| Literature DB >> 24263560 |
Marta Cavagnaro1, Erika Pittella, Stefano Pisa.
Abstract
In this paper the propagation of a UWB pulse into a layered model of the human body is studied to characterize absorption and reflection of the UWB signal due to the different body tissues. Several time behaviours for the incident UWB pulse are considered and compared with reference to the feasibility of breath and heartbeat activity monitoring. Results show that if the UWB source is placed far from the human body, the reflection coming from the interface between air and skin can be used to detect the respiratory activity. On the contrary, if the UWB source is placed close to the human body, a small reflection due to the interface between the posterior lung wall and the bone, which is well distanced in time from the reflections due to the first layers of the body model, can be used to detect lung and heart changes associated with the cardio-respiratory activity.Entities:
Mesh:
Year: 2013 PMID: 24263560 DOI: 10.1088/0031-9155/58/24/8689
Source DB: PubMed Journal: Phys Med Biol ISSN: 0031-9155 Impact factor: 3.609