Literature DB >> 24270713

Round window insertion of precurved electrodes is traumatic.

Anita Jeyakumar1, Sarah F Peña, Todd M Brickman.   

Abstract

OBJECTIVE: Assess endocochlear trauma by adjusting: 1) location of cochleostomy or round window insertion, and 2) size of precontoured electrode array. STUDY
DESIGN: Cadaveric temporal bone study.
METHODS: Locations of electrode placement into the cochlea were as follows: 1) round window, 2) anterior inferior to the round window, 3) anterior inferior to the round window niche, 4) superior to the round window niche. Two types of electrode arrays were used: a larger precontoured electrode and thinner precurved research electrode. Histologic sections were made by a blinded third party.
RESULTS: Fourteen bones were included in the study. Six (42.8%) of the bones were right ears. Seven bones had no endocochlear trauma. Seven bones have intracochlear trauma. Round window insertions had a high incidence of intracochlear trauma with precontoured electrodes (3/4 bones). Superior cochleostomies with electrode placement had significant intracochlear trauma (2/2 bones). Insertions made anterior inferior to the round window annulus had a 50% incidence of intracochlear trauma (2/4 bones). No endocochlear trauma observed for insertions through traditional cochleostomies (4/4 bones). Less endocochlear trauma was observed with the thinner electrode: 57% versus 42% in the larger electrode array. A higher incidence of tip fold-over was observed with the thinner electrode array (2/7 electrodes). No tip fold-over was noted in the larger electrode.
CONCLUSION: The traditional cochleostomy had the least incidence of endocochlear trauma. The smaller electrode array did not significantly affect the incidence of endocochlear trauma, but the thinner array had a higher incidence of tip fold-over, which caused trauma distally. LEVEL OF EVIDENCE: 2C.

Entities:  

Mesh:

Year:  2014        PMID: 24270713     DOI: 10.1097/MAO.0000000000000194

Source DB:  PubMed          Journal:  Otol Neurotol        ISSN: 1531-7129            Impact factor:   2.311


  4 in total

1.  Evaluation of a new slim lateral wall electrode for cochlear implantation: an imaging study in human temporal bones.

Authors:  Aarno Dietz; Matti Iso-Mustajärvi; Sini Sipari; Jyrki Tervaniemi; Dzemal Gazibegovic
Journal:  Eur Arch Otorhinolaryngol       Date:  2018-05-24       Impact factor: 2.503

2.  Multicenter surgical experience evaluation on the Mid-Scala electrode and insertion tools.

Authors:  Dzemal Gazibegovic; Eva M Bero
Journal:  Eur Arch Otorhinolaryngol       Date:  2016-08-11       Impact factor: 2.503

3.  An In-Vitro Insertion-Force Study of Magnetically Guided Lateral-Wall Cochlear-Implant Electrode Arrays.

Authors:  Lisandro Leon; Frank M Warren; Jake J Abbott
Journal:  Otol Neurotol       Date:  2018-02       Impact factor: 2.311

4.  The effect of the surgical approach and cochlear implant electrode on the structural integrity of the cochlea in human temporal bones.

Authors:  Saad Jwair; Huib Versnel; Robert J Stokroos; Hans G X M Thomeer
Journal:  Sci Rep       Date:  2022-10-12       Impact factor: 4.996

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.