Literature DB >> 24262029

Radioisotope blood volume measurement in hemodialysis patients.

Sonika Puri1, Jun-Ki Park, Frank Modersitzki, David S Goldfarb.   

Abstract

Accurate assessment of blood volume (BV) may be helpful for prescribing hemodialysis (HD) and for reducing complications related to hypovolemia and volume overload. Monitoring changes in relative BV (RBV) using hematocrit, e.g., Crit-Line Monitor (CLM-III), an indirect method, cannot be used to determine absolute BV. We report the first study of BV measurement for assessing volume status in HD patients using the indicator dilutional method. Ten adult HD patients were enrolled in this prospective observational study. BV measurement was performed before and after HD using BV analysis (BVA)-100 (Daxor Corporation, New York, NY, USA). BVA-100 calculates BV using radiolabeled albumin (Iodine-131) followed by serial measures of the radioisotope. Fluid loss from the extravascular space was calculated by subtracting the change in BV from total weight loss. Intradialytic changes in RBV were measured by CLM-III. Eight out of 10 cases had significant hypervolemia, two cases were normovolemic. The range of BV variation from predicted normal was 156 to 1990 mL. Significant inter-individual differences in extravascular space fluid loss ranged from 54% to 99% of total weight loss. Spearman correlation showed a good correlation in the measurement of RBV by BVA-100 and CLM-III in 8 out of 10 patients (r(2) = 0.64). BV measurement using BVA-100 is useful to determine absolute BV as well as changes in BV and correlates reasonably well with CLM-III measurements. Individual refilling ability can be determined as well. This may prove useful in prescribing and monitoring ultrafiltration rates, establishment of optimal BV in HD patients and reducing morbidity and mortality associated with chronic HD.
© 2013 International Society for Hemodialysis.

Entities:  

Keywords:  Blood volume determination; absolute blood volume; dry weight; hemodialysis; ultrafiltration

Mesh:

Substances:

Year:  2013        PMID: 24262029     DOI: 10.1111/hdi.12105

Source DB:  PubMed          Journal:  Hemodial Int        ISSN: 1492-7535            Impact factor:   1.812


  5 in total

1.  Concordance of absolute and relative plasma volume changes and stability of Fcells in routine hemodialysis.

Authors:  Daniel Schneditz; Werner Ribitsch; Gernot Schilcher; Matthias Uhlmann; Yossi Chait; Vanessa Stadlbauer
Journal:  Hemodial Int       Date:  2015-08-05       Impact factor: 1.812

2.  A Numerical Model of Blood Flow Velocity Measurement Based on Finger Ring.

Authors:  Fu Yusheng; Qiyu Wang; Jianbo Yi; Dan Song; Xin Xiang
Journal:  J Healthc Eng       Date:  2018-10-03       Impact factor: 2.682

3.  Red blood cell volume is not decreased in ESA-naive anemic chronic kidney disease patients.

Authors:  Carsten Lundby; Belen Ponte; Anne-Kristine Lundby; Paul Robach; Sophie de Seigneux
Journal:  Physiol Rep       Date:  2018-11

4.  Blood volume analysis as a guide for dry weight determination in chronic hemodialysis patients: a crossover study.

Authors:  Line Malha; Hasan Fattah; Frank Modersitzki; David S Goldfarb
Journal:  BMC Nephrol       Date:  2019-02-11       Impact factor: 2.388

5.  Feasibility of Dialysate Bolus-Based Absolute Blood Volume Estimation in Maintenance Hemodialysis Patients.

Authors:  Simon Krenn; Michael Schmiedecker; Daniel Schneditz; Sebastian Hödlmoser; Christopher C Mayer; Siegfried Wassertheurer; Haris Omic; Eva Schernhammer; Peter Wabel; Manfred Hecking
Journal:  Front Med (Lausanne)       Date:  2022-02-10
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.