Literature DB >> 24268831

Performance characteristics of the verbal QuickDASH.

Daniel A London1, Jeffrey G Stepan2, Martin I Boyer2, Ryan P Calfee2.   

Abstract

PURPOSE: To quantify the performance of the verbally administered Quick Disabilities of the Arm, Shoulder, and Hand (QuickDASH) questionnaire by assessing its replication of self-administered scores, its test-retest reliability, and its rate of scorable completion compared with its self-administered, written administration.
METHODS: Fifty patients presenting for initial visits to a hand clinic were enrolled regardless of diagnosis. All patients completed a written and a verbal QuickDASH 1 day apart (25 patients written first; 25 patients verbal first). Intraclass correlation coefficients quantified the verbal questionnaire's ability to reproduce written scores. Participants verbally completed the questionnaire a final time, 5 months later, to assess test-retest reliability. To quantify the usability of survey data, we compared percentages of scorable surveys between written and verbally administered QuickDASH questionnaires in this study and in prior studies within our division.
RESULTS: The intraclass correlation coefficient between the 2 QuickDASH administration types for the entire sample was 0.91. Across all participants, there was a minimal change in mean score from a patient's written QuickDASH to that patient's first verbal QuickDASH score. Scoring consistency between QuickDASH administrations was similar for each administration sequence (phone followed by written vs. written followed by phone) and by diagnosis. Test-retest reliability between the 2 verbal administrations demonstrated good reliability and a minimal difference between scores. In this study, no written or verbal surveys were incomplete. Reviewing our practice, 17% of 258 written questionnaires produced unscorable data compared with 0% of 239 verbally administered surveys.
CONCLUSIONS: Our results indicate that verbal administration of the QuickDASH replicates clinically relevant scores of the written QuickDASH, has good test-retest performance, and may minimize unusable data. These data allow researchers greater flexibility in gathering patient outcome data in both retrospective and prospective studies. TYPE OF STUDY/LEVEL OF EVIDENCE: Diagnostic II.
Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  DASH; QuickDASH; outcome measure; reliability; verbal

Mesh:

Year:  2013        PMID: 24268831      PMCID: PMC3874250          DOI: 10.1016/j.jhsa.2013.09.041

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  31 in total

1.  A comparison of two time intervals for test-retest reliability of health status instruments.

Authors:  Robert G Marx; Alia Menezes; Lois Horovitz; Edward C Jones; Russell F Warren
Journal:  J Clin Epidemiol       Date:  2003-08       Impact factor: 6.437

2.  Sample size and optimal designs for reliability studies.

Authors:  S D Walter; M Eliasziw; A Donner
Journal:  Stat Med       Date:  1998-01-15       Impact factor: 2.373

3.  Development of an upper extremity outcome measure: the DASH (disabilities of the arm, shoulder and hand) [corrected]. The Upper Extremity Collaborative Group (UECG)

Authors:  P L Hudak; P C Amadio; C Bombardier
Journal:  Am J Ind Med       Date:  1996-06       Impact factor: 2.214

4.  The Physical Activity Scale for the Elderly (PASE): development and evaluation.

Authors:  R A Washburn; K W Smith; A M Jette; C A Janney
Journal:  J Clin Epidemiol       Date:  1993-02       Impact factor: 6.437

5.  A critical discussion of intraclass correlation coefficients.

Authors:  R Müller; P Büttner
Journal:  Stat Med       Date:  1994 Dec 15-30       Impact factor: 2.373

6.  Accuracy of patient recall of hand and elbow disability on the QuickDASH questionnaire over a two-year period.

Authors:  Jeffrey G Stepan; Daniel A London; Martin I Boyer; Ryan P Calfee
Journal:  J Bone Joint Surg Am       Date:  2013-11-20       Impact factor: 5.284

7.  Measuring the whole or the parts? Validity, reliability, and responsiveness of the Disabilities of the Arm, Shoulder and Hand outcome measure in different regions of the upper extremity.

Authors:  D E Beaton; J N Katz; A H Fossel; J G Wright; V Tarasuk; C Bombardier
Journal:  J Hand Ther       Date:  2001 Apr-Jun       Impact factor: 1.950

8.  Why do people report better health by phone than by mail?

Authors:  Noel T Brewer; William K Hallman; Nancy Fiedler; Howard M Kipen
Journal:  Med Care       Date:  2004-09       Impact factor: 2.983

9.  Patient rating of wrist pain and disability: a reliable and valid measurement tool.

Authors:  J C MacDermid; T Turgeon; R S Richards; M Beadle; J H Roth
Journal:  J Orthop Trauma       Date:  1998 Nov-Dec       Impact factor: 2.512

10.  Telephone validation of the Quality of Life in Epilepsy Inventory-89 (QOLIE-89).

Authors:  N K Leidy; A Elixhauser; A M Rentz; R Beach; J Pellock; S Schachter; M K William
Journal:  Epilepsia       Date:  1999-01       Impact factor: 5.864

View more
  13 in total

1.  The influence of dominant limb involvement on DASH and QuickDASH.

Authors:  Amir Reza Kachooei; Ali Moradi; Stein Jasper Janssen; David Ring
Journal:  Hand (N Y)       Date:  2015-09

2.  Oswestry Disability Index: Is Telephone Administration Valid?

Authors:  Christopher T Martin; Alexandra K Yaszemski; Charles G T Ledonio; Tara C Barrack; David W Polly
Journal:  Iowa Orthop J       Date:  2019

3.  Delivery of Patient-Reported Outcome Instruments by Automated Mobile Phone Text Messaging.

Authors:  Christopher A Anthony; Ericka A Lawler; Natalie A Glass; Katelyn McDonald; Apurva S Shah
Journal:  Hand (N Y)       Date:  2016-10-06

4.  High Irritation and Removal Rates After Plate or Nail Fixation in Patients With Displaced Midshaft Clavicle Fractures.

Authors:  Martijn H J Hulsmans; Mark van Heijl; R Marijn Houwert; Eric R Hammacher; Sven A G Meylaerts; Michiel H J Verhofstad; Marcel G W Dijkgraaf; Egbert J M M Verleisdonk
Journal:  Clin Orthop Relat Res       Date:  2016-11-09       Impact factor: 4.176

5.  Reliability of the revised Scoliosis Research Society-22 and Oswestry Disability Index (ODI) questionnaires in adult spinal deformity when administered by telephone.

Authors:  Steven L Bokshan; Jakub Godzik; Jonathan Dalton; Jennifer Jaffe; Lawrence G Lenke; Michael P Kelly
Journal:  Spine J       Date:  2016-03-17       Impact factor: 4.166

6.  High Risk of Further Surgery After Radial Head Replacement for Unstable Fractures: Longer-term Outcomes at a Minimum Follow-up of 8 Years.

Authors:  Caroline D Cristofaro; Thomas H Carter; Neil R Wickramasinghe; Margaret M McQueen; Timothy O White; Andrew D Duckworth
Journal:  Clin Orthop Relat Res       Date:  2019-11       Impact factor: 4.176

7.  Extra-articular Metacarpal Fractures: Closed Reduction and Percutaneous Pinning Versus Open Reduction and Internal Fixation.

Authors:  Vasileios Vasilakis; Catherine J Sinnott; Malack Hamade; Hassan Hamade; Brian A Pinsky
Journal:  Plast Reconstr Surg Glob Open       Date:  2019-05-21

8.  Reliability of Telephone Acquisition of the PROMIS Upper Extremity Computer Adaptive Test.

Authors:  John T Wilkinson; Jordan W Clawson; Chelsea M Allen; Angela P Presson; Andrew R Tyser; Nikolas H Kazmers
Journal:  J Hand Surg Am       Date:  2020-11-24       Impact factor: 2.230

9.  Validity and Reliability of the Persian Version of Shortened Disabilities of the Arm, Shoulder and Hand Questionnaire (Quick-DASH).

Authors:  Mohammad H Ebrahimzadeh; Ali Moradi; Ehsan Vahedi; Amir Reza Kachooei; Ali Birjandinejad
Journal:  Int J Prev Med       Date:  2015-07-08

10.  Can the Kerlan-Jobe Orthopaedic Clinic Shoulder and Elbow Score Be Reliably Administered Over the Phone?: A Randomized Study.

Authors:  Brandon J Erickson; Peter N Chalmers; Jon Newgren; Marissa Malaret; Michael O'Brien; Gregory P Nicholson; Anthony A Romeo
Journal:  Orthop J Sports Med       Date:  2018-08-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.