector machine classifier. The proposed method is tested on a dataset obtained from a newborn piglet model with a controlled hypoxic insult. The chosen HRV features show strong performance compared to conventional spectral features and other existing methods of hypoxia detection with a sensitivity 93.3 %, specificity 98.3 % and accuracy 95.8 %. The high predictive value of this approach to detecting hypoxia is a substantial step towards developing a more accurate and reliable hypoxia detection method for use in human foetal monitoring.

Entities:  

Mesh:

Year:  2013        PMID: 24272142     DOI: 10.1007/s11517-013-1129-3

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  19 in total

1.  Computerised intrapartum diagnosis of fetal hypoxia based on fetal heart rate monitoring and fetal pulse oximetry recordings utilising wavelet analysis and neural networks.

Authors:  E Salamalekis; P Thomopoulos; D Giannaris; I Salloum; G Vasios; A Prentza; D Koutsouris
Journal:  BJOG       Date:  2002-10       Impact factor: 6.531

2.  Detection of asphyxia using heart rate variability.

Authors:  A Boardman; F S Schlindwein; N V Thakor; T Kimura; R G Geocadin
Journal:  Med Biol Eng Comput       Date:  2002-11       Impact factor: 2.602

3.  Instantaneous parameter estimation in cardiovascular time series by harmonic and time-frequency analysis.

Authors:  Alessandro Monti; Claire Médigue; Laurence Mangin
Journal:  IEEE Trans Biomed Eng       Date:  2002-12       Impact factor: 4.538

4.  A method for continuously assessing the autonomic response to music-induced emotions through HRV analysis.

Authors:  Michele Orini; Raquel Bailón; Ronny Enk; Stefan Koelsch; Luca Mainardi; Pablo Laguna
Journal:  Med Biol Eng Comput       Date:  2010-03-19       Impact factor: 2.602

5.  Predicting the risk of metabolic acidosis for newborns based on fetal heart rate signal classification using support vector machines.

Authors:  George Georgoulas; Chrysostomos D Stylios; Peter P Groumpos
Journal:  IEEE Trans Biomed Eng       Date:  2006-05       Impact factor: 4.538

Review 6.  Heart rate variability as a measure of autonomic regulation of cardiac activity for assessing stress and welfare in farm animals -- a review.

Authors:  Eberhard von Borell; Jan Langbein; Gérard Després; Sven Hansen; Christine Leterrier; Jeremy Marchant-Forde; Ruth Marchant-Forde; Michela Minero; Elmar Mohr; Armelle Prunier; Dorothée Valance; Isabelle Veissier
Journal:  Physiol Behav       Date:  2007-01-20

7.  Fetal blood sampling in addition to intrapartum ST-analysis of the fetal electrocardiogram: evaluation of the recommendations in the Dutch STAN® trial.

Authors:  J H Becker; M E M H Westerhuis; K Sterrenburg; E S A van den Akker; E van Beek; A C Bolte; T J H M van Dessel; A P Drogtrop; H P van Geijn; G C M Graziosi; J M M van Lith; B W J Mol; K G M Moons; J G Nijhuis; S G Oei; H P Oosterbaan; M M Porath; R J P Rijnders; N W E Schuitemaker; L D E Wijnberger; C Willekes; G H A Visser; A Kwee
Journal:  BJOG       Date:  2011-06-14       Impact factor: 6.531

8.  Automatic evaluation of intrapartum fetal heart rate recordings: a comprehensive analysis of useful features.

Authors:  V Chudáček; J Spilka; P Janků; M Koucký; L Lhotská; M Huptych
Journal:  Physiol Meas       Date:  2011-07-15       Impact factor: 2.833

Review 9.  New perspectives in electronic fetal surveillance.

Authors:  Emily F Hamilton; Philip A Warrick
Journal:  J Perinat Med       Date:  2013-01       Impact factor: 1.901

10.  The 2008 National Institute of Child Health and Human Development workshop report on electronic fetal monitoring: update on definitions, interpretation, and research guidelines.

Authors:  George A Macones; Gary D V Hankins; Catherine Y Spong; John Hauth; Thomas Moore
Journal:  Obstet Gynecol       Date:  2008-09       Impact factor: 7.661

View more
  3 in total

1.  An automatic method for arterial pulse waveform recognition using KNN and SVM classifiers.

Authors:  Tânia Pereira; Joana S Paiva; Carlos Correia; João Cardoso
Journal:  Med Biol Eng Comput       Date:  2015-09-24       Impact factor: 2.602

Review 2.  Cardiotocography and beyond: a review of one-dimensional Doppler ultrasound application in fetal monitoring.

Authors:  Faezeh Marzbanrad; Lisa Stroux; Gari D Clifford
Journal:  Physiol Meas       Date:  2018-08-14       Impact factor: 2.833

3.  Novel characterization method of impedance cardiography signals using time-frequency distributions.

Authors:  Jesús Escrivá Muñoz; Y Pan; S Ge; E W Jensen; M Vallverdú
Journal:  Med Biol Eng Comput       Date:  2018-03-16       Impact factor: 2.602

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.