Diode laser system for measurement of gaseous ammonia in ambient air.

F Cappellani1, G Melandrone, G Restelli.   

Abstract

The use of a second harmonic diode laser system for monitoring gaseous ammonia in tropospheric air is discussed. Using a 96 m White cell operated at 13 torr pressure in flow mode, a minimum detectable concentration lower than 1 ppbv was obtained.The NH3 mixing ratio was determined by simultaneous spectroscopic analysis of an atmospheric CO2 line used as a built-in calibration standard.

Entities:  

Year:  1985        PMID: 24258033     DOI: 10.1007/BF00394068

Source DB:  PubMed          Journal:  Environ Monit Assess        ISSN: 0167-6369            Impact factor:   2.513


  12 in total

1.  Tunable diode laser systems for measuring trace gases intropospheric air.

Authors:  H I Schiff; D R Hastie; G I Mackay; T Iguchi; B A Ridley
Journal:  Environ Sci Technol       Date:  1983-08-01       Impact factor: 9.028

2.  Atmospheric pressure monitoring of trace gases using tunable diode lasers.

Authors:  D T Cassidy; J Reid
Journal:  Appl Opt       Date:  1982-04-01       Impact factor: 1.980

3.  Remote and cross-stack measurement of stack gas concentrations using a mobile FT-IR system.

Authors:  W F Herget
Journal:  Appl Opt       Date:  1982-02-15       Impact factor: 1.980

4.  Long-path monitoring: advanced instrumentation with a tunable diode laser.

Authors:  E D Hinkley; R T Ku; K W Nill; J F Butler
Journal:  Appl Opt       Date:  1976-07-01       Impact factor: 1.980

5.  AFGL trace gas compilation: 1982 version.

Authors:  L S Rothman; A Goldman; J R Gillis; R R Gamache; H M Pickett; R L Poynter; N Husson; A Chedin
Journal:  Appl Opt       Date:  1983-06-01       Impact factor: 1.980

6.  Application of tunable diode laser absorption for trace stratospheric measurements of HCl: laboratory results.

Authors:  A Fried; R Sams; W W Berg
Journal:  Appl Opt       Date:  1984-06-01       Impact factor: 1.980

7.  High sensitivity pollution detection employing tunable diode lasers.

Authors:  J Reid; J Shewchun; B K Garside; E A Ballik
Journal:  Appl Opt       Date:  1978-01-15       Impact factor: 1.980

8.  Absorption coefficients of various pollutant gases at CO(2) laser wavelengths; application to the remote sensing of those pollutants.

Authors:  A Mayer; J Comera; H Charpentier; C Jaussaud
Journal:  Appl Opt       Date:  1978-02-01       Impact factor: 1.980

9.  Optical feedback effects on the performance of Pb(1-x)Sn(x)Se semiconductor lasers.

Authors:  C N Harward; J M Hoell
Journal:  Appl Opt       Date:  1979-12-01       Impact factor: 1.980

10.  A kilometer pathlength Fourier-transform infrared system for the study of trace pollutants in ambient and synthetic atmospheres.

Authors:  E C Tuazon; R A Graham; A M Winer; R R Easton; J N Pitts; P L Hanst
Journal:  Atmos Environ       Date:  1978       Impact factor: 4.798

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.