Literature DB >> 20389829

Atmospheric pressure monitoring of trace gases using tunable diode lasers.

D T Cassidy, J Reid.   

Abstract

High-sensitivity measurements of infrared absorptions due to isolated lines broadened by air at atmospheric pressure are reported. Tunable diode lasers and harmonic techniques were employed to detect absorptions as small as 0.01% over path lengths up to 250 m through the open air. The limiting noise source is caused by a base line signal which varies with the optical alignment. The reported sensitivity is not a fundamental limit. Techniques for further increasing sensitivity are discussed.

Year:  1982        PMID: 20389829     DOI: 10.1364/AO.21.001185

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  7 in total

1.  Diode laser system for measurement of gaseous ammonia in ambient air.

Authors:  F Cappellani; G Melandrone; G Restelli
Journal:  Environ Monit Assess       Date:  1985-09       Impact factor: 2.513

2.  Towards a standard for the dynamic measurement of pressure based on laser absorption spectroscopy.

Authors:  K O Douglass; D A Olson
Journal:  Metrologia       Date:  2016-05-20       Impact factor: 3.157

3.  Rapid, time-division multiplexed, direct absorption- and wavelength modulation-spectroscopy.

Authors:  Alexander Klein; Oliver Witzel; Volker Ebert
Journal:  Sensors (Basel)       Date:  2014-11-14       Impact factor: 3.576

4.  Modulation Index Adjustment for Recovery of Pure Wavelength Modulation Spectroscopy Second Harmonic Signal Waveforms.

Authors:  Wei Wei; Jun Chang; Qiang Wang; Zengguang Qin
Journal:  Sensors (Basel)       Date:  2017-01-15       Impact factor: 3.576

5.  Reduction of Signal Drift in a Wavelength Modulation Spectroscopy-Based Methane Flux Sensor.

Authors:  Scott P Seymour; Simon A Festa-Bianchet; David R Tyner; Matthew R Johnson
Journal:  Sensors (Basel)       Date:  2022-08-17       Impact factor: 3.847

6.  Intensity-Stabilized Fast-Scanned Direct Absorption Spectroscopy Instrumentation Based on a Distributed Feedback Laser with Detection Sensitivity down to 4 × 10-6.

Authors:  Gang Zhao; Wei Tan; Mengyuan Jia; Jiajuan Hou; Weiguang Ma; Lei Dong; Lei Zhang; Xiaoxia Feng; Xuechun Wu; Wangbao Yin; Liantuan Xiao; Ove Axner; Suotang Jia
Journal:  Sensors (Basel)       Date:  2016-09-21       Impact factor: 3.576

7.  Novel Semi-Parametric Algorithm for Interference-Immune Tunable Absorption Spectroscopy Gas Sensing.

Authors:  Umberto Michelucci; Francesca Venturini
Journal:  Sensors (Basel)       Date:  2017-10-07       Impact factor: 3.576

  7 in total