Literature DB >> 24268749

Is physiologic annular dynamics preserved after mitral valve repair with rigid or semirigid ring?

Masaaki Ryomoto1, Masataka Mitsuno1, Mitsuhiro Yamamura1, Hiroe Tanaka1, Shinya Fukui1, Noriko Tsujiya1, Tetsuya Kajiyama1, Yuji Miyamoto2.   

Abstract

BACKGROUND: Various rings are available to achieve more physiologic mitral valve repair from viewpoints of physiologic mitral annular structure or dynamics. We evaluated preoperative and postoperative mitral annular structures and dynamics.
METHODS: Thirty-six patients underwent mitral valve repair for degenerative mitral insufficiency. Carpentier-Edwards Physio II ring (semirigid [Edwards Lifesciences, Irvine, CA]), St. Jude Medical Rigid Saddle Ring (RSR [St. Jude Medical, St. Paul, MN]), and MEMO 3D ring (semirigid [Sorin SpA, Milan, Italy]) were implanted in 13, 12, and 11 patients, respectively. Intraoperative real-time three-dimensional transesophageal echocardiography was performed before and after repair.
RESULTS: The postoperative anteroposterior diameter reduction rate from end diastole to end systole was significantly (p<0.0001) larger in MEMO (9.58%±2.91%) than in Physio II (0.98%±1.04%) and RSR (1.94%±1.95%). There were no significant differences in the commissure-to-commissure diameter reduction rates among the groups: 0.81%±1.98% for Physio II, 0.12%±0.53% for RSR, and 0.51%±1.98% for MEMO. The postoperative end-systolic annular height commissure width ratio was significantly (p<0.0001) larger in both Physio II (17.9%±3.0%) and RSR (18.5%±1.6%) than in MEMO (13.6%±3.0%). The postoperative annular height commissure width ratio increase rate from end diastole to end systole was significantly larger in MEMO (5.1%±2.3%) than in Physio II (0.1%±0.6%) and RSR (0.3%±0.5%).
CONCLUSIONS: Physio II and RSR could restore the physiologic three-dimensional annular shape, but the annular motion was diminished. Conversely, MEMO could preserve both the anteroposterior movement and folding dynamics, but no three-dimensional restoration of the mitral annulus was obtained.
Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  35

Mesh:

Year:  2013        PMID: 24268749     DOI: 10.1016/j.athoracsur.2013.09.077

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  7 in total

1.  The choice of mitral annuloplastic ring-beyond "surgeon's preference".

Authors:  Song Wan; Alex P W Lee; Chun-Na Jin; Randolph H L Wong; Herman H M Chan; Calvin S H Ng; Innes Y P Wan; Malcolm J Underwood
Journal:  Ann Cardiothorac Surg       Date:  2015-05

2.  Annular dynamics after mitral valve repair with different prosthetic rings: A real-time three-dimensional transesophageal echocardiography study.

Authors:  Hiroyuki Nishi; Koichi Toda; Shigeru Miyagawa; Yasushi Yoshikawa; Satsuki Fukushima; Masashi Kawamura; Daisuke Yoshioka; Tetsuya Saito; Takayoshi Ueno; Toru Kuratani; Yoshiki Sawa
Journal:  Surg Today       Date:  2015-12-21       Impact factor: 2.549

3.  Physiological mitral annular dynamics preserved after ring annuloplasty in mid-term period.

Authors:  Masaaki Ryomoto; Masataka Mitsuno; Mitsuhiro Yamamura; Hiroe Tanaka; Naosumi Sekiya; Hisashi Uemura; Ayaka Sato; Daisuke Ueda; Yuji Miyamoto
Journal:  Gen Thorac Cardiovasc Surg       Date:  2017-08-08

4.  Comparison of saddle-shape flexibility and elliptical-shape stability between Cosgrove-Edwards and Memo-3D annuloplasty rings using three-dimensional analysis software.

Authors:  Akira Tsuneto; Kiyoyuki Eishi; Takashi Miura; Kazuyoshi Tanigawa; Seiji Matsukuma; Takako Minami; Yuji Koide; Satoshi Ikeda; Hiroaki Kawano; Koji Maemura
Journal:  Gen Thorac Cardiovasc Surg       Date:  2016-04-06

5.  Mitral annuloplasty ring design and selection: Complete semi-rigid is best.

Authors:  Taweesak Chotivatanapong
Journal:  JTCVS Tech       Date:  2021-10-22

6.  Posterior mitral annuloplasty for enhancing mitral leaflet coaptation: using a strip designed for placement in the posterior annulus.

Authors:  Jong Hun Kim; Kyung Hwa Kim; Jong Bum Choi; Ja Hong Kuh
Journal:  J Cardiothorac Surg       Date:  2015-11-13       Impact factor: 1.637

7.  Three-dimensional dynamic morphology of the mitral valve in different forms of mitral valve prolapse - potential implications for annuloplasty ring selection.

Authors:  Astrid Apor; Anikó Ilona Nagy; Attila Kovács; Aristomenis Manouras; Péter Andrássy; Béla Merkely
Journal:  Cardiovasc Ultrasound       Date:  2016-08-15       Impact factor: 2.062

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.