Ubong Ime Udoekwere1, Chintan S Oza2, Simon F Giszter3. 1. Drexel University College of Medicine, and School of Biomedical Engineering and Health Science, Drexel University, Philadelphia, PA, USA; OREC - Orthopaedic and Rehabilitation Engineering Center, Marquette University, Milwaukee, WI, USA. 2. Drexel University College of Medicine, and School of Biomedical Engineering and Health Science, Drexel University, Philadelphia, PA, USA. 3. Drexel University College of Medicine, and School of Biomedical Engineering and Health Science, Drexel University, Philadelphia, PA, USA. Electronic address: sgiszter@drexelmed.edu.
Abstract
BACKGROUND: Rodents are important model systems used to explore spinal cord injury (SCI) and rehabilitation, and brain machine interfaces (BMI). We present a new method to provide mechanical interaction for BMI and rehabilitation in rat models of SCI. NEW METHOD: We present the design and implantation procedures for a pelvic orthosis that allows direct force application to the skeleton in brain machine interface and robot rehabilitation applications in rodents. We detail the materials, construction, machining, surgery and validation of the device. RESULTS: We describe the statistical validation of the implant procedures by comparing stepping parameters of 8 rats prior to and after implantation and surgical recovery. An ANOVA showed no effects of the implantation on stepping. Paired tests in the individual rats also showed no effect in 7/8 rats and minor effects in the last rat, within the group's variance. COMPARISON WITH EXISTING METHODS: Our method allows interaction with rats at the pelvis without any perturbation of normal stepping in the intact rat. The method bypasses slings, and cuffs, avoiding cuff or slings squeezing the abdomen, or other altered sensory feedback. Our implant osseointegrates, and thus allows an efficient high bandwidth mechanical coupling to a robot. The implants support quadrupedal training and are readily integrated into either treadmill or overground contexts. CONCLUSIONS: Our novel device and procedures support a range of novel experimental designs and motor tests for rehabilitative and augmentation devices in intact and SCI model rats, with the advantage of allowing direct force application at the pelvic bones.
BACKGROUND: Rodents are important model systems used to explore spinal cord injury (SCI) and rehabilitation, and brain machine interfaces (BMI). We present a new method to provide mechanical interaction for BMI and rehabilitation in rat models of SCI. NEW METHOD: We present the design and implantation procedures for a pelvic orthosis that allows direct force application to the skeleton in brain machine interface and robot rehabilitation applications in rodents. We detail the materials, construction, machining, surgery and validation of the device. RESULTS: We describe the statistical validation of the implant procedures by comparing stepping parameters of 8 rats prior to and after implantation and surgical recovery. An ANOVA showed no effects of the implantation on stepping. Paired tests in the individual rats also showed no effect in 7/8 rats and minor effects in the last rat, within the group's variance. COMPARISON WITH EXISTING METHODS: Our method allows interaction with rats at the pelvis without any perturbation of normal stepping in the intact rat. The method bypasses slings, and cuffs, avoiding cuff or slings squeezing the abdomen, or other altered sensory feedback. Our implant osseointegrates, and thus allows an efficient high bandwidth mechanical coupling to a robot. The implants support quadrupedal training and are readily integrated into either treadmill or overground contexts. CONCLUSIONS: Our novel device and procedures support a range of novel experimental designs and motor tests for rehabilitative and augmentation devices in intact and SCI model rats, with the advantage of allowing direct force application at the pelvic bones.
Authors: Nadia Dominici; Urs Keller; Heike Vallery; Lucia Friedli; Rubia van den Brand; Michelle L Starkey; Pavel Musienko; Robert Riener; Grégoire Courtine Journal: Nat Med Date: 2012-07 Impact factor: 53.440
Authors: Vitor M Filipe; José E Pereira; Luís M Costa; Ana C Maurício; Pedro A Couto; Pedro Melo-Pinto; Artur S P Varejão Journal: J Neurosci Methods Date: 2005-12-07 Impact factor: 2.390
Authors: Ray D de Leon; Marc D Kubasak; Patricia E Phelps; Wojciech K Timoszyk; David J Reinkensmeyer; Roland R Roy; V Reggie Edgerton Journal: Brain Res Brain Res Rev Date: 2002-10