Literature DB >> 24270234

Outcomes after implantable left ventricular assist device replacement procedures.

Matthew A Schechter1, Mani A Daneshmand, Chetan B Patel, Laura J Blue, Joseph G Rogers, Carmelo A Milano.   

Abstract

As the duration of support increases for patients with continuous flow left ventricular assist devices (LVADs), device replacement may still be necessary for a variety of indications. Outcomes after replacement LVAD surgeries have not been extensively described, and whether these patients experience outcomes similar to primary LVAD implant patients remains unclear. From 2003 to 2012, 342 consecutive implantable LVAD procedures took place at a single institution, of which 201 were considered destination therapy. Within this larger group, 30 patients underwent 35 replacement procedures. The three major indications for replacement LVAD procedures were mechanical/electrical failure (57%), hemolysis/thrombosis (29%), and infection (14%). Propensity matching using preoperative characteristics was used to generate a primary implant control group to determine the impact of the replacement status on outcomes. Thirty-day and 1-year survival after LVAD replacement was 90% and 48%, respectively. Survival outcomes were worse for patients undergoing device replacement compared with the matched primary cohort (p = 0.03). The need for transfusion and the incidence of postoperative right ventricular and renal dysfunction were similar between the two groups, as was length of hospitalization. There was no difference between the rates of postoperative infection or stroke. Emergent replacement procedures had a higher mortality than those done nonemergently. Given these findings, earlier timing for replacement, temporary stabilization with an extracorporeal device, and use of a nonsternotomy surgical approach should be investigated as strategies to improve outcomes.

Entities:  

Mesh:

Year:  2014        PMID: 24270234      PMCID: PMC4330192          DOI: 10.1097/MAT.0000000000000011

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  7 in total

1.  Replacement of continuous-flow left ventricular assist device via left subcostal incision.

Authors:  Joseph G Rogers; James G Jollis; Carmelo A Milano
Journal:  J Thorac Cardiovasc Surg       Date:  2011-10-27       Impact factor: 5.209

2.  Left ventricular assist device performance with long-term circulatory support: lessons from the REMATCH trial.

Authors:  Walter P Dembitsky; Alfred J Tector; Soon Park; Alan J Moskowitz; Annetine C Gelijns; Nuala S Ronan; William Piccione; William L Holman; Satoshi Furukawa; Alan D Weinberg; Gerald Heatley; Victor L Poirier; Laura Damme; James W Long
Journal:  Ann Thorac Surg       Date:  2004-12       Impact factor: 4.330

3.  HeartMate left ventricular assist system exchange: results and technical considerations.

Authors:  Robert M Adamson; Walter P Dembitsky; Sam Baradarian; Joseph Chammas; Brian Jaski; Peter Hoagland; Vicki McCalmont; Kristi Ortiz; Marsha Stahovich; Suzanne Chillcott
Journal:  ASAIO J       Date:  2009 Nov-Dec       Impact factor: 2.872

4.  Exchange techniques for implantable ventricular assist devices.

Authors:  Igor D Gregoric
Journal:  ASAIO J       Date:  2008 Jan-Feb       Impact factor: 2.872

5.  Device exchange after primary left ventricular assist device implantation: indications and outcomes.

Authors:  John M Stulak; Jennifer Cowger; Jonathon W Haft; Matthew A Romano; Keith D Aaronson; Francis D Pagani
Journal:  Ann Thorac Surg       Date:  2012-10-11       Impact factor: 4.330

6.  Advanced heart failure treated with continuous-flow left ventricular assist device.

Authors:  Mark S Slaughter; Joseph G Rogers; Carmelo A Milano; Stuart D Russell; John V Conte; David Feldman; Benjamin Sun; Antone J Tatooles; Reynolds M Delgado; James W Long; Thomas C Wozniak; Waqas Ghumman; David J Farrar; O Howard Frazier
Journal:  N Engl J Med       Date:  2009-11-17       Impact factor: 91.245

7.  Pump replacement for left ventricular assist device failure can be done safely and is associated with low mortality.

Authors:  Nader Moazami; Carmelo A Milano; Ranjit John; Benjamin Sun; Robert M Adamson; Francis D Pagani; Nicholas Smedira; Mark S Slaughter; David J Farrar; O Howard Frazier
Journal:  Ann Thorac Surg       Date:  2012-12-20       Impact factor: 4.330

  7 in total
  5 in total

1.  Global Outcome in Patients With Left Ventricular Assist Devices.

Authors:  Timothy J Fendler; Michael E Nassif; Kevin F Kennedy; Susan M Joseph; Scott C Silvestry; Gregory A Ewald; Shane J LaRue; Justin M Vader; John A Spertus; Suzanne V Arnold
Journal:  Am J Cardiol       Date:  2017-01-05       Impact factor: 2.778

Review 2.  Durability of continuous-flow left ventricular assist devices: a systematic review.

Authors:  Ashleigh Xie; Kevin Phan; Tristan D Yan
Journal:  Ann Cardiothorac Surg       Date:  2014-11

3.  Baseline red blood cell osmotic fragility does not predict the degree of post-LVAD hemolysis.

Authors:  Jesse L Madden; Stavros G Drakos; Josef Stehlik; Stephen H McKellar; Matthew T Rondina; Andrew S Weyrich; Craig H Selzman
Journal:  ASAIO J       Date:  2014 Sep-Oct       Impact factor: 2.872

4.  Comparison of SynCardia total artificial heart and HeartWare HVAD biventricular support for management of biventricular heart failure: a systematic review and meta-analysis.

Authors:  Elizabeth J Maynes; Thomas J O'Malley; Jessica G Y Luc; Matthew P Weber; Dylan P Horan; Jae Hwan Choi; Sinal Patel; Syed-Saif Abbas Rizvi; Rohinton J Morris; John W Entwistle; H Todd Massey; Vakhtang Tchantchaleishvili
Journal:  Ann Cardiothorac Surg       Date:  2020-03

5.  Incidence and impact of acute kidney injury on patients with implantable left ventricular assist devices: a Meta-analysis.

Authors:  Charat Thongprayoon; Ploypin Lertjitbanjong; Wisit Cheungpasitporn; Panupong Hansrivijit; Tibor Fülöp; Karthik Kovvuru; Swetha R Kanduri; Paul W Davis; Saraschandra Vallabhajosyula; Tarun Bathini; Kanramon Watthanasuntorn; Narut Prasitlumkum; Ronpichai Chokesuwattanaskul; Supawat Ratanapo; Michael A Mao; Kianoush Kashani
Journal:  Ren Fail       Date:  2020-11       Impact factor: 2.606

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.