Reliability of Ultrasound Imaging of the Transversus Deep Abdominial, Internal Oblique and External Oblique Muscles of Patients with Low Back Pain Performing the Drawing-in Maneuver.

Sung Doo Park1.   

Abstract

[Purpose] The purpose of this study was to investigate the reliability of ultrasound imaging (USI) measurements of muscle thicknesses of patients with low back pain (LBP) performing the abdominal drawing-in maneuver (ADIM) [Subjects] Twenty patients with LBP were the subjects. [Methods] Muscle thickness measurements of transversus abdominis (Tra), internal obliques (IO), and external obliques (EO) muscles were measured using ultrasound imaging at rest and during performance of the ADIM.
[Results] The intra-examiner reliability estimates ranged from 0.55 to 0.97 in the rest position, and from 0.82 to 0.95 during ADIM. The inter-examiner reliability estimates ranged from 0.77 to 0.98 in the rest position, and from 0.86 to 0.98 during ADIM.
[Conclusion] ADIM thickness measurements of the TrA, IO, and EO muscles in patients with LBP based on the mean of 2 measures are highly reliable when taken by a single examiner and adequately reliable when taken by different examiners.

Entities:  

Keywords:  Abdominal drawing-in maneuver; Reliability; Ultrasound imaging

Year:  2013        PMID: 24259867      PMCID: PMC3820403          DOI: 10.1589/jpts.25.845

Source DB:  PubMed          Journal:  J Phys Ther Sci        ISSN: 0915-5287


INTRODUCTION

Low back pain (LBP) is one of the major health problems in western industrial societies with a life time prevalence of 84%1). One hypothesis for the development of LBP is that there is a dysfunction in the control of the abdominal and back muscles2). Richardson et al.3) suggest that this change in spinal control is due in part to dysfunction in local segmental muscles, such as the transversus abdominis. Most reliability studies have used a volitional task known as the abdominal drawing-in maneuver (ADIM)4, 5). Two aspects of muscle function that can be assessed using imaging techniques are muscle size (MRI, CT, ultrasound imaging) and muscle contraction (ultrasound imaging). The clinical relevance of these techniques is that they allow documentation of morphology and dynamic muscle function in both healthy subjects and those with acute and chronic low back pain6). Hodges et al.7) found strong correlations between muscle thickness changes of TrA and IO, and EMG activity at less than 20% of maximum voluntary contraction, but found no correlation for EO. Hodges and Richardson suggested using rehabilitative ultrasound imaging, a non-invasive and low-cost method, to observe the changes in the deep abdominal muscles8). However, there exist no previous studies of USI of the Tra, IO and EO muscles. The purpose of this study was to assess the intra- and inter-rater reliabilities of TrA, IO and EO ultrasound image (USI) measures in a suitable sample of subjects with LBP (n =20) using the generalizability theory as a framework .

SUBJECTS AND METHODS

A convenience sample of 20 LBP subjects (mean ±SD age = 28.83 ±11.13 years, height = 166.83 ±12.50 cm, weight = 61.17 ±9.60 kg, duration = 13.65 ±10.24 months) volunteered for this study at a local orthopedic clinic. Subjects had pain scores ranging from 5 –7 on a visual analogue scale, and scores of 40–60% on the Korean version of the Oswestry disability index. LBP was defined as current symptoms of pain and/or numbness between the twelfth rib and buttocks with or without symptoms in one or both legs that limited function9). Participants were excluded if they had received lumbar surgery were unable to lie prone or supine for a minimum of 20 minutes or presented with potentially serious conditions such as cauda equina syndrome, major or rapidly progressing neurologic deficit, fracture, cancer, infection, or systemic diseases. This study used ADIM to draw in and hold the lower abdomen at maximum expiration in a supine position. Verbal instructions for the ADIM were “Draw your belly inward and upward while breathing normally, then hold the contraction for 10 seconds.” ADIM was performed 3 times, with 10 second rest periods10). Before progressing to the main experiment, the subjects were educated in the method of ADIM and practiced 3 sets to decrease errors arising from incorrect performance. Rest and ADIM thicknesses of the TrA, IO and EO were obtained using a LOGIQ P5(GE Healthcare, USA) with a 7.5-MHz linear probe. Conductive gel was placed between the transducer and subjects skin. The measurements were taken as described by Richardson et al. with the subjects in the supine hook lying position with the transducer placed just superior to the iliac crest along the axillary line11). The transducer head location was marked on the right-hand side of each subject midway between the lowest rib and the apex of the ilium. This has been shown to be the thickest point of the Tra, and demonstrates the clearest simultaneous images of Tra, IO and EO12). The thickness of each of the 3 muscles (TrA, IO, and EO muscles) was measured at the center line of the image. The average of the 3 trials was used in the analysis. In processing data, the version 12.0 program was used. In order to assess the intra-examiner and inter-examiner of the ultrasound imaging intra class coefficients (ICC) were computed. ICC intraclass correlation coefficient; CI confidence interval; SEM standard error of measurement ICC intraclass correlation coefficient; CI confidence interval; SEM standard error of measurement

RESULTS

The intra-rater reliabilities of measurements of Tra, IO and EO were assessed at Rest and during ADIM with subjects in the hook-lying position, Tra at rest had the lowest ICC, 0.55, and EO at rest had the highest ICC, 0.97. Standard error (SEM) ranged from 0.14 to 0.50. For the ADIM, Tra also had the lowest ICC, 0.82, and EO also had the highest ICC, 0.95. SEM ranged from 0.28 to 0.61 (Table 1).
Table 1.

Intra-rater reliabilities of USI measurements of the Tra, IO and EO muscles

MuscleStateMean±SD (mm)ICC (95% CI)SEM (mm)
Session 1Session 2
TraRest (supine)3.02±0.653.29±0.960.55 (0.15–0.79)0.14
Contracted (ADIM)4.49±1.274.62±1.160.82 (0.60–0.92)0.28
IORest (supine)7.61±2.247.76±2.380.92 (0.82–0.97)0.50
Contracted (ADIM)9.16±2.759.43±3.130.94 (0.86–0.97)0.61
EORest (supine)5.09±1.755.05±1.990.97 (0.93–0.98)0.39
Contracted (ADIM)4.16±1.344.00±1.360.95 (0.87–0.98)0.30

ICC intraclass correlation coefficient; CI confidence interval; SEM standard error of measurement

The intra-rater reliability was assessed with Rater1, Rater2 and Rater3, three physical therapists with over 10 years of clinical experience. At rest, the ICCs of Tra, IO and EO ranged from 0.77–0.98 displaying a high level of reliability for Rest. SEM ranged from 0.15 to 0.27. During ADIM, the ICCs ranged from 0.86–0.98 indicating a high level of reliability. SEM ranged from 0.20 to 0.68 (Table 2).
Table 2.

Inter-rater reliabilities of USI measurements of the Tra, IO and EO muscles

MuscleStateMean±SD (mm)ICC (95% CI)SEM (mm)
Rater1Rater2Rater3
TraRest (supine)3.04±0.682.93±0.703.08±0.680.77 (0.59–0.89)0.15
Contracted (ADIM)4.59±1.104.70±1.144.51±1.240.90 (0.81–0.95)0.24
IORest (supine)7.92±2.188.04±2.287.72±2.330.98 (0.95–0.99)0.27
Contracted (ADIM)9.72±3.069.94±2.989.38±3.100.98 (0.97–0.99)0.68
EORest (supine)5.05±1.245.20±1.244.89±1.240.86 (0.73–0.93)0.27
Contracted (ADIM)3.84±0.933.71±0.973.69±0.990.86 (0.74–0.94)0.20

ICC intraclass correlation coefficient; CI confidence interval; SEM standard error of measurement

DISCUSSION

In this study of 20 male and female adults with low back pain, the reliability of USI was assessed using an inter-examiner and intra-examiner test-retest method for measurements of Tra, IO and EO at rest and during ADIM in a supine position. This was conducted through comparison thickness of Tra, IO and EO which used a base of lumbar stabilizer. Many previous studies have conducted investigations of ultrasound imaging of Tra, IO and EO. Critchley et al.12) reported abdominal muscle contraction thickness of chronic LBP patients was reduced compared to healthy subjects during the ADIM in a cress-sectional study. Hides et al.13) reported the reduced IO contraction thickness in a US saple population may represent a clinically relevant finding, as compared to healthy subjects, increased IO muscle activity with increasing load is reported in LBP patients. Several reliability studies have investigated the ultrasound imaging of the Tra and lumbar multifidus muscle14). Most of these studies have shown very high reliabilities (ICC>0.90) and good percision. The results of our present study are in agreement with these of these previous studies. Inter-rater reliability was better than intra-rater reliability. Consequently, it is much better to use three raters to make ultrasound image measures. In the present study, the intra-rater measurement errors were possibly greater than in previous studies because the raters carried out measures during different sessions, although within the same day. In this study, even though the factors mentioned above were not completely controlled, the USI measurement of Tra, IO and EO at rest and during ADIM was reliable and offers empirical information about the abdominal muscle thicknesses of low back pain patients.
  10 in total

1.  Measurement of muscle contraction with ultrasound imaging.

Authors:  P W Hodges; L H M Pengel; R D Herbert; S C Gandevia
Journal:  Muscle Nerve       Date:  2003-06       Impact factor: 3.217

2.  The stabilizing system of the spine. Part I. Function, dysfunction, adaptation, and enhancement.

Authors:  M M Panjabi
Journal:  J Spinal Disord       Date:  1992-12

3.  Altered response of the anterolateral abdominal muscles to simulated weight-bearing in subjects with low back pain.

Authors:  Julie A Hides; Daniel L Belavý; Lana Cassar; Michelle Williams; Stephen J Wilson; Carolyn A Richardson
Journal:  Eur Spine J       Date:  2008-11-18       Impact factor: 3.134

Review 4.  A systematic review of the reliability of rehabilitative ultrasound imaging for the quantitative assessment of the abdominal and lumbar trunk muscles.

Authors:  Jeffrey J Hebert; Shane L Koppenhaver; Eric C Parent; Julie M Fritz
Journal:  Spine (Phila Pa 1976)       Date:  2009-11-01       Impact factor: 3.468

5.  Inefficient muscular stabilization of the lumbar spine associated with low back pain. A motor control evaluation of transversus abdominis.

Authors:  P W Hodges; C A Richardson
Journal:  Spine (Phila Pa 1976)       Date:  1996-11-15       Impact factor: 3.468

6.  Rapid atrophy of the lumbar multifidus follows experimental disc or nerve root injury.

Authors:  Paul Hodges; Allison Kaigle Holm; Tommy Hansson; Sten Holm
Journal:  Spine (Phila Pa 1976)       Date:  2006-12-01       Impact factor: 3.468

Review 7.  Classification of low back-related leg pain--a proposed patho-mechanism-based approach.

Authors:  Axel Schäfer; Toby Hall; Kathy Briffa
Journal:  Man Ther       Date:  2007-12-31

8.  Reliability of rehabilitative ultrasound imaging of the transversus abdominis and lumbar multifidus muscles.

Authors:  Shane L Koppenhaver; Jeffrey J Hebert; Julie M Fritz; Eric C Parent; Deydre S Teyhen; John S Magel
Journal:  Arch Phys Med Rehabil       Date:  2009-01       Impact factor: 3.966

9.  The effect of chronic low back pain on size and contraction of the lumbar multifidus muscle.

Authors:  Tracy L Wallwork; Warren R Stanton; Matt Freke; Julie A Hides
Journal:  Man Ther       Date:  2008-11-21

Review 10.  Reproducibility of rehabilitative ultrasound imaging for the measurement of abdominal muscle activity: a systematic review.

Authors:  Leonardo Oliveira Pena Costa; Chris G Maher; Jane Latimer; Rob J E M Smeets
Journal:  Phys Ther       Date:  2009-06-11
  10 in total
  8 in total

1.  ULTRASOUND IMAGING MEASUREMENT OF THE TRANSVERSUS ABDOMINIS IN SUPINE, STANDING, AND UNDER LOADING: A RELIABILITY STUDY OF NOVICE EXAMINERS.

Authors:  Carrie W Hoppes; Aubrey D Sperier; Colleen F Hopkins; Bridgette D Griffiths; Molly F Principe; Barri L Schnall; Johanna C Bell; Shane L Koppenhaver
Journal:  Int J Sports Phys Ther       Date:  2015-11

2.  Abdomino-anal Dyscoordination in Defecatory Disorders.

Authors:  Sushmitha Grama Srinivasan; Anjani Muthyala; Mayank Sharma; Kelly Feuerhak; Andrea Boon; Kent R Bailey; Adil E Bharucha
Journal:  Clin Gastroenterol Hepatol       Date:  2021-12-08       Impact factor: 13.576

3.  Reliability of ultrasound imaging of the transversus abdominis muscle in asymptomatic subjects.

Authors:  Sin Ho Chung; Young Youl You
Journal:  J Phys Ther Sci       Date:  2015-05-26

4.  Ultrasound evaluation of the symmetry of abdominal muscles in mild adolescent idiopathic scoliosis.

Authors:  Paweł Linek; Edward Saulicz; Tomasz Wolny; Andrzej Myśliwiec; Anna Gogola
Journal:  J Phys Ther Sci       Date:  2015-02-17

5.  Effects of hip exercises for chronic low-back pain patients with lumbar instability.

Authors:  Sang Wk Lee; Suhn Yeop Kim
Journal:  J Phys Ther Sci       Date:  2015-02-17

6.  The accuracy of pain drawing in identifying psychological distress in low back pain-systematic review and meta-analysis of diagnostic studies.

Authors:  Lucia Bertozzi; Anna Rosso; Antonio Romeo; Jorge Hugo Villafañe; Andrew A Guccione; Paolo Pillastrini; Carla Vanti
Journal:  J Phys Ther Sci       Date:  2015-10-30

Review 7.  Improved perioperative analgesia with ultrasound-guided ilioinguinal/iliohypogastric nerve or transversus abdominis plane block for open inguinal surgery: a systematic review and meta-analysis of randomized controlled trials.

Authors:  Yuexiang Wang; Tao Wu; Marisa J Terry; Jason S Eldrige; Qiang Tong; Patricia J Erwin; Zhen Wang; Wenchun Qu
Journal:  J Phys Ther Sci       Date:  2016-03-31

8.  Ultrasound Imaging of the Abdominal Wall and Trunk Muscles in Patients with Achilles Tendinopathy versus Healthy Participants.

Authors:  Carlos Romero-Morales; Pedro Martín-Llantino; César Calvo-Lobo; Marta San-Antolín; Daniel López-López; María Blanco-Morales; David Rodríguez-Sanz
Journal:  Diagnostics (Basel)       Date:  2019-12-30
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.