Detection of liquid phase cholesteryl ester in carotid atherosclerosis by 1H-MR spectroscopy in humans.

Raphaël Duivenvoorden1, Diederik van Wijk1, Michael Klimas2, John J P Kastelein1, Erik S G Stroes1, Aart J Nederveen3.   

Abstract

OBJECTIVES: This study hypothesized that (1)H magnetic resonance spectroscopy ((1)H-MRS) can identify carotid plaque cholesteryl ester in vivo in humans.
BACKGROUND: Liquid phase cholesteryl ester comprises a major fraction of atherosclerotic plaque, and its abundance is associated with plaque rupture and atherothrombosis. A noninvasive imaging technique to detect liquid cholesteryl ester that has been applied ex vivo is now demonstrated in vivo.
METHODS: (1)H-MRS scans were obtained of carotid plaques of 35 subjects at 3.0 T. Turbo spin echo, black blood, T1-weighted images were acquired for localization. Spectra were acquired using a 2-dimensional point resolved spectroscopy sequence: repetition time/echo time = 1,100/30 ms, 5-mm slice thickness, 8 × 8-cm field of view, 16 × 16 matrix size, and 13-min acquisition time. Saturation bands were placed around the artery. Resonance of methylene protons and allylic methylene protons were assigned to 1.2 ppm and 2.0 ppm. The 2.0:1.2 ppm ratio was calculated to reflect the ratio of the fatty acid composition of plaque cholesteryl ester to that of triglycerides of perivascular tissue. We obtained spectra of lipid standards as a reference.
RESULTS: Our (1)H-MRS data showed typical spectra of cholesteryl ester mixed with triglycerides, with intense resonance from methylene (1.2 ppm) and allylic methylene (2.0 ppm) protons. The average 2.0:1.2 ppm ratio was 0.10 ± 0.03. The 2.0:1.2 ppm ratio correlated with the plaque tissue volume to perivascular tissue volume ratio (Spearman rho = 0.55, p = 0.02), suggesting that more (1)H-MRS signal was obtained from cholesteryl ester when the (1)H-MRS voxel comprised more plaque tissue. Repeat (1)H-MRS scans in 4 subjects showed an intraclass correlation coefficient of 0.92 (95% prediction intervals: 0.40 to 0.99), indicating good reproducibility. Seventeen of the 35 (1)H-MRS spectra were of adequate quality for analysis.
CONCLUSIONS: In vivo image-guided (1)H-MRS for detection of liquid phase cholesteryl ester in carotid atherosclerotic plaques in humans is feasible.
Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  (1)H magnetic resonance spectroscopy; (1)H-MRS; MRI; TE; TR; atherosclerosis; cholesterol; echo time; magnetic resonance imaging; magnetic resonance spectroscopy; repetition time

Mesh:

Substances:

Year:  2013        PMID: 24269263     DOI: 10.1016/j.jcmg.2013.03.010

Source DB:  PubMed          Journal:  JACC Cardiovasc Imaging        ISSN: 1876-7591


  2 in total

Review 1.  Imaging atherosclerosis with hybrid positron emission tomography/magnetic resonance imaging.

Authors:  Rasmus Sejersten Ripa; Andreas Kjær
Journal:  Biomed Res Int       Date:  2015-01-28       Impact factor: 3.411

2.  Micro Spectroscopic Photoacoustic (μsPA) imaging of advanced carotid atherosclerosis.

Authors:  Sophinese Iskander-Rizk; Mirjam Visscher; Astrid M Moerman; Suze-Anne Korteland; Kim Van der Heiden; Antonius F W Van der Steen; Gijs Van Soest
Journal:  Photoacoustics       Date:  2021-03-18
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.